Sponsored Content
Full Discussion: AIX mirroring repair
Operating Systems AIX AIX mirroring repair Post 302563186 by DaySky on Monday 10th of October 2011 10:00:12 AM
Old 10-10-2011
Ok, funksen, merci beaucoup.
 

7 More Discussions You Might Find Interesting

1. UNIX for Advanced & Expert Users

fsck command - what does it check/repair??

While rebooting one of the UNIX systems here at work, the boot-up process halted and a message appeared telling me that I had to run the fsck command. The command to the best of my knowledge went something like : fsck -F ufs /dev/rdsk/c0t0d0s0 Can someone give me a full list of this command... (4 Replies)
Discussion started by: Kanu77
4 Replies

2. Shell Programming and Scripting

need help with oracle repair script

I have a problem. I am attempting to create a repair script for oracle that will read in a print file and perform a repair on an oracle database using the data in the print file. My restrictions are 1) each in list (items with-in parens) must be no more the 250 lines and the last item in the... (1 Reply)
Discussion started by: beilstwh
1 Replies

3. Windows & DOS: Issues & Discussions

Windows XP recovery/repair mode

hello again all, assume I can not log in to the windows installation, (maybe) because of a system file corruption or failure.. however, I do log in to the system using the windows CD with R (repair) mode, that is the command line prompt. Is there a way in that command prompt to copy the files... (10 Replies)
Discussion started by: milhan
10 Replies

4. UNIX for Dummies Questions & Answers

How to repair DNS

I am using Mac OS X and my server keeps crashing every several hours or so. I have checked the log file at /var/log/system.log and the entries closest to the crash read Mar 15 22:27:23 server servermgrd: servermgr_dns: no name available via DNS for 192.168.84.21 Mar 15 22:27:23 server... (4 Replies)
Discussion started by: timgolding
4 Replies

5. AIX

AIX unmirroring while mirroring in background

Hi, by mistake I ran unmirror while mirroring was running in the back ground. anyhow the unmirror operation failed with the following 0516-076 lreducelv: Cannot remove last good copy of stale partition. Resynchronize the partitions with syncvg and try again. 0516-922 rmlvcopy:... (0 Replies)
Discussion started by: ithinksgreen
0 Replies

6. Boot Loaders

Where to get windows 7 iso file of repair?

I need to make a bootable usb of windows 7 repair disc iso file so that I can use it in case my system doesn't boot up. On net I am getting complete windows 7 OS iso but I need only the repair disc for making bootable iso. I am not sure whether I used right word by using the word disc here... (3 Replies)
Discussion started by: ravisingh
3 Replies

7. Windows & DOS: Issues & Discussions

Repair windows 8.0 ntfs partition

I have a 1TB HD, suspect it had bad sectors and blocks... it was pre-installed with windows 8.0.. I was able to boot up ubuntu and looked at the partitions and run a badblocks comand to verify secotors, after getting a serious of Input and Output errors mounting the partition and doing any... (2 Replies)
Discussion started by: ppchu99
2 Replies
CCDCONFIG(8)						    BSD System Manager's Manual 					      CCDCONFIG(8)

