Sponsored Content
Operating Systems AIX AIX Sanboot from EMC Symmetrix with NPIV Post 302547315 by pwright84 on Monday 15th of August 2011 07:00:20 AM
Old 08-15-2011
I have done Power 7 with AIX 6.1 SAN booting using EMC and Powerpath on numerous occasions and works fine. What issue you having?
 

10 More Discussions You Might Find Interesting

1. UNIX for Advanced & Expert Users

Good sites to learn EMC symmetrix

i need to learn this very quick. i'm not trying delve deep into it. just enough to do basic things. does anyone know of any good sites to visit?? (1 Reply)
Discussion started by: TRUEST
1 Replies

2. HP-UX

is anybody using EMC symmetrix?

Hello, I'm looking for reference sites using HP-UX and EMC symmetrix disk. Then, May I ask you questions? (6 Replies)
Discussion started by: cooldugong
6 Replies

3. UNIX for Advanced & Expert Users

AIX MPIO and EMC

We are looking at running MPIO for it's redundancy and load balancing benefits. Does anyone know what pieces of software or modules are needed on the VIO server to get load balancing to work. Remember we are using EMC's DMX3500 storage system. We no longer want to use Powerpath. :rolleyes: ... (2 Replies)
Discussion started by: vxg0wa3
2 Replies

4. HP-UX

Adding a new set of hardisk in EMC Symmetrix

Hello everyone! Could anybody help me how to configure a set of disk? From our existing EMC storage, we still have spaces for a new set of disk. I know how to replace a deffective disk but never had experience in setting/replacing a new pair of disk (M1 and M2). My objective here is to increase... (1 Reply)
Discussion started by: Tris
1 Replies

5. AIX

Configurin EMC SAN disks on AIX

This may sound like an absolute rookie question, and it is. I have been working on Migrating our HP and Solaris servers to the new EMC SAN and know the routines backwards. Now we've suddenly got a new IBM server and I don't even know how to check if it is connected to the switch. Can someone... (1 Reply)
Discussion started by: ronellevan
1 Replies

6. AIX

Need EMC Symmetrix driver for AIX 5.3

Hi all, I hope I'm putting my first post at this site into the right forum. I need help finding the EMC disk driver for AIX version 5.3. I have some new EMC disk presented to a backup server of mine, and right now the EMC hdisks show up looking like this in an lsdev: hdisk495 Available... (2 Replies)
Discussion started by: C.J.Hund
2 Replies

7. AIX

Anyone using NPIV?

Is anyone here using NPIV with AIX? If you are, what type of switch are you connected to? Also, please share some impressions of NPIV over traditional port-to-port LUN assignments. We are looking to move to NPIV and need some convincing argume... I mean information. (2 Replies)
Discussion started by: kah00na
2 Replies

8. AIX

AIX san boot from EMC2 & NPIV

Hi all , we're implementing a new NPIV infrastructure with AIX san boot on EMC2 VMAX 5876 , for economic reason , they don't wont to install Powerpath multipath sw , but only ODM drivers from EMC2 , this behavior is supported and can work?! in the past we implemented NPIV on DS8000 family... (2 Replies)
Discussion started by: BabylonRocker76
2 Replies

9. AIX

AIX Migration issue with EMC ODM sets

Hi Experts , I want to start migrating our AIX 6.1 to AIX 7.1 . I am planning to use alt_disk_migration . Chris gibson has awesome documentation in the internet. However I am running into an issue with EMC odm filesets . So my current OS is AIX 6.1. and I have this : lslpp -l | grep EMC ... (7 Replies)
Discussion started by: JME2015
7 Replies

10. AIX

AIX help -reconnect EMC lun

we have an old AIX system with important data on an EMC LUN. the AIX server crashed and we had to rebuild it with the old AIX os 5.8. how do we reconnect the EMC LUN without losing the data? (15 Replies)
Discussion started by: jhudson12
15 Replies
st_san_safe(5)							     OBSOLETED							    st_san_safe(5)

NAME
st_san_safe - determine whether access to tape device special files without the no-rewind-on-close option is allowed (OBSOLETED) VALUES
Failsafe Default Allowed values Recommended values or DESCRIPTION
Note: this tunable is obsoleted and has been renamed to beginning with release HP-UX 11i v3. This tunable notifies the tape driver whether it should allow access to device special files without the no-rewind-on-close option. When this tunable is on the tape driver will fail any open on a tape device special file without the no-rewind-on-close option (that is, or with a status of The tunable allows the safe sharing of tape devices in SAN tape backup solution configurations. The disabling of device special files without no-rewind-on-close in a SAN tape backup solution configuration prevents the accidental sending of a rewind command on close from HP-UX systems via standard tape commands like which would corrupt a backup in process. Who Is Expected to Change This Tunable? Anyone. Restrictions on Changing Changes to this tunable take effect immediately. When Should the Tunable Be Turned On? This tunable should be turned on if the system is going to be used in a SAN tape backup solution configuration. What Are the Side Effects of Turning the Tunable On? The tape driver will fail any open to a tape device special file that does not have the no-rewind-on-close option with a status of This behavior prevents the usage of any tape device special file without the no-rewind-on-close option. When Should the Tunable Be Turned Off? This tunable should be turned off if the system is not part of a SAN tape backup solution configuration or the system utilizes will not function unless it has access to device special files without the no-rewind-on-close option. What Are the Side Effects of Turning the Tunable Off? A rewind may be issued from this system accidentally on close possibly corrupting a backup being issued from another system on the SAN. What Other Tunables Should Be Changed at the Same Time? None. WARNINGS
All HP-UX kernel tunable parameters are release specific. This parameter may be removed or have its meaning changed in future releases of HP-UX. Installation of optional kernel software, from HP or other vendors, may cause changes to tunable parameter values. After installation, some tunable parameters may no longer be at the default or recommended values. For information about the effects of installation on tun- able values, consult the documentation for the kernel software being installed. For information about optional kernel software that was factory installed on your system, see at AUTHOR
was developed by Hewlett-Packard. SEE ALSO
norewind_close_disabled(5), scsi_tape(7), scsimgr_estape(7). Tunable Kernel Parameters st_san_safe(5)
All times are GMT -4. The time now is 06:45 PM.
Unix & Linux Forums Content Copyright 1993-2022. All Rights Reserved.
Privacy Policy