Sponsored Content
Operating Systems AIX AIX Sanboot from EMC Symmetrix with NPIV Post 302547315 by pwright84 on Monday 15th of August 2011 07:00:20 AM
Old 08-15-2011
I have done Power 7 with AIX 6.1 SAN booting using EMC and Powerpath on numerous occasions and works fine. What issue you having?
 

10 More Discussions You Might Find Interesting

1. UNIX for Advanced & Expert Users

Good sites to learn EMC symmetrix

i need to learn this very quick. i'm not trying delve deep into it. just enough to do basic things. does anyone know of any good sites to visit?? (1 Reply)
Discussion started by: TRUEST
1 Replies

2. HP-UX

is anybody using EMC symmetrix?

Hello, I'm looking for reference sites using HP-UX and EMC symmetrix disk. Then, May I ask you questions? (6 Replies)
Discussion started by: cooldugong
6 Replies

3. UNIX for Advanced & Expert Users

AIX MPIO and EMC

We are looking at running MPIO for it's redundancy and load balancing benefits. Does anyone know what pieces of software or modules are needed on the VIO server to get load balancing to work. Remember we are using EMC's DMX3500 storage system. We no longer want to use Powerpath. :rolleyes: ... (2 Replies)
Discussion started by: vxg0wa3
2 Replies

4. HP-UX

Adding a new set of hardisk in EMC Symmetrix

Hello everyone! Could anybody help me how to configure a set of disk? From our existing EMC storage, we still have spaces for a new set of disk. I know how to replace a deffective disk but never had experience in setting/replacing a new pair of disk (M1 and M2). My objective here is to increase... (1 Reply)
Discussion started by: Tris
1 Replies

5. AIX

Configurin EMC SAN disks on AIX

This may sound like an absolute rookie question, and it is. I have been working on Migrating our HP and Solaris servers to the new EMC SAN and know the routines backwards. Now we've suddenly got a new IBM server and I don't even know how to check if it is connected to the switch. Can someone... (1 Reply)
Discussion started by: ronellevan
1 Replies

6. AIX

Need EMC Symmetrix driver for AIX 5.3

Hi all, I hope I'm putting my first post at this site into the right forum. I need help finding the EMC disk driver for AIX version 5.3. I have some new EMC disk presented to a backup server of mine, and right now the EMC hdisks show up looking like this in an lsdev: hdisk495 Available... (2 Replies)
Discussion started by: C.J.Hund
2 Replies

7. AIX

Anyone using NPIV?

Is anyone here using NPIV with AIX? If you are, what type of switch are you connected to? Also, please share some impressions of NPIV over traditional port-to-port LUN assignments. We are looking to move to NPIV and need some convincing argume... I mean information. (2 Replies)
Discussion started by: kah00na
2 Replies

8. AIX

AIX san boot from EMC2 & NPIV

Hi all , we're implementing a new NPIV infrastructure with AIX san boot on EMC2 VMAX 5876 , for economic reason , they don't wont to install Powerpath multipath sw , but only ODM drivers from EMC2 , this behavior is supported and can work?! in the past we implemented NPIV on DS8000 family... (2 Replies)
Discussion started by: BabylonRocker76
2 Replies

9. AIX

AIX Migration issue with EMC ODM sets

Hi Experts , I want to start migrating our AIX 6.1 to AIX 7.1 . I am planning to use alt_disk_migration . Chris gibson has awesome documentation in the internet. However I am running into an issue with EMC odm filesets . So my current OS is AIX 6.1. and I have this : lslpp -l | grep EMC ... (7 Replies)
Discussion started by: JME2015
7 Replies

10. AIX

AIX help -reconnect EMC lun

we have an old AIX system with important data on an EMC LUN. the AIX server crashed and we had to rebuild it with the old AIX os 5.8. how do we reconnect the EMC LUN without losing the data? (15 Replies)
Discussion started by: jhudson12
15 Replies
pm_trans_check(9F)					   Kernel Functions for Drivers 					pm_trans_check(9F)

NAME
pm_trans_check - Device power cycle advisory check SYNOPSIS
#include <sys/sunddi.h> int pm_trans_check(struct pm_trans_data *datap, time_t *intervalp); INTERFACE LEVEL
Solaris DDI specific (Solaris DDI) PARAMETERS
datap Pointer to a pm_trans_data structure intervalp Pointer to time difference when next power cycle will be advised DESCRIPTION
The pm_trans_check() function checks if a power-cycle is currently advised based on data in the pm_trans_data structure. This function is provided to prevent damage to devices from excess power cycles; drivers for devices that are sensitive to the number of power cycles should call pm_trans_check() from their power(9E) function before powering-off a device. If pm_trans_check() indicates that the device should not be power cycled, the driver should not attempt to power cycle the device and should fail the call to power(9E) entry point. If pm_trans_check() returns that it is not advised to power cycle the device, it attempts to calculate when the next power cycle is advised, based on the supplied parameters. In such case, intervalp returns the time difference (in seconds) from the current time to when the next power cycle is advised. If the time for the next power cycle cannot be determined, intervalp indicates 0. To avoid excessive calls to the power(9E) entry point during a period when power cycling is not advised, the driver should mark the corre- sponding device component busy for the intervalp time period (if interval is not 0). Conveniently, the driver can utilize the fact that calls to pm_busy_component(9F) are stacked. If power cycling is not advised, the driver can call pm_busy_component(9F) and issue a time- out(9F) for the intervalp time. The timeout() handler can issue the corresponding pm_idle_component(9F) call. When the format field of pm_trans_data is set to DC_SCSI_FORMAT, the caller must provide valid data in svc_date[], lifemax, and ncycles. Currently, flag must be set to 0. struct pm_scsi_cycles { int lifemax; /* lifetime max power cycles */ int ncycles; /* number of cycles so far */ char svc_date[DC_SCSI_MFR_LEN]; /* service date YYYYWW */ int flag; /* reserved for future */ }; struct pm_trans_data { int format; /* data format */ union { struct pm_scsi_cycles scsi_cycles; } un; }; RETURN VALUES
1 Power cycle is advised 0 Power cycle is not advised -1 Error due to invalid argument. ATTRIBUTES
See attributes(5) for descriptions of the following attributes: +-----------------------------+-----------------------------+ | ATTRIBUTE TYPE | ATTRIBUTE VALUE | +-----------------------------+-----------------------------+ |Interface Stability |Committed | +-----------------------------+-----------------------------+ SEE ALSO
power.conf(4), attributes(5), power(9E) Writing Device Drivers Using Power Management SunOS 5.11 16 Oct 1999 pm_trans_check(9F)
All times are GMT -4. The time now is 06:19 AM.
Unix & Linux Forums Content Copyright 1993-2022. All Rights Reserved.
Privacy Policy