Sponsored Content
Special Forums Hardware StorageTek 2540 battery failed Post 302565947 by DukeNuke2 on Wednesday 19th of October 2011 06:52:55 AM
Old 10-19-2011
in case of a power outage you will lose any data in cache which isn't (yet) written to disks... a new battery would be the safer way!
 

10 More Discussions You Might Find Interesting

1. Solaris

Sun Sparc T2000 + StorageTek 2540 - Help, I'm lost

I have a Sun Sparc T2000 (Solaris 10 05-08) and have installed a PCI-X 4GB Single Port HBA card in it. I have one StorageTek 2540 array that I would like to connect to the T2000. For the moment it would be a single path connection, but I've ordered a 2nd HBA, so eventually it would be... (4 Replies)
Discussion started by: soliberus
4 Replies

2. Solaris

One StorageTek 6140 vs Two (2) 2540 's?

We're moving our production 3510FC to development, so we need to replace the production 3510FC. The 6140 is nice, but pricey. Here's the question: Would two 2540's (RAID 10) be 'faster' than one 3510? (RAID 10) and faster than one 6140 (RAID 10)? One StoregeTek 6140 (16x72GB 15k rpm fc-al... (12 Replies)
Discussion started by: buddhavelvet
12 Replies

3. Filesystems, Disks and Memory

Configure large volume on Sun StorageTek 2540 array

Hi, We have 12x1TB SATA disks in our array and I need to create 10TB volume. I defined new storage profile on array and when I tried to add volume, I faced with ~2TB limit for new volumes. I didn't find how to set another limit on my storage profile. Is there is a way to configure one large... (3 Replies)
Discussion started by: Sapfeer
3 Replies

4. Solaris

Sun StorageTek 2540 - shutdown matrix

Hi, I have a simple question on how to correctly disable the matrix? Looking for the Common Array Manager and I do not see this option... Thank for help (3 Replies)
Discussion started by: bieszczaders
3 Replies

5. Solaris

Storagetek 2540

Hi peeps, Was wondering if anyone can help me, got a couple of storagetek 2540's that I need to configure. Trouble is I think they were brought as second user as all that came with them was cables. Does anyone know how to configure them (i.e. create raid sets and map to Luns and present... (1 Reply)
Discussion started by: callmebob
1 Replies

6. Hardware

Storagetek 2540

Hello all ! I am a beginner about system and networking , and after some research on internet , i didn't find any relevant information , so i post here , if someone have an experience with this kind of material or if some documentation about how to connect my storage device on my server. I... (2 Replies)
Discussion started by: acorradi
2 Replies

7. Solaris

SUN 6540 Array with failed controller battery

Can someone point me to a procedure detailing the replacement of a failed battery in a SUN 6540 controller. Or describe the procedure. Thanks (1 Reply)
Discussion started by: USFE
1 Replies

8. Hardware

Storagetek 2540

Hi Guys and Gals, Wionder if you could help me, got a problem with a controller on a storagetek 2540, dead when fully powered up but if you reboot, it is ok for a couple of seconds (and you can ping it). Then once the array is fully up, it goes faulty and is un-pingable. Had anyone... (4 Replies)
Discussion started by: callmebob
4 Replies

9. Solaris

StorageTek 2540 SAN array

Bought a Sun StorageTek 2540 SAN array a few years ago from a company that was going out of business. When we first set it up, we were able to get all the software (Common Array Manager) and firmware directly from Sun. We just upgraded the drives, but the array is too large for the firmware. Now... (6 Replies)
Discussion started by: edison303
6 Replies

10. Solaris

Server M4000 server lost connectivity to storagetek 2540

Hi Guys, I have situation here ... server M4000 server lost connectivity to storagetek 2540 , storagetek 2540 unable to be ping.From DAS URL the storage is undetected. Any idea why this is happening. Please share. Thank you. Raj (1 Reply)
Discussion started by: muralirajah
1 Replies
INITTODR(9)						   BSD Kernel Developer's Manual					       INITTODR(9)

NAME
inittodr -- initialize system time SYNOPSIS
void inittodr(time_t base); DESCRIPTION
The inittodr() function determines the time and sets the system clock. It tries to pick the correct time using a set of heuristics that examine the system's battery-backed clock and the time reported by the file system, as given in base. Those heuristics include: o If the battery-backed clock has a valid time, and is not significantly behind the time provided by base, it is used. o If the battery-backed clock does not have a valid time, or is significantly behind the time provided in base, and the time provided in base is within reason, base is used as the current time. o If the battery-backed clock appears invalid, and base appears non-sensical or was not provided (was given as zero), an arbitrary base (typically some time within the same year that the kernel was last updated) will be used. Once a system time has been determined, it is stored in the time variable. DIAGNOSTICS
The inittodr() function prints diagnostic messages if it has trouble figuring out the system time. Conditions that can cause diagnostic mes- sages to be printed include: o There is no battery-backed clock present on the system. o The battery-backed clock's time appears nonsensical. o The base time appears nonsensical. o The base time and the battery-backed clock's time differ by a large amount. SEE ALSO
clock_ymdhms_to_secs(9), resettodr(9), time_second(9) BUGS
Some systems use heuristics for picking the correct time that are slightly different. BSD
September 6, 2006 BSD
All times are GMT -4. The time now is 04:00 PM.
Unix & Linux Forums Content Copyright 1993-2022. All Rights Reserved.
Privacy Policy