07-27-2011
It's hard to say without having access to the hardware unfortunately. I don't suppose you have access to an oscilloscope or logic probe to check the tx pin with?
I wonder if it has anything to do with flow control.
10 More Discussions You Might Find Interesting
1. Programming
How can 'popen()' be used for reading and writing to opening pipe?
If i try 'popen("prog", "rw")'
and then put and get chars - it does
not work.
What is wrong? (1 Reply)
Discussion started by: szzz
1 Replies
2. Shell Programming and Scripting
I have tried to show the file name whose size is greater than 200 byte in current directory.
Please help me.
ls -l | tr -s " " " " | cut -f 5,9 -d " " >out.txt
#set -a x `cat out.txt`
i=0
`cat out.txt` | while
do
read x
echo $x
#re=200
j=0
if }" < "200" ]
then
echo $j
j=`expr $j... (2 Replies)
Discussion started by: rinku
2 Replies
3. Shell Programming and Scripting
I need to find all the files that have group Read or Write permission or files that have user write permission.
This is what I have so far:
find . -exec ls -l {} \; | awk '/-...rw..w./ {print $1 " " $3 " " $4 " " $9}'
It shows me all files where group read = true, group write = true... (5 Replies)
Discussion started by: shunter63
5 Replies
4. Programming
Hi all,
I have a problem with some read/write functions.
I have a .bin file which contains a lot of structures as follows:
struct alumno
{
char id;
char apellido1;
char apellido2;
char nombre;
float nota1p;
float nota2p;
float notamedia;
char photofilename;
};
What I have... (3 Replies)
Discussion started by: Attenea
3 Replies
5. IP Networking
Hi,
We have smb client running on two of the linux boxes and smb server on another linux system. During a backup operation which uses smb, read of a file was allowed while write to the same file was going on.Also simultaneous writes to the same file were allowed.Following are the settings in the... (1 Reply)
Discussion started by: swatidas11
1 Replies
6. IP Networking
hi
am newbie to unix and socket programing
I am trying to figuring out syntax for read and write
to send data from server to client and client can read it
I have to send two integers
write(newsockfd,buffer,"%d %d",x,y,0) writing from client where x and y are two integers..
... (7 Replies)
Discussion started by: karthik1238
7 Replies
7. Programming
HI
I need to implement a client/server TCP application. the customer is the client and the bartender is the server.
When the customer enter the Bar, client connects to the server
Server should reply the client immediately. Other wise if the server is busy, it should send an update message... (10 Replies)
Discussion started by: lixiao1212
10 Replies
8. Emergency UNIX and Linux Support
Hi,
I have been trying to capture console logs from the init script.
When the ramfs is mounted, i check if usb is connected , if conncted, i mount it and redirected the console logs like so:
cat & /dev/ttyS1 >> /mnt/logs.txt
I'm getting
/bin/sh : /dev/ttyS1 :permission denied
... (8 Replies)
Discussion started by: xerox
8 Replies
9. Shell Programming and Scripting
I have got a file in following format:
AAAAAAA
BBBBBBBB
CCCCCCC
DDDDDDD
I am trying to read this file and out put it in following format:
AAAAAAA,BBBBBBB,CCCCCCC,DDDDDD
Preferred method is shell or Perl.
Any help appreciated. (11 Replies)
Discussion started by: Araoki
11 Replies
10. Programming
Can someone help me to write this program in C in QNX?
Using the FIFO queues write a simple communication system consisting of programs write and read. The program write the parameters given strings enclosed in single quotes. These strings are written to the FIFO file. Reads the program read... (1 Reply)
Discussion started by: ebasse2
1 Replies
LEARN ABOUT OSF1
port_names
ports(7) Miscellaneous Information Manual ports(7)
NAME
ports, port_names - Device (tty and lp) names for serial and parallel ports
SYNOPSIS
Default Serial Ports:
/dev/tty00
/dev/tty01 (not present on a single-port system)
Parallel Port:
/dev/lp0
DESCRIPTION
AlphaStation and AlphaServer systems provide one or two 9-pin serial communication ports. These ports are usually labelled 1 (COMM1) and 2
(COMM2), but they may be identified by different icons. Using the appropriate serial cable and terminator, you can connect a serial
printer, external modem, or character-cell terminal to a serial port. Most AlphaStation and AlphaServer systems also provide one parallel
port, for use with a parallel printer.
When you add a device to your system, the installation documentation may instruct you to map the device pathname to the port. These
devices are located in the /dev directory.
For serial-line ports, the two default device pathnames are: This pathname always maps to 1, COMM1, the lowest port number, an icon for a
terminal console, or the only serial port (on a single-port system). This pathname always maps to 2, COMM2, the next numbered port, or (if
one serial port is labeled with an icon for a terminal console) the remaining serial port.
If your system hardware has been extended to include additional serial ports, the pathnames /dev/tty02, /dev/tty03, and so forth, may also
be available to you. However, most systems have only /dev/tty00 and /dev/tty01 as the device pathnames for serial ports.
The one parallel port on an AlphaStation or AlphaServer may be labeled with the word printer or a printer icon. On some systems, the paral-
lel port may not be labeled. The device pathname for the parallel port is /dev/lp0. Currently, Tru64 UNIX does not fully support parallel
printers, so fewer devices are connected to this port as compared to serial ports.
If you are connecting a terminal console to your system, it must be connected to the serial port mapped to /dev/tty00. For other serial
devices, it does not matter which of the serial ports you choose for the connection. For example, suppose you are setting up a system that
has two serial ports, labeled 1 and 2. You intend to use a serial-line terminal rather than a workstation monitor as the system console and
also want to connect a serial-line printer to the system. In this case, you must connect the terminal to the port labeled 1 (with the
device pathname /dev/tty00). Therefore, you must connect the printer to the remaining port labeled 2 (with the device pathname /dev/tty01).
If, for the same type of system, you intend to use a workstation monitor as the system console, it does not matter which serial port you
use for a serial-line printer or modem. In other words, you can connect the printer to either port 1 (with pathname /dev/tty00) or port 2
(with pathname /dev/tty01). When prompted to enter a /dev/tty** pathname by the lprsetup script or the Print configuration tool in the CDE
Application Manager, you would specify /dev/tty00 if you connected the printer to port 1 or /dev/tty01 if you connected the printer to port
2.
See the System Administration manual for more information on setting up consoles (including remote consoles) and printers. See the
modem(7) reference page for more information on setting up modems.
SEE ALSO
Commands: lprsetup(8)
Devices: ace(7), modem(7)
System Administration delim off
ports(7)