Code:
# prtdiag -v
System Configuration: Sun Microsystems sun4v T5440
Memory size: 32480 Megabytes
================================ Virtual CPUs ================================
CPU ID Frequency Implementation Status
------ --------- ---------------------- -------
0 1414 MHz SUNW,UltraSPARC-T2+ on-line
1 1414 MHz SUNW,UltraSPARC-T2+ on-line
2 1414 MHz SUNW,UltraSPARC-T2+ on-line
3 1414 MHz SUNW,UltraSPARC-T2+ on-line
4 1414 MHz SUNW,UltraSPARC-T2+ on-line
5 1414 MHz SUNW,UltraSPARC-T2+ on-line
6 1414 MHz SUNW,UltraSPARC-T2+ on-line
7 1414 MHz SUNW,UltraSPARC-T2+ on-line
8 1414 MHz SUNW,UltraSPARC-T2+ on-line
9 1414 MHz SUNW,UltraSPARC-T2+ on-line
10 1414 MHz SUNW,UltraSPARC-T2+ on-line
11 1414 MHz SUNW,UltraSPARC-T2+ on-line
12 1414 MHz SUNW,UltraSPARC-T2+ on-line
13 1414 MHz SUNW,UltraSPARC-T2+ on-line
14 1414 MHz SUNW,UltraSPARC-T2+ on-line
15 1414 MHz SUNW,UltraSPARC-T2+ on-line
16 1414 MHz SUNW,UltraSPARC-T2+ on-line
17 1414 MHz SUNW,UltraSPARC-T2+ on-line
18 1414 MHz SUNW,UltraSPARC-T2+ on-line
19 1414 MHz SUNW,UltraSPARC-T2+ on-line
20 1414 MHz SUNW,UltraSPARC-T2+ on-line
21 1414 MHz SUNW,UltraSPARC-T2+ on-line
22 1414 MHz SUNW,UltraSPARC-T2+ on-line
23 1414 MHz SUNW,UltraSPARC-T2+ on-line
24 1414 MHz SUNW,UltraSPARC-T2+ on-line
25 1414 MHz SUNW,UltraSPARC-T2+ on-line
26 1414 MHz SUNW,UltraSPARC-T2+ on-line
27 1414 MHz SUNW,UltraSPARC-T2+ on-line
28 1414 MHz SUNW,UltraSPARC-T2+ on-line
29 1414 MHz SUNW,UltraSPARC-T2+ on-line
30 1414 MHz SUNW,UltraSPARC-T2+ on-line
31 1414 MHz SUNW,UltraSPARC-T2+ on-line
32 1414 MHz SUNW,UltraSPARC-T2+ on-line
33 1414 MHz SUNW,UltraSPARC-T2+ on-line
34 1414 MHz SUNW,UltraSPARC-T2+ on-line
35 1414 MHz SUNW,UltraSPARC-T2+ on-line
36 1414 MHz SUNW,UltraSPARC-T2+ on-line
37 1414 MHz SUNW,UltraSPARC-T2+ on-line
38 1414 MHz SUNW,UltraSPARC-T2+ on-line
39 1414 MHz SUNW,UltraSPARC-T2+ on-line
40 1414 MHz SUNW,UltraSPARC-T2+ on-line
41 1414 MHz SUNW,UltraSPARC-T2+ on-line
42 1414 MHz SUNW,UltraSPARC-T2+ on-line
43 1414 MHz SUNW,UltraSPARC-T2+ on-line
44 1414 MHz SUNW,UltraSPARC-T2+ on-line
45 1414 MHz SUNW,UltraSPARC-T2+ on-line
46 1414 MHz SUNW,UltraSPARC-T2+ on-line
47 1414 MHz SUNW,UltraSPARC-T2+ on-line
48 1414 MHz SUNW,UltraSPARC-T2+ on-line
49 1414 MHz SUNW,UltraSPARC-T2+ on-line
50 1414 MHz SUNW,UltraSPARC-T2+ on-line
51 1414 MHz SUNW,UltraSPARC-T2+ on-line
