Special Forums Hardware StorageTek 2540 battery failed Post 302565924 by buyantugs on Wednesday 19th of October 2011 06:13:30 AM
Old 10-19-2011
Error StorageTek 2540 battery failed

Hi all,

My Sun StorageTek 2540 have redundant batteries, but a battery was failed.

Code:
# /opt/SUNWstkcam/bin/sscs list -d MyStorage1 fru
Name                       FRU         Alarm    State               Status Revision    Unique Id
-------------------------- ----------- -------- ------------------- ------ ----------- ----------------------------
Tray.85.Battery.A          Battery     -        Enabled             OK     N/A         SY81500764SA
Tray.85.Battery.B          Battery     Critical Enabled but Offline Error  N/A         SY81500830SA

After the battery failure, the server read/write performance was down (I assume)!

I read some doc from internet and I found a reason to performance down when storage array battery failed. A guy tell me you should change "Write Cache without Batteries" option to ENABLE on the storage volume using SSCS CLI utility.

Command is below:
/opt/SUNWstkcam/bin/sscs modify -a MyStorage -p disk_pool -b enable

I afraid that lost any data on the storage box after execute above command.

Please tell me what happening when I execute " /opt/SUNWstkcam/bin/sscs modify -a MyStorage -p disk_pool -b enable" command on the storage box?

BR,
Buyantugs

Last edited by DukeNuke2; 10-19-2011 at 07:51 AM..
 

10 More Discussions You Might Find Interesting

1. Solaris

Sun Sparc T2000 + StorageTek 2540 - Help, I'm lost

I have a Sun Sparc T2000 (Solaris 10 05-08) and have installed a PCI-X 4GB Single Port HBA card in it. I have one StorageTek 2540 array that I would like to connect to the T2000. For the moment it would be a single path connection, but I've ordered a 2nd HBA, so eventually it would be... (4 Replies)
Discussion started by: soliberus
4 Replies

2. Solaris

One StorageTek 6140 vs Two (2) 2540 's?

We're moving our production 3510FC to development, so we need to replace the production 3510FC. The 6140 is nice, but pricey. Here's the question: Would two 2540's (RAID 10) be 'faster' than one 3510? (RAID 10) and faster than one 6140 (RAID 10)? One StoregeTek 6140 (16x72GB 15k rpm fc-al... (12 Replies)
Discussion started by: buddhavelvet
12 Replies

3. Filesystems, Disks and Memory

Configure large volume on Sun StorageTek 2540 array

Hi, We have 12x1TB SATA disks in our array and I need to create 10TB volume. I defined new storage profile on array and when I tried to add volume, I faced with ~2TB limit for new volumes. I didn't find how to set another limit on my storage profile. Is there is a way to configure one large... (3 Replies)
Discussion started by: Sapfeer
3 Replies

4. Solaris

Sun StorageTek 2540 - shutdown matrix

Hi, I have a simple question on how to correctly disable the matrix? Looking for the Common Array Manager and I do not see this option... Thank for help (3 Replies)
Discussion started by: bieszczaders
3 Replies

5. Solaris

Storagetek 2540

Hi peeps, Was wondering if anyone can help me, got a couple of storagetek 2540's that I need to configure. Trouble is I think they were brought as second user as all that came with them was cables. Does anyone know how to configure them (i.e. create raid sets and map to Luns and present... (1 Reply)
Discussion started by: callmebob
1 Replies

6. Hardware

Storagetek 2540

Hello all ! I am a beginner about system and networking , and after some research on internet , i didn't find any relevant information , so i post here , if someone have an experience with this kind of material or if some documentation about how to connect my storage device on my server. I... (2 Replies)
Discussion started by: acorradi
2 Replies

7. Solaris

SUN 6540 Array with failed controller battery

Can someone point me to a procedure detailing the replacement of a failed battery in a SUN 6540 controller. Or describe the procedure. Thanks (1 Reply)
Discussion started by: USFE
1 Replies

8. Hardware

Storagetek 2540

Hi Guys and Gals, Wionder if you could help me, got a problem with a controller on a storagetek 2540, dead when fully powered up but if you reboot, it is ok for a couple of seconds (and you can ping it). Then once the array is fully up, it goes faulty and is un-pingable. Had anyone... (4 Replies)
Discussion started by: callmebob
4 Replies

