Sponsored Content
Full Discussion: Mount Emc Clones in VxVm
Operating Systems Solaris Mount Emc Clones in VxVm Post 302575172 by Tirmazi on Sunday 20th of November 2011 09:02:00 PM
Old 11-20-2011
Mount Emc Clones in VxVm

The Storage Admin presents a clone of a LUN, on the source side the device is under VxVM control, assuming that on the target side we have scanned the new cloned LUN at the OS level (solairs), from there on how do we initialize and mount the new volume.

Please give some guidence on this or a pointer to some examples.

I believe some of the System Admins use vxrecover for this.

Secondly, will the process be different in case of Snaps.

Regards
 

9 More Discussions You Might Find Interesting

1. HP-UX

is anybody using EMC symmetrix?

Hello, I'm looking for reference sites using HP-UX and EMC symmetrix disk. Then, May I ask you questions? (6 Replies)
Discussion started by: cooldugong
6 Replies

2. Solaris

Emc

Dear gentelmen kindly please update me me how can i know disks on EMC and get size for all disks on EMC? (1 Reply)
Discussion started by: magasem
1 Replies

3. HP-UX

Emc

Dear gentelmen kindly please update me how can i know disks on EMC and get size for all disks on EMC? (0 Replies)
Discussion started by: magasem
0 Replies

4. Solaris

Mount points of available Vxvm disks

I have situation where I want to know about all the vxvm mount points information on my solaris box, because after rebooting the server the few mount points are not mounted automatically because they where not copied in /etc/vfstab. So please help me out on the same.:( (0 Replies)
Discussion started by: nimish_mehta
0 Replies

5. Solaris

EMC Failover

Hi guys, I'm running vxdmp and powerpath at the same time. Vxdmp for internal disks and powerpath for external. The problem is that, on the failover tests which a fiber cable should be removed, the system cannot recognize the disks. Any hints on how to configure powerpath in order to... (4 Replies)
Discussion started by: glenioborges
4 Replies

6. Programming

Wait for clones

Hi, I have a methode creating several clones with the following flags: CLONE_VM | CLONE_THREAD | CLONE_SIGHAND How to tell the parent process to wait for the clones' completion? pid = clone( ...) waitpid(pid, NULL , 0) always returns me -1 waitpid(-1, NULL, 0) does the same. (1 Reply)
Discussion started by: The-Forgotten
1 Replies

7. Solaris

Solaris/vxvm/EMC Lun configuration

Hello all, i try to allocate the same LUN to two server (or more in the future) i use solaris 10, vxvm (vxfs) for data and solaris zones and EMC DMX-4, i try to migrate solaris zones between servers in case of problem. and this is what i want to do - affect LUN to srv00124 and srv10155 -... (5 Replies)
Discussion started by: mat_solaris
5 Replies

8. UNIX for Dummies Questions & Answers

Updating git clones

Hi, I'm fairly new to the git command and I'm trying to figure out how to check if your local clone is up to date with the master. I know you can do the same thing on packages with apt-get by using update and then upgrade. Is there something similar with git? (0 Replies)
Discussion started by: silverdust
0 Replies

9. Programming

Chinese Arduino UNO Clones - The Wavgat versus the generic UNO R3 Clone - The Winner Is?

Waiting for more fun Ardunio parts from AliExpress, I decided to test two cheap Chinese Arduino UNO clones. The Arduino UNO R3 (CH340G) MEGA328P The Wavgat UNO R3 (CH340G) MEGA328P Both of these Chinese Ardunio clones sell for about $3 USD, delivered to your door. The bottom line is... (0 Replies)
Discussion started by: Neo
0 Replies
format(1M)																format(1M)

NAME
format - format an HP SCSI disk array LUN SYNOPSIS
device_file DESCRIPTION
formats one LUN of the HP SCSI disk array associated with device file, device_file. The format will usually be a soft or zeroing format, in which the controller writes zeroes to the data area and parity area, if any, of the LUN. NOTE: The above should always be true of a sub-LUN, but the controller might decide, based on certain conditions, to do a full format of a regular LUN, which consists of sending a mode select and a media initialization command to the physical drive(s) in question, fol- lowed by zeroing the data and parity area, if any. The conditions which will cause a full format to be done are as follows: 1. The controller received a Mode Select command which requires a drive sector size change. 2. The controller received a Mode Select command which changed a parameter in the Format Device Page(0x03). 3. The LUN contains one or more failed drives. In this case only a certain subset of the drives containing the failed drives will be formatted. 4. Either the FmtData or the CmpLst bit in the Format Unit CDB is set. RETURN VALUE
returns the following values: 0 Successful completion. -1 Command failed. DIAGNOSTICS AND ERRORS
Errors can originate from problems with: o o SCSI (device level) communications o system calls Error messages generated by format: An error in command syntax has occurred. Enter command again with all required arguments, in the order shown. To ensure that does not modify a disk array that is being used by another process, attempts to obtain exclusive access to the disk array. If the disk array is already opened by another process (for example, LVM -- the Logical Volume Manager), a "" error message is returned by the driver. To eliminate the "" condition, determine what process has the device open. In the case of LVM, it is necessary to deactivate the volume group containing the array before formatting array LUNs (see vgchange(1M)). The LUN number, which is derived from the device file name, is out of range. The addressed LUN is not configured, and thus is not known to the array controller. Utilities must be able to open the device file for raw access. The device being addressed is not an HP SCSI disk array. SCSI (device level) communication errors: Sense data associated with the failed operation is printed. Error messages generated by system calls: uses the following system calls: and Documentation for these HP-UX system calls contains information about the specific error conditions associated with each call. does not alter the value of The interpretation of for printing purposes is performed by the system utility EXAMPLES
To format the HP SCSI disk array LUN on a Series 800: WARNING
The command will destroy all user data on the addressed LUN. DEPENDENCIES
The HP C2425 and HP C2427 disk arrays are only supported on Series 700 systems running HP-UX version 9.0X. The HP C2430 disk array is supported on Series 700 and 800 systems running HP-UX versions 9.0X and 10.0X. AUTHOR
was developed by HP. format(1M)
All times are GMT -4. The time now is 04:05 AM.