52 1414 MHz SUNW,UltraSPARC-T2+ on-line
53 1414 MHz SUNW,UltraSPARC-T2+ on-line
54 1414 MHz SUNW,UltraSPARC-T2+ on-line
55 1414 MHz SUNW,UltraSPARC-T2+ on-line
56 1414 MHz SUNW,UltraSPARC-T2+ on-line
57 1414 MHz SUNW,UltraSPARC-T2+ on-line
58 1414 MHz SUNW,UltraSPARC-T2+ on-line
59 1414 MHz SUNW,UltraSPARC-T2+ on-line
60 1414 MHz SUNW,UltraSPARC-T2+ on-line
61 1414 MHz SUNW,UltraSPARC-T2+ on-line
62 1414 MHz SUNW,UltraSPARC-T2+ on-line
63 1414 MHz SUNW,UltraSPARC-T2+ on-line
64 1414 MHz SUNW,UltraSPARC-T2+ on-line
65 1414 MHz SUNW,UltraSPARC-T2+ on-line
66 1414 MHz SUNW,UltraSPARC-T2+ on-line
67 1414 MHz SUNW,UltraSPARC-T2+ on-line
68 1414 MHz SUNW,UltraSPARC-T2+ on-line
69 1414 MHz SUNW,UltraSPARC-T2+ on-line
70 1414 MHz SUNW,UltraSPARC-T2+ on-line
71 1414 MHz SUNW,UltraSPARC-T2+ on-line
72 1414 MHz SUNW,UltraSPARC-T2+ on-line
73 1414 MHz SUNW,UltraSPARC-T2+ on-line
74 1414 MHz SUNW,UltraSPARC-T2+ on-line
75 1414 MHz SUNW,UltraSPARC-T2+ on-line
76 1414 MHz SUNW,UltraSPARC-T2+ on-line
77 1414 MHz SUNW,UltraSPARC-T2+ on-line
78 1414 MHz SUNW,UltraSPARC-T2+ on-line
79 1414 MHz SUNW,UltraSPARC-T2+ on-line
80 1414 MHz SUNW,UltraSPARC-T2+ on-line
81 1414 MHz SUNW,UltraSPARC-T2+ on-line
82 1414 MHz SUNW,UltraSPARC-T2+ on-line
83 1414 MHz SUNW,UltraSPARC-T2+ on-line
84 1414 MHz SUNW,UltraSPARC-T2+ on-line
85 1414 MHz SUNW,UltraSPARC-T2+ on-line
86 1414 MHz SUNW,UltraSPARC-T2+ on-line
87 1414 MHz SUNW,UltraSPARC-T2+ on-line
88 1414 MHz SUNW,UltraSPARC-T2+ on-line
89 1414 MHz SUNW,UltraSPARC-T2+ on-line
90 1414 MHz SUNW,UltraSPARC-T2+ on-line
91 1414 MHz SUNW,UltraSPARC-T2+ on-line
92 1414 MHz SUNW,UltraSPARC-T2+ on-line
93 1414 MHz SUNW,UltraSPARC-T2+ on-line
94 1414 MHz SUNW,UltraSPARC-T2+ on-line
95 1414 MHz SUNW,UltraSPARC-T2+ on-line
96 1414 MHz SUNW,UltraSPARC-T2+ on-line
97 1414 MHz SUNW,UltraSPARC-T2+ on-line
98 1414 MHz SUNW,UltraSPARC-T2+ on-line
99 1414 MHz SUNW,UltraSPARC-T2+ on-line
100 1414 MHz SUNW,UltraSPARC-T2+ on-line
101 1414 MHz SUNW,UltraSPARC-T2+ on-line
102 1414 MHz SUNW,UltraSPARC-T2+ on-line
103 1414 MHz SUNW,UltraSPARC-T2+ on-line
104 1414 MHz SUNW,UltraSPARC-T2+ on-line
105 1414 MHz SUNW,UltraSPARC-T2+ on-line
106 1414 MHz SUNW,UltraSPARC-T2+ on-line
107 1414 MHz SUNW,UltraSPARC-T2+ on-line
108 1414 MHz SUNW,UltraSPARC-T2+ on-line
109 1414 MHz SUNW,UltraSPARC-T2+ on-line
110 1414 MHz SUNW,UltraSPARC-T2+ on-line