NAME
ccdconfig -- configuration utility for the concatenated disk driver SYNOPSIS
ccdconfig [-cv] ccd ileave [flags] dev ... ccdconfig -C [-v] [-f config_file] ccdconfig -u [-v] ccd ... ccdconfig -U [-v] [-f config_file] ccdconfig -g [ccd ...] DESCRIPTION
The ccdconfig utility is used to dynamically configure and unconfigure concatenated disk devices, or ccds. For more information about the ccd, see ccd(4). The options are as follows: -c Configure a ccd. This is the default behavior of ccdconfig. -C Configure all ccd devices listed in the ccd configuration file. -f config_file When configuring or unconfiguring all devices, read the file config_file instead of the default /etc/ccd.conf. -g Dump the current ccd configuration in a format suitable for use as the ccd configuration file. If no arguments are specified, every configured ccd is dumped. Otherwise, the configuration of each listed ccd is dumped. -u Unconfigure a ccd. -U Unconfigure all ccd devices listed the ccd configuration file. -v Cause ccdconfig to be verbose. A ccd is described on the command line and in the ccd configuration file by the name of the ccd, the interleave factor, the ccd configuration flags, and a list of one or more devices. The flags may be represented as a decimal number, a hexadecimal number, a comma-separated list of strings, or the word ``none''. The flags are as follows: CCDF_UNIFORM 0x02 Use uniform interleave CCDF_MIRROR 0x04 Support mirroring CCDF_NO_OFFSET 0x08 Do not use an offset CCDF_LINUX 0x0A Linux md(4) compatibility The format in the configuration file appears exactly as if it were entered on the command line. Note that on the command line and in the configuration file, the flags argument is optional. # # /etc/ccd.conf # Configuration file for concatenated disk devices # # ccd ileave flags component devices ccd0 16 none /dev/da2s1 /dev/da3s1 The component devices need to name partitions of type FS_BSDFFS (or ``4.2BSD'' as shown by disklabel(8)). If you want to use the Linux md(4) compatibility mode, please be sure to read the notes in ccd(4). FILES
/etc/ccd.conf default ccd configuration file EXAMPLES
A number of ccdconfig examples are shown below. The arguments passed to ccdconfig are exactly the same as you might place in the /etc/ccd.conf configuration file. The first example creates a 4-disk stripe out of four scsi disk partitions. The stripe uses a 64 sector interleave. The second example is an example of a complex stripe/mirror combination. It reads as a two disk stripe of da4 and da5 which is mirrored to a two disk stripe of da6 and da7. The last example is a simple mirror. The 2nd slice of /dev/da8 is mirrored with the 3rd slice of /dev/da9 and assigned to ccd0. # ccdconfig ccd0 64 none /dev/da0s1 /dev/da1s1 /dev/da2s1 /dev/da3s1 # ccdconfig ccd0 128 CCDF_MIRROR /dev/da4 /dev/da5 /dev/da6 /dev/da7 # ccdconfig ccd0 128 CCDF_MIRROR /dev/da8s2 /dev/da9s3 The following are matching commands in Linux and FreeBSD to create a RAID-0 in Linux and read it from FreeBSD. # Create a RAID-0 on Linux: mdadm --create --chunk=32 --level=0 --raid-devices=2 /dev/md0 /dev/hda1 /dev/hdb1 # Make the RAID-0 just created available on FreeBSD: ccdconfig -c /dev/ccd0 32 linux /dev/ada0s1 /dev/ada0s2 When you create a new ccd disk you generally want to fdisk(8) and disklabel(8) it before doing anything else. Once you create the initial label you can edit it, adding additional partitions. The label itself takes up the first 16 sectors of the ccd disk. If all you are doing is creating file systems with newfs, you do not have to worry about this as newfs will skip the label area. However, if you intend to dd(1) to or from a ccd partition it is usually a good idea to construct the partition such that it does not overlap the label area. For example, if you have A ccd disk with 10000 sectors you might create a 'd' partition with offset 16 and size 9984. # disklabel ccd0 > /tmp/disklabel.ccd0 # disklabel -Rr ccd0 /tmp/disklabel.ccd0 # disklabel -e ccd0 The disklabeling of a ccd disk is usually a one-time affair. If you reboot the machine and reconfigure the ccd disk, the disklabel you had created before will still be there and not require reinitialization. Beware that changing any ccd parameters: interleave, flags, or the device list making up the ccd disk, will usually destroy any prior data on that ccd disk. If this occurs it is usually a good idea to reini- tialize the label before [re]constructing your ccd disk. RECOVERY
An error on a ccd disk is usually unrecoverable unless you are using the mirroring option. But mirroring has its own perils: It assumes that both copies of the data at any given sector are the same. This holds true until a write error occurs or until you replace either side of the mirror. This is a poor-man's mirroring implementation. It works well enough that if you begin to get disk errors you should be able to backup the ccd disk, replace the broken hardware, and then regenerate the ccd disk. If you need more than this you should look into external hardware RAID SCSI boxes, RAID controllers (see GENERIC), or software RAID systems such as geom(8) and gvinum(8). SEE ALSO
dd(1), ccd(4), disklabel(8), fdisk(8), gvinum(8), rc(8) HISTORY
The ccdconfig utility first appeared in NetBSD 1.0A. BUGS
The initial disklabel returned by ccd(4) specifies only 3 partitions. One needs to change the number of partitions to 8 using ``disklabel -e'' to get the usual BSD expectations. BSD
October 1, 2013 BSD
All times are GMT -4. The time now is 09:23 AM.
Unix & Linux Forums Content Copyright 1993-2022. All Rights Reserved.
Privacy Policy