Sponsored Content
Full Discussion: sddpcm on vio
Operating Systems AIX sddpcm on vio Post 302545160 by mk8570 on Sunday 7th of August 2011 01:36:26 AM
Old 08-07-2011
I did check and the reserve is set to off.

Another question, I have 2 physical FC adapters allocated to each of the VIO Server.

So, when I map the adapters to the hosts using vfcmap , Should I be mapping both the fcp to the vfchosts0 ? if yes, how ?


Code:
 
vfcmap -vadpater vfchost0 -fcp fcs1 
 
$ lsmap -npiv -vadapter vfchost0
Name          Physloc                            ClntID ClntName       ClntOS
------------- ---------------------------------- ------ -------------- -------
vfchost0      U8233.E8B.06D091P-V1-C14                3
 
Status:NOT_LOGGED_IN
FC name:fcs1                    FC loc code:U5802.001.9K8H757-P1-C3-T2
Ports logged in:0
Flags:4<NOT_LOGGED>
VFC client name:                VFC client DRC:

 

10 More Discussions You Might Find Interesting

1. AIX

SDD SDDPCM MPIO lspath Jargon

Can anyone recommend me some reading material surrounding how AIX handles LUNs: - with and without MPIO installed - with and without SDD or SDDPCM installed Where does lspath sit in all of this (MPIO layer?). Can a system be built with just MPIO software? Is MPIO software even needed? I guess... (0 Replies)
Discussion started by: apra143
0 Replies

2. AIX

vio server and vio client

Hi, I want to know wheather partition size for installation of vio client can be specified on vio server example If I am installing vio server on blade with 2*300gb hard disk,after that I want to create 2 vio client (AIX Operating system) wheather I can specify hard disk size while... (1 Reply)
Discussion started by: manoj.solaris
1 Replies

3. AIX

AIX with SDD to VIOed SDDPCM?

Hi folks. We want to move a "physical" AIX box to a VIOed LPAR. The physical box is running SDD with disks from a DS8300. I want to be able to reattach those LUNs from the DS8300 to my VIO server which is running SDDPCM and then assigned them back to my AIX LPAR. Any thoughts about this? I... (1 Reply)
Discussion started by: Stephan
1 Replies

4. AIX

VIO Redundancy

Hi Guys, I'm working on building a new 595 machine.. I'm try to achieve high availability for the VIO clients using 2 VIO servers, The ethernet part is satisfied using SEA failover, Now how do I achieve redundancy for the disks, its the servers internal disk attached to the scsi cards... ... (2 Replies)
Discussion started by: kkeng808
2 Replies

5. AIX

Upgrading from native MPIO to SDDPCM AIX 6.1

We have AIX 6.1 system attached to SAN disks (DS4700 and DS8100) thru SVC. Initially when the system was I forgot to install sddpcm drivers. and wanted to know how can i go with the installation of the sddpcm drivers. My understandin going thru the manual ... (3 Replies)
Discussion started by: mk8570
3 Replies

6. AIX

Vio Build

I am planning carving out dual VIO servers on a P750 based and would like to know how to allocate internal disks to the VIOS. This has 4 internal disks and I would to assign 2 disks to each VIO. This is what I was thinking of assigning . Any advise? vio1 U5802.001.9K8H757-P1-C1 PCI-E x8... (17 Replies)
Discussion started by: mk8570
17 Replies

7. Red Hat

vio in linux

I am working in AIX. In a P series machine both aix and linux os can install.. specific command is there for aix to list out the vio servers details mapped in a frame(ie. lssrc "IBM.ManagementServer", like that..) is there any command is der to list out vio servers details in linux or how to find... (1 Reply)
Discussion started by: muralikrish
1 Replies

8. AIX

vio server ethernet to vio client ethernet(concepts confusing)

Hi In the vio server when I do # lsattr -El hdisk*, I get a PVID. The same PVID is also seen when I put the lspv command on the vio client partition. This way Im able to confirm the lun using the PVID. Similarly how does the vio client partition gets the virtual ethernet scsi client adapter... (1 Reply)
Discussion started by: newtoaixos
1 Replies

9. AIX

VIO Server

Hi, I am facing an issue in vio server. When I run bosboot -ad /dev/hdisk0 I am getting an error trustchk: Verification of attributes failed: /usr/sbin/bootinfo : accessauths regards, vjm Please use code tags next time for your code and data. (8 Replies)
Discussion started by: vjm
8 Replies

10. AIX

Need Help with SDD / SDDPCM / MPIO

This is getting very confusing for me, and appreciate if someone can help. Platform: Power VM ( Virtual I/O Server) ioslevel 2.1.3.10-FP23 # oslevel -s 6100-05-00-0000 Storage: IBM DS4300 Two HBAs - Dual Port Fibre Adapter Channels Each card has two ports , so a total of 4 ports going... (3 Replies)
Discussion started by: filosophizer
3 Replies
statd(1M)																 statd(1M)

NAME
statd, rpc.statd - network status monitor SYNOPSIS
DESCRIPTION
is an RPC server. It interacts with to provide the crash and recovery functions for the locking services on NFS (see lockd(1M)). keeps track of the clients with processes which hold locks on a server. When the server reboots after a crash, sends a message to the on each client indicating that the server has rebooted. The client processes then informs the on the client that the server has rebooted. The client then attempts to reclaim the lock(s) from the server. on the client host also informs the on the server(s) holding locks for the client when the client has rebooted. In this case, the on the server informs its that all locks held by the rebooting client should be released, allowing other processes to lock those files. Options recognizes the following options and command-line arguments: This is an obsolete option. All messages and errors are logged to WARNINGS
The crash of a server is only detected upon its recovery. FILES
lists hosts and network addresses to be contacted after a reboot lists hosts and network addresses that could not be contacted after last reboot includes a number which changes during a reboot AUTHOR
was developed by Sun Microsystems, Inc. SEE ALSO
lockd(1M), fcntl(2), lockf(2), signal(2), sm(4). statd(1M)
All times are GMT -4. The time now is 11:02 PM.
Unix & Linux Forums Content Copyright 1993-2022. All Rights Reserved.
Privacy Policy