111 1414 MHz SUNW,UltraSPARC-T2+ on-line
112 1414 MHz SUNW,UltraSPARC-T2+ on-line
113 1414 MHz SUNW,UltraSPARC-T2+ on-line
114 1414 MHz SUNW,UltraSPARC-T2+ on-line
115 1414 MHz SUNW,UltraSPARC-T2+ on-line
116 1414 MHz SUNW,UltraSPARC-T2+ on-line
117 1414 MHz SUNW,UltraSPARC-T2+ on-line
118 1414 MHz SUNW,UltraSPARC-T2+ on-line
119 1414 MHz SUNW,UltraSPARC-T2+ on-line
120 1414 MHz SUNW,UltraSPARC-T2+ on-line
121 1414 MHz SUNW,UltraSPARC-T2+ on-line
122 1414 MHz SUNW,UltraSPARC-T2+ on-line
123 1414 MHz SUNW,UltraSPARC-T2+ on-line
124 1414 MHz SUNW,UltraSPARC-T2+ on-line
125 1414 MHz SUNW,UltraSPARC-T2+ on-line
126 1414 MHz SUNW,UltraSPARC-T2+ on-line
127 1414 MHz SUNW,UltraSPARC-T2+ on-line
======================= Physical Memory Configuration ========================
Segment Table:
--------------------------------------------------------------
Base Segment Interleave Bank Contains
Address Size Factor Size Modules
--------------------------------------------------------------
0x0 32 GB 8 4 GB MB/CPU0/CMP0/BR0/CH0/D0
MB/CPU0/CMP0/BR0/CH1/D0
4 GB MB/CPU0/CMP0/BR1/CH0/D0
MB/CPU0/CMP0/BR1/CH1/D0
4 GB MB/MEM0/CMP0/BR0/CH0/D1
MB/MEM0/CMP0/BR0/CH1/D1
4 GB MB/MEM0/CMP0/BR1/CH0/D1
MB/MEM0/CMP0/BR1/CH1/D1
4 GB MB/CPU1/CMP1/BR0/CH0/D0
MB/CPU1/CMP1/BR0/CH1/D0
4 GB MB/CPU1/CMP1/BR1/CH0/D0
MB/CPU1/CMP1/BR1/CH1/D0
4 GB MB/MEM1/CMP1/BR0/CH0/D1
MB/MEM1/CMP1/BR0/CH1/D1
4 GB MB/MEM1/CMP1/BR1/CH0/D1
MB/MEM1/CMP1/BR1/CH1/D1
================================ IO Devices ================================
Slot + Bus Name + Model
Status Type Path
----------------------------------------------------------------------------
MB/HBA PCIE scsi-pciex1000,58 LSI,1068E
/pci@400/pci@0/pci@1/scsi@0
MB/PCIE0 PCIE network-pciex8086,105f SUNW,pcie-northstar
/pci@400/pci@0/pci@d/network@0
MB/PCIE0 PCIE network-pciex8086,105f SUNW,pcie-northstar
/pci@400/pci@0/pci@d/network@0,1
MB/NET0 PCIE network-pciex108e,abcd SUNW,pcie-neptune
/pci@500/pci@0/pci@c/network@0
MB/NET1 PCIE network-pciex108e,abcd SUNW,pcie-neptune
/pci@500/pci@0/pci@c/network@0,1
MB/NET2 PCIE network-pciex108e,abcd SUNW,pcie-neptune
/pci@500/pci@0/pci@c/network@0,2
MB/NET3 PCIE network-pciex108e,abcd SUNW,pcie-neptune
/pci@500/pci@0/pci@c/network@0,3
MB PCIX usb-pciclass,0c0310
/pci@400/pci@0/pci@9/pci@0/usb@0
MB PCIX usb-pciclass,0c0310
/pci@400/pci@0/pci@9/pci@0/usb@0,1
MB PCIX usb-pciclass,0c0320
