Sponsored Content
Full Discussion: Fsck with SVM
Operating Systems Solaris Fsck with SVM Post 302577147 by vishalaswani on Monday 28th of November 2011 09:43:03 AM
Old 11-28-2011
Hello,

We don't run fsck on mounted filesystem.

In SVM, devices are not created the way you have mentioned, meta devices are named as d0, d1, d12 etc... 'd' followed by a number.

Consider the below example:

d11 - c0t0d0s0
d12 - c0t1d0s0

d10 is a mirrored metadevice with d11 and d12 as its sub mirror.

You will mount d10 after creating a filesystem on it for any use.

In case you want to run fsck on it or its sub mirrors, then you first need to unmount it and then run fsck accordingly.

fsck /dev/md/rdsk/d10
fsck /dev/md/rdsk/d11
fsck /dev/md/rdsk/d12

Hope this helps.

Regards,
Vishal
 

10 More Discussions You Might Find Interesting

1. Filesystems, Disks and Memory

fsck -y

Once in a while, I would think it advisable to run fsck -y to check the disk. Should I sign in as su or sudo? What is the difference and which is preferred? Thank you in Advance! (4 Replies)
Discussion started by: rpatrick
4 Replies

2. Solaris

fsck

OS: Solaris 5.8 Everytime I run fsck -y I get: FILE SYSTEM STATE IN SUPERBLOCK IS WRONG; FIX? yes Do I need to run fsck with the backup superblock option or is there some other option I should use. I have tried the format->analyze->read option but that does not report any corrupt blocks.... (5 Replies)
Discussion started by: run_time_error
5 Replies

3. UNIX for Dummies Questions & Answers

fsck - what should be done?

I want to use fsck to check and repair my linux system. When I use this command, what do I need to pay attention to or what should I do to make job running successfully. Thanks for your inputs for a newbie. (3 Replies)
Discussion started by: duke0001
3 Replies

4. Solaris

fsck -o

Hello I am getting this in dmesg: /mount1: unexpected free inode 1262865, run fsck(1M) -o f What are the options I should use with fsck? thanks (2 Replies)
Discussion started by: melanie_pfefer
2 Replies

5. UNIX for Dummies Questions & Answers

about fsck

i want to know what does it mean by doing a consistentcy check fsck on a disk and why journaling filesystems dont need to do it and what is meant by disk is in a consistent state when writing because entries are recorded in a journal and then to the metadata and then removed from journal (1 Reply)
Discussion started by: farhan_t49
1 Replies

6. Solaris

fsck issue

I am not able to boot into solaris. I am getting following message. The / file system (/dev/rdsk/c0t0d0s0) is being checked. Warning - Unable to repair the / filesystem. Run fsck manually(fsck -F ufs /dev/rdsk/c0t0d0s0). I ran fsck manually but it didn't work. Help from anyone would be... (1 Reply)
Discussion started by: likhitgatagat
1 Replies

7. Solaris

Urgent !! SVM, subdisks "UNEXPEXTED INCONSITENCY; RUN fsck MANUALLY

Hi, I am getting this error while server booting up, not sure how to fix this. Unable to mount these file systems /dev/md/rdsk/d51: No such device or address Can't open /dev/md/rdsk/d51: No such device or address /dev/md/rdsk/d51: CAN'T CHECK FILE SYSTEM. /dev/md/rdsk/d51: UNEXPECTED... (1 Reply)
Discussion started by: bobby320
1 Replies

8. Solaris

fsck - how to know if required or not

Hello Friends, My doubt is 1) How do we know if we need Fsck to run or not can we check using any switch so that we can know if our filesystem really requires to run fsck or not?? (2 Replies)
Discussion started by: saurabh84g
2 Replies

9. Solaris

unable to repair the / filesystem. Run fsck manually (fsck -F ufs /dev/rdsk/c1t0d0s0)

What can I fix this issue? I have ran below commands but everything is same.:confused: WARNING: Last shutdown is later than time on time-of-day chip: check date. The / file system (/dev/rdsk/c1t0d0s0) is being checked WARNING - unable to repair the / filesystem. Run fsck manually (fsck -F... (4 Replies)
Discussion started by: getrue
4 Replies

10. Solaris

Fsck in vxvm

Hi, When we are running fsck in vxvm FS within few sec it will completed even if data is more than 500GB or in TB also. compare to UFS FS in that it will take more time compare with vxvm.UFS check FS in block level. & then vvxm on where its checking the FS. Please explain. (1 Reply)
Discussion started by: tiger09
1 Replies
CCD(4)							   BSD Kernel Interfaces Manual 						    CCD(4)

