Getting error while shutting down
Hi,
I am getting the error "/etc/rc.shutdown failed. Shutdown aborting" while shutting down the os.
Please suggest.
10 More Discussions You Might Find Interesting
1. UNIX for Dummies Questions & Answers
The method I use to shut down my box is as follows :
shutdown +3 -h
logout
the box indicates shutdown complete, so I switch off the power. When I reboot next time I get a Warning message in the bootup screen stating the that it was not shutdown correctly. being a newbie I'm kind of... (1 Reply)
Discussion started by: ferret
1 Replies
2. Solaris
What can I do to ensure that oracle database is shut down when the server reboots. (1 Reply)
Discussion started by: krishan
1 Replies
3. UNIX for Advanced & Expert Users
Hi
I have a mix of solaris 8,9 & 10. I need to have our 6 Solaris servers shutdown buy a script that will be executed by APC network Shutdown software
Im really not sure how I would write a script to shut them down and the following processes?
the processes are
portmapper
seq
seq_api... (1 Reply)
Discussion started by: tonysequoia
1 Replies
4. UNIX for Dummies Questions & Answers
Hi
Is there anyway i can find out from which terminal a shutdown command has been run from ? :( (3 Replies)
Discussion started by: ktech
3 Replies
5. Ubuntu
i really dont know any other way to put it besides that Ubuntu 8.04, that i just installed on my computer hangs when it shuts down. the bar depletes the orange like it should, but it never actually shuts down.
anyone know whats going on? (3 Replies)
Discussion started by: Texasone
3 Replies
6. Solaris
on solaris 8 i edited file rc0 in /sbin at last line
ex.
/sbin/sync; /sbin/sync; /sbin/sync
# Unmount file systems. /usr, /var, /var/adm, /var/run are not unmounted by
# umountall because they are mounted by rcS (for single user mode) rather than
# mountall. If this is changed,... (1 Reply)
Discussion started by: infjustice
1 Replies
7. Shell Programming and Scripting
While tomcat shutting down getting the below error.
Error occurred during initialization of VM
Could not reserve enough space for code cache
CATALINA_OPTS="-verbose:gc -Xloggc:gc.log -XX:+PrintGCDetails -XX:MaxPermSize=24M -Xms256M -Xmx512M -Djava.awt.headless=true -XX:-UseCompressedOops... (2 Replies)
Discussion started by: tuxslonik
2 Replies
8. Fedora
Hi All, I am pretty new to unix type languages. At work we have a server room with about 50 windows computers in one system and 50 in a unix system. We sometimes have power outages and I don't like the power slam. I wrote a windows batch file using sysinternals help to shutdown the windows... (4 Replies)
Discussion started by: Jeff Rollins
4 Replies
9. Solaris
I just installed this 11.2 ver and when I tell it to shutdown it takes for ever then just hangs with this just a little bit of that red line left to go, then it just sits there like forever until I get tired of looking at it then force a shutdown by holding my power button down until my laptop... (8 Replies)
Discussion started by: userx-bw
8 Replies
10. UNIX for Beginners Questions & Answers
Hi there,
I had issue with one of MY FC cards on T4-2 servers so system team replace it and start the machine but when launch FORMAT command so I don't see my shared disks coming from storage controller. i have checked at the Fabric switch so WWN numbers are visible and zones are ok and after... (1 Reply)
Discussion started by: janakors
1 Replies
LEARN ABOUT OPENDARWIN
clone
CLONE(8) NUT Manual CLONE(8)
NAME
clone - UPS driver clone
NOTE
This man page only documents the specific features of the clone driver. For information about the core driver, see nutupsdrv(8).
DESCRIPTION
This driver, which sits on top of another driver socket, allows users to group clients to a particular outlet of a device and deal with
this output as if it was a normal UPS.
EXTRA ARGUMENTS
This driver supports the following settings:
load.off=command
Recommended. Set the command on the "real" UPS driver that will be used to switch off the outlet. You need both load.off and load.on in
order to power cycle the outlet. Otherwise, shutting down the clients powered by an outlet is a one way street (see IMPORTANT).
load.on=command
Recommended. Set the command on the "real" UPS driver that will be used to switch on the outlet. You need both load.off and load.on in
order to power cycle the outlet. Otherwise, shutting down the clients powered by an outlet is a one way street (see IMPORTANT).
load.status=value
Recommended. Set the variable on the "real" UPS driver that will be used to indicate the outlet status (i.e. on/off). If not specified,
the clone driver will attempt to keep track of the outlet status, but this is less reliable.
offdelay=num
Set the timer (in seconds) before the outlet is turned off after the shutdown condition (OB LB) for this outlet is met or a command to
shutdown was issued. Defaults to 120 seconds.
ondelay=num
Set the timer (in seconds) for the outlet to switch on in case the power returns after the oulet has been switched off. Defaults to 30
seconds.
mincharge=value
Set the remaining battery level when the clone UPS switches to LB (percent).
minruntime=value
Set the remaining battery runtime when the clone UPS switches to LB (seconds).
IMPLEMENTATION
The port specification in the ups.conf(5) reference the driver socket that the "real" UPS driver is using. For example:
[realups]
driver = usbhid-ups
port = auto
[clone-outlet-1]
driver = clone
port = usbhid-ups-realups
load.on = outlet.1.load.on
load.off = outlet.1.load.off
load.status = outlet.1.status
[...]
IMPORTANT
Unlike a real UPS, you should not configure a upsmon master for this driver. When a upsmon master sees the OB LB flags and tells the upsd
server it is OK to initiate the shutdown sequence, the server will latch the FSD status and it will not be possible to restart the systems
connected without restarting the upsd server.
This will be a problem if the power returns after the clone UPS initiated the shutdown sequence on it's outlet, but returns before the real
UPS begins shutting down. The solution is in the clone driver, that will insert the FSD flag if needed without the help of a upsmon master.
CAVEATS
The clone UPS will follow the status on the real UPS driver. You can only make the clone UPS shutdown earlier than the real UPS driver, not
later. If the real UPS driver initiates a shutdown, the clone UPS driver will immediately follow.
Be aware that the commands to shutdown/restart an outlet on the real UPS drivers are not affected, so if you tell the real UPS driver to
shutdown the outlet of the clone UPS driver, your clients will lose power without warning.
AUTHOR
Arjen de Korte <adkorte-guest@alioth.debian.org>
SEE ALSO
upscmd(1), upsrw(1), ups.conf(5), nutupsdrv(8)
Internet Resources:
The NUT (Network UPS Tools) home page: http://www.networkupstools.org/
Network UPS Tools 05/21/2012 CLONE(8)