/pci@400/pci@0/pci@9/pci@0/usb@0,2
============================ Environmental Status ============================
Fan sensors:
----------------------------------------------------------------
Location Sensor Status
----------------------------------------------------------------
SYS/MB/FT0 TACH ok
SYS/MB/FT1 TACH ok
SYS/MB/FT2 TACH ok
SYS/MB/FT3 TACH ok
Fan indicators:
----------------------------------------------------------------
Location Sensor Condition
----------------------------------------------------------------
SYS/PS0 FAN_FAULT ok
SYS/PS1 FAN_FAULT ok
SYS/PS2 FAN_FAULT ok
SYS/PS3 FAN_FAULT ok
Temperature sensors:
----------------------------------------------------------------
Location Sensor Status
----------------------------------------------------------------
SYS/MB T_MB2 ok
SYS/MB/CPU0 T_CPU_INLET ok
SYS/MB/CPU0 T_VF_TOP ok
SYS/MB/CPU1 T_CPU_INLET ok
SYS/MB/CPU1 T_VF_TOP ok
SYS T_AMB ok
Temperature indicators:
----------------------------------------------------------------
Location Indicator Condition
----------------------------------------------------------------
SYS/PS0 TEMP_FAULT ok
SYS/PS1 TEMP_FAULT ok
SYS/PS2 TEMP_FAULT ok
SYS/PS3 TEMP_FAULT ok
Current sensors:
----------------------------------------------------------------
Location Sensor Status
----------------------------------------------------------------
SYS/MB/CPU0/DVRM_CORE I_+1V1 ok
SYS/MB/CPU1/DVRM_CORE I_+1V1 ok
SYS/PS0 I_+12V ok
SYS/PS0 I_AC ok
SYS/PS0 I_AC_LIMIT ok
SYS/PS0 I_DC_LIMIT ok
SYS/PS1 I_+12V ok
SYS/PS1 I_AC ok
SYS/PS1 I_AC_LIMIT ok
SYS/PS1 I_DC_LIMIT ok
SYS/PS2 I_+12V ok
SYS/PS2 I_AC ok
SYS/PS2 I_AC_LIMIT ok
SYS/PS2 I_DC_LIMIT ok
SYS/PS3 I_+12V ok
SYS/PS3 I_AC ok
SYS/PS3 I_AC_LIMIT ok
SYS/PS3 I_DC_LIMIT ok
Current indicators:
----------------------------------------------------------------
Location Indicator Condition
----------------------------------------------------------------
SYS/PS0 CUR_FAULT ok
SYS/PS1 CUR_FAULT ok
SYS/PS2 CUR_FAULT ok
SYS/PS3 CUR_FAULT ok
Voltage sensors:
----------------------------------------------------------------
Location Sensor Status
----------------------------------------------------------------
SYS/MB/SP V_+3V3STBY ok
SYS/MB/SP V_+3V3REG ok
SYS/MB/DVRM_PLX V_+1V0 ok
SYS/MB/DVRM_ZAM23 V_+1V1 ok
SYS/MB/DVRM_ZAM01 V_+1V1 ok
SYS/MB/DVRM_ZAMP V_+1V5 ok
SYS/MB/DVRM_33 V_+3V3 ok
