Does anyone know how to force these rogue logical volumes to mirror to there respective disks?
DISK:Logical Volumes
03:cw_p05,cw_p01_01,cw_p01_02,lv00
09:cw_p05,cw_p01_01,cw_p01_02
04:cw_p01_phyldbs,cw_p01_03,cw_op01_01,cw_od01
10:cw_p01_phyldbs,cw_p01_03,cw_op01_01 (1 Reply)
I hope I am posting in the correct forum.
I have a server - which I am installing solaris 9 on.
The server currently has 2 disks. I wish to run solaris 9 on one, and use the other as a mirror for the first one. ie. If the first one should ever fail, then I can swap to the mirror and just... (18 Replies)
I've looked a little but haven't found a solid answer, assuming there is one.
What's better, hardware mirroring or ZFS mirroring? Common practice for us was to use the raid controllers on the Sun x86 servers. Now we've been using ZFS mirroring since U6. Any performance difference? Any other... (3 Replies)
Hi ,
I am new to SVM .when i try to learn RAID 1 , first they are creating two RAID 0 strips through
metainit d51 1 1 c0t0d0s2
metainit d52 1 1 c1t0d0s2
In the next step
metainit d50 -m d51
d50: Mirror is setup
next step is
metaattach d50 d52
d50 : submirror d52 is... (7 Replies)
Hi guys,
We had created a pool as follows:
zpool create filing_pool raidz c1t2d0 c1t3d0 ........
Due to some requirement, we need to destroy the pool and re-create another one. We wish to know now which disks have been included in the filing_pool, how do we list the disks used to create... (2 Replies)
i have this pool1 on my sun4u sparc machine
bash-3.00# zpool get all pool1
NAME PROPERTY VALUE SOURCE
pool1 size 292G -
pool1 used 76.5K -
pool1 available 292G -
pool1 capacity 0% -... (1 Reply)
I have to do patching in single user mode in solaris 10 zfs root pool. Before that I have to detach the root mirror pool so that if patching fails then I can boot from detached root mirror pool. Please let me know how can I detach root pool
bash-3.2# zpool status
pool: rpool
state: ONLINE... (5 Replies)
Discussion started by: hb00
5 Replies
LEARN ABOUT SUSE
irsend
IRSEND(1) FSF IRSEND(1)NAME
irsend - basic LIRC program to send infra-red commands
SYNOPSIS
irsend [options] DIRECTIVE REMOTE CODE [CODE...]
DESCRIPTION
Asks the lircd daemon to send one or more CIR (Consumer Infra-Red) commands. This is intended for remote control of electronic devices such
as TV boxes, HiFi sets, etc.
DIRECTIVE can be:
SEND_ONCE - send CODE [CODE ...] once
SEND_START - start repeating CODE
SEND_STOP - stop repeating CODE
LIST - list configured remote items
SET_TRANSMITTERS - set transmitters NUM [NUM ...]
SIMULATE - simulate IR event
REMOTE is the name of a remote, as described in the lircd configuration file.
CODE is the name of a remote control key of REMOTE, as it appears in the lircd configuration file.
NUM is the transmitter number of the hardware device.
For the LIST DIRECTIVE, REMOTE and/or CODE can be empty:
LIST "" "" - list all configured remote names
LIST REMOTE "" - list all codes of REMOTE
LIST REMOTE CODE - list only CODE of REMOTE
The SIMULATE command only works if it has been explicitly enabled in lircd.
-h --help
display usage summary
-v --version
display version
-d --device
use given lircd socket [/var/run/lirc/lircd]
-a --address=host[:port]
connect to lircd at this address
-# --count=n
send command n times
EXAMPLES
irsend LIST DenonTuner ""
irsend SEND_ONCE DenonTuner PROG-SCAN
irsend SEND_ONCE OnkyoAmpli VOL-UP VOL-UP VOL-UP VOL-UP
irsend SEND_START OnkyoAmpli VOL-DOWN ; sleep 3
irsend SEND_STOP OnkyoAmpli VOL-DOWN
irsend SET_TRANSMITTERS 1
irsend SET_TRANSMITTERS 1 3 4
irsend SIMULATE "0000000000000476 00 OK TECHNISAT_ST3004S"
FILES
/etc/lirc/lircd.conf
Default lircd configuration file. It should contain all the remotes, their infra-red codes and the corresponding timing and wave-
form details.
DIAGNOSTICS
If lircd is not running (or /var/run/lirc/lircd lacks write permissions) irsend aborts with the following diagnostics:
"irsend: could not connect to socket"
"irsend: Connection refused" (or "Permission denied").
SEE ALSO
The documentation for lirc is maintained as html pages. They are located under html/ in the documentation directory.
lircd(8), mode2(1), smode2(1), xmode2(1), irrecord(1), irw(1), http://www.lirc.org.
irsend 0.8.7pre1 May 2010 IRSEND(1)