9. Solaris

StorageTek 2540 SAN array

Bought a Sun StorageTek 2540 SAN array a few years ago from a company that was going out of business. When we first set it up, we were able to get all the software (Common Array Manager) and firmware directly from Sun. We just upgraded the drives, but the array is too large for the firmware. Now... (6 Replies)
Discussion started by: edison303
6 Replies

10. Solaris

Server M4000 server lost connectivity to storagetek 2540

Hi Guys, I have situation here ... server M4000 server lost connectivity to storagetek 2540 , storagetek 2540 unable to be ping.From DAS URL the storage is undetected. Any idea why this is happening. Please share. Thank you. Raj (1 Reply)
Discussion started by: muralirajah
1 Replies
BESTUPS(8)							    NUT Manual								BESTUPS(8)

NAME
bestups - Driver for Best Power / SOLA (Phoenixtec protocol) UPS equipment NOTE
This man page only documents the hardware-specific features of the bestups driver. For information about the core driver, see nutupsdrv(8). SUPPORTED HARDWARE
bestups was designed to monitor Best Power UPS hardware like the Fortress, Fortress Telecom, Axxium Rackmount and Patriot Pro. It also recognizes and supports SOLA units such as the 325, 520 and 620. In addition, the Best 610 is supported using the 'ID' option. Other UPS hardware using the Phoenixtec protocol should also work, but they will generate a warning since their battery information is not known. This driver does not support some older Best/SOLA units. EXTRA ARGUMENTS
This driver supports the following optional settings in the ups.conf(5): nombattvolt=num Override the battery float voltage which is normally determined by asking the hardware. This is useful if your UPS constantly reports battery.charge values just below 100% even when it's completely charged. If you have this problem, set this to whatever battery.voltage reports when the UPS is known to be completely charged with a good battery. The author's Best Fortress 750 uses nombattvolt=27.4. battvoltmult=num Multiply the reported battery voltage by this number. Some devices report only a fraction of the total battery voltage. For example, the SOLA 610 700VA UPS (with a 24V battery) reports the single cell voltage (about 2.27V when fully charged). In this particular case you can set battvoltmult = 12 in ups.conf(8) to fix this. ID=string Set the Identification response string. This should only be used with hardware that supports the Phoenixtec protocol status inquiry commands, but not the "ID" command, such as the Best/SOLA 610. Format of the ID string is: AAA,BBBB,CCC,DDD,EE.E,FF.F AAA is the three-character identification for the UPS model. BBBB is the output power in VA (volt amperes). B is an integer number ranging from 0 to 9. CCC is the Nominal Input Voltage. C is an integer number ranging from 0 to 9. The unit is Volts AC. DDD is the Nominal Output Voltage. D is an integer number ranging from 0 to 9. The unit is Volts AC. EE.E is the Battery Voltage that will cause the UPS to shut itself off. E is an integer number ranging from 0 to 9. Then unit is Volts DC and a decimal point is present. FF.F or FFF.F is the Battery Voltage at full charge. F is an integer number ranging from 0 to 9. Then unit is Volts DC. Typically, for 700VA, 1KVA and 1.5KVA units, the format is FF.F. For 2KVA and 3KVA units, the format is FFF.F. Example: a Best 610 1.5KVA unit would use the string "610,1500,120,120,10.0,48.0". BUGS
The battery charge percentage value (in battery.charge) is derived from the voltage data that the UPS returns, since the UPS doesn't return that value directly. On some hardware, the charge will remain at 100% for a long time and then drops quickly shortly before the battery runs out. You can confirm from the battery.voltage readings that this is a problem with the UPS and not this driver. Similarly, the float from the charger in some models forces the battery charge percentage back up to 100% immedately after the UPS goes back on-line, so you can't tell when it is really recharged. Finally, some models give one value for the battery's nominal voltage and yet actually have a nominal voltage slightly below that. This leads to things such as the perpetual 98.7% charge on the author's Fortress 750, even when it's been charging for weeks. You can use nombattvolt= in ups.conf(8) to fix this. AUTHOR
Russell Kroll, Jason White SEE ALSO
The core driver: nutupsdrv(8) Internet resources: The NUT (Network UPS Tools) home page: http://www.networkupstools.org/ Network UPS Tools 05/21/2012 BESTUPS(8)
All times are GMT -4. The time now is 06:03 AM.
Unix & Linux Forums Content Copyright 1993-2022. All Rights Reserved.
Privacy Policy