11-13-2011
Quote:
Originally Posted by
nagarjunatula
hi polar,
what is ur server model?
depends upon the model we have to configure.if it is power6 520 then k.
is ur server is managed through hmc?
if it is connected, select the server and go to hardware information.tjhere you will locate the physical ethernet ports, then select the port and configure it.set the promiscous mode for the port which u have selected.
Power model 720 with HMC.
Means that i configure the particular client LPARs for particular physical port(ent0, ent1, ent2, ent3) on 'Promiscous LPAR'? so that 4 set of SEA configure can be used without any problems?
(p.s : This adapter card is not HEA)
Last edited by polar; 11-13-2011 at 07:07 AM..
Reason: correction
10 More Discussions You Might Find Interesting
1. Shell Programming and Scripting
Okay, not sure if it can be done, I would think it could be done and I'm just having a hard time with it.
fun_close_wait(){
ipVar="${1} ${2}"
portVar=`cat "${5}" | cut -d' ' -f 1`
for ip in $ipVar
do
for port in $portVar
do
netstatVar=`netstat -n | grep... (4 Replies)
Discussion started by: cbo0485
4 Replies
2. AIX
I am trying to create a SEA on a LHEA port and it gives me error
lsdev -Cc adapter:
ent0 logical host ethernet port (l-hea)
ent1 virtual I/O ethernet adapter
mkvdev -sea ent0 -vadapter ent1 -default ent1 -defaultid 199
method error (/usr/lib/methods/cfgsea):
Failed to configure SEA... (0 Replies)
Discussion started by: filosophizer
0 Replies
3. AIX
Hi Guys,
I'm getting the below error while trying to create a SEA adapter in VIOS
$ mkvdev -sea ent0 -vadapter ent2 -default ent2 -defaultid 1
... (4 Replies)
Discussion started by: kkeng808
4 Replies
4. AIX
Hi all,
I set up the following configuration on my system:
- An LPar with a virtual adapter, first one with a vlan id=703 and id port=13.
- The first adapter have to connect to a VIOS in which i configured an SEA.
So, the VA is set up on interface ent2, SEA on ent29 (by linking a... (0 Replies)
Discussion started by: idro
0 Replies
5. Linux
Hi,
Can we set password for linux in non-interactive mode.
I didn't find suitable option for this in man page.
If we wnter "passwd" command, it will tell "Enter password" and "Re-enter password". i wanted to run this step in a script, and i don't want to use "expect" so i am looking for a single... (8 Replies)
Discussion started by: successlin
8 Replies
6. AIX
I am trying to install a VIOS pair with a load-sharing SEA adapter, following this recipe from Developerworks. Without load-sharing everything went fine and worked as expected, but somehow i am a bit lost and the first tries with "ha_mode=sharing" didn't work at all.
Here is the situation:
I... (6 Replies)
Discussion started by: bakunin
6 Replies
7. AIX
Hello,
Lets say for simplicity that I do not use any vlan config inside my server - one lpar group use hea physical port1, another group hea physical port2. Physical port1 configured as vlan1 on external switch, physical port2 as vlan2.
What is the common practice - should I isolate my vios... (0 Replies)
Discussion started by: vilius
0 Replies
8. AIX
i want configure a SEA over my vios ,
i have a message error :
Method error (/usr/lib/methods/cfgsea):
Failed to configure SEA with return code 1 and SEA-specific error code 10:
Detailed info: Setting real adapter ent1 in promiscuous mode failed... (5 Replies)
Discussion started by: hedou
5 Replies
9. AIX
hello,
what will happen if i try to move sea of my 1 vio server to standby( using chdev command), when sea of other vio server is already in standby mode? (1 Reply)
Discussion started by: amvineeth
1 Replies
10. AIX
Hello,
I found that the packet counts given by entstat -d SEA is not the same as the total of the packet counts given by seastat -d SEA for the same interval of time.
Do anyone have an explanation for the difference. We recently got a recommendation that the throughput on an SEA should not... (5 Replies)
Discussion started by: N8R
5 Replies
LEARN ABOUT REDHAT
ipx_cmd
IPX_CMD(8) System Manager's Manual IPX_CMD(8)
NAME
ipx_cmd - bridge between Novell's SCMD driver and local IPX network
SYNOPSIS
ipx_cmd -A server name [ -l local interface name ]
DESCRIPTION
ipx_cmd moves packets from tapN to server and vice versa. It is something like IPX Tunnel, but it uses Novell Netware 5 server Compatibil-
ity Mode Driver (AKA Migration Agent) on the other end of wire. You must first configure your kernel tapN device with IPX EthernetII frame
and with network number set up on server (you can use kernel autodetection).
OPTIONS
-A server name
This is IP name of compatibility mode server. You can use DNS name or dotted quad to specify server address.
-l local interface name
This allows you to specify, which of your IP addresses should be used as IP address of client side of CMD driver. You must configure
your tapN device with hardware address 7E:01:AA:BB:CC:DD, where AA:BB:CC:DD is your IP address in hexa.
EXAMPLE
If you are on server platan.vc.cvut.cz (147.32.240.81) and your migration agent runs on server boris.vc.cvut.cz, you can configure your
system with:
insmod ethertap
ifconfig tap0 hw ether 7E:01:93:20:F0:51 up
ipx_interface add -p tap0 EtherII
ipx_cmd -A boris.vc.cvut.cz -l 147.32.240.81 &
BUGS
This program was written to satisfy my own needs and should be really improved. At least it should configure tap interface itself.
AUTHOR
Petr Vandrovec <vandrove@vc.cvut.cz>
ipx_cmd IPX Utilities IPX_CMD(8)