NAME
ccd -- Concatenated Disk driver SYNOPSIS
device ccd DESCRIPTION
The ccd driver provides the capability of combining one or more disks/partitions into one virtual disk. This document assumes that you are familiar with how to generate kernels, how to properly configure disks and devices in a kernel configura- tion file, and how to partition disks. In order to compile in support for the ccd, you must add a line similar to the following to your kernel configuration file: device ccd # concatenated disk devices As of the FreeBSD 3.0 release, you do not need to configure your kernel with ccd but may instead use it as a kernel loadable module. Simply running ccdconfig(8) will load the module into the kernel. A ccd may be either serially concatenated or interleaved. To serially concatenate the partitions, specify the interleave factor of 0. Note that mirroring may not be used with an interleave factor of 0. There is a run-time utility that is used for configuring ccds. See ccdconfig(8) for more information. The Interleave Factor If a ccd is interleaved correctly, a ``striping'' effect is achieved, which can increase sequential read/write performance. The interleave factor is expressed in units of DEV_BSIZE (usually 512 bytes). For large writes, the optimum interleave factor is typically the size of a track, while for large reads, it is about a quarter of a track. (Note that this changes greatly depending on the number and speed of disks.) For instance, with eight 7,200 RPM drives on two Fast-Wide SCSI buses, this translates to about 128 for writes and 32 for reads. A larger interleave tends to work better when the disk is taking a multitasking load by localizing the file I/O from any given process onto a single disk. You lose sequential performance when you do this, but sequential performance is not usually an issue with a multitasking load. An interleave factor must be specified when using a mirroring configuration, even when you have only two disks (i.e., the layout winds up being the same no matter what the interleave factor). The interleave factor will determine how I/O is broken up, however, and a value 128 or greater is recommended. ccd has an option for a parity disk, but does not currently implement it. The best performance is achieved if all component disks have the same geometry and size. Optimum striping cannot occur with different disk types. For random-access oriented workloads, such as news servers, a larger interleave factor (e.g., 65,536) is more desirable. Note that there is not much ccd can do to speed up applications that are seek-time limited. Larger interleave factors will at least reduce the chance of having to seek two disk-heads to read one directory or a file. Disk Mirroring You can configure the ccd to ``mirror'' any even number of disks. See ccdconfig(8) for how to specify the necessary flags. For example, if you have a ccd configuration specifying four disks, the first two disks will be mirrored with the second two disks. A write will be run to both sides of the mirror. A read will be run to either side of the mirror depending on what the driver believes to be most optimal. If the read fails, the driver will automatically attempt to read the same sector from the other side of the mirror. Currently ccd uses a dual seek zone model to optimize reads for a multi-tasking load rather than a sequential load. In an event of a disk failure, you can use dd(1) to recover the failed disk. Note that a one-disk ccd is not the same as the original partition. In particular, this means if you have a file system on a two-disk mir- rored ccd and one of the disks fail, you cannot mount and use the remaining partition as itself; you have to configure it as a one-disk ccd. You cannot replace a disk in a mirrored ccd partition without first backing up the partition, then replacing the disk, then restoring the partition. Linux Compatibility The Linux compatibility mode does not try to read the label that Linux' md(4) driver leaves on the raw devices. You will have to give the order of devices and the interleave factor on your own. When in Linux compatibility mode, ccd will convert the interleave factor from Linux terminology. That means you give the same interleave factor that you gave as chunk size in Linux. If you have a Linux md(4) device in ``legacy'' mode, do not use the CCDF_LINUX flag in ccdconfig(8). Use the CCDF_NO_OFFSET flag instead. In that case you have to convert the interleave factor on your own, usually it is Linux' chunk size multiplied by two. Using a Linux RAID this way is potentially dangerous and can destroy the data in there. Since FreeBSD does not read the label used by Linux, changes in Linux might invalidate the compatibility layer. However, using this is reasonably safe if you test the compatibility before mounting a RAID read-write for the first time. Just using ccdconfig(8) without mounting does not write anything to the Linux RAID. Then you do a fsck.ext2fs (ports/sysutils/e2fsprogs) on the ccd device using the -n flag. You can mount the file system read-only to check files in there. If all this works, it is unlikely that there is a problem with ccd. Keep in mind that even when the Linux compatibility mode in ccd is working correctly, bugs in FreeBSD's ex2fs implemen- tation would still destroy your data. WARNINGS
If just one (or more) of the disks in a ccd fails, the entire file system will be lost unless you are mirroring the disks. If one of the disks in a mirror is lost, you should still be able to back up your data. If a write error occurs, however, data read from that sector may be non-deterministic. It may return the data prior to the write or it may return the data that was written. When a write error occurs, you should recover and regenerate the data as soon as possible. Changing the interleave or other parameters for a ccd disk usually destroys whatever data previously existed on that disk. FILES
/dev/ccd* ccd device special files SEE ALSO
dd(1), ccdconfig(8), config(8), disklabel(8), fsck(8), gvinum(8), mount(8), newfs(8) HISTORY
The concatenated disk driver was originally written at the University of Utah. BSD
August 9, 1995 BSD
All times are GMT -4. The time now is 01:26 PM.
Unix & Linux Forums Content Copyright 1993-2022. All Rights Reserved.
Privacy Policy