SYS/MB V_+12V ok
SYS/MB V_PHY+2V5 ok
SYS/MB V_NEP+1V2 ok
SYS/MB V_MAIN+3V3 ok
SYS/MB/CPU0/DVRM_CORE V_+1V1 ok
SYS/MB/CPU0/DVRM_FBD V_+1V8 ok
SYS/MB/CPU0/DVRM_15 V_+1V5 ok
SYS/MB/CPU1/DVRM_CORE V_+1V1 ok
SYS/MB/CPU1/DVRM_FBD V_+1V8 ok
SYS/MB/CPU1/DVRM_15 V_+1V5 ok
SYS/MB/MEM0/DVRM_15 V_+1V5 ok
SYS/MB/MEM0/DVRM_FBD V_+1V8 ok
SYS/MB/MEM1/DVRM_15 V_+1V5 ok
SYS/MB/MEM1/DVRM_FBD V_+1V8 ok
SYS/PS0 V_+12V ok
SYS/PS0 V_AC ok
SYS/PS1 V_+12V ok
SYS/PS1 V_AC ok
SYS/PS2 V_+12V ok
SYS/PS2 V_AC ok
SYS/PS3 V_+12V ok
SYS/PS3 V_AC ok
Voltage indicators:
----------------------------------------------------------------
Location Indicator Condition
----------------------------------------------------------------
SYS/MB/SP V_+3VBATT ok
SYS/PS0 AC_POK ok
SYS/PS0 DC_POK ok
SYS/PS0 VOLT_FAULT ok
SYS/PS1 AC_POK ok
SYS/PS1 DC_POK ok
SYS/PS1 VOLT_FAULT ok
SYS/PS2 AC_POK ok
SYS/PS2 DC_POK ok
SYS/PS2 VOLT_FAULT ok
SYS/PS3 AC_POK ok
SYS/PS3 DC_POK ok
SYS/PS3 VOLT_FAULT ok
LEDs:
----------------------------------------------------------------
Location LED State
----------------------------------------------------------------
SYS SERVICE steady
SYS LOCATE off
SYS ACT steady
SYS PS_FAULT off
SYS TEMP_FAULT off
SYS FAN_FAULT off
SYS/MB/CPU0/CMP0/BR0/CH0/D0 SERVICE off
SYS/MB/CPU0/CMP0/BR0/CH1/D0 SERVICE off
SYS/MB/CPU0/CMP0/BR1/CH0/D0 SERVICE off
SYS/MB/CPU0/CMP0/BR1/CH1/D0 SERVICE off
SYS/MB/CPU0 SERVICE steady
SYS/MB/CPU1/CMP1/BR0/CH0/D0 SERVICE off
SYS/MB/CPU1/CMP1/BR0/CH1/D0 SERVICE off
SYS/MB/CPU1/CMP1/BR1/CH0/D0 SERVICE off
SYS/MB/CPU1/CMP1/BR1/CH1/D0 SERVICE off
SYS/MB/CPU1 SERVICE off
SYS/MB/MEM0/CMP0/BR0/CH0/D1 SERVICE off
SYS/MB/MEM0/CMP0/BR0/CH1/D1 SERVICE off
SYS/MB/MEM0/CMP0/BR1/CH0/D1 SERVICE off
SYS/MB/MEM0/CMP0/BR1/CH1/D1 SERVICE off
SYS/MB/MEM0 SERVICE off
SYS/MB/MEM1/CMP1/BR0/CH0/D1 SERVICE off
SYS/MB/MEM1/CMP1/BR0/CH1/D1 SERVICE off
SYS/MB/MEM1/CMP1/BR1/CH0/D1 SERVICE off
SYS/MB/MEM1/CMP1/BR1/CH1/D1 SERVICE off
SYS/MB/MEM1 SERVICE off
SYS/MB/FT0 SERVICE off
SYS/MB/FT1 SERVICE off
SYS/MB/FT2 SERVICE off
SYS/MB/FT3 SERVICE off
SYS/HDD0 SERVICE off
SYS/HDD0 OK2RM off
SYS/HDD1 SERVICE off
SYS/HDD1 OK2RM off
SYS/HDD2 SERVICE off
SYS/HDD2 OK2RM off
SYS/HDD3 SERVICE off
SYS/HDD3 OK2RM off
============================ FRU Status ============================
Location Name Status
------------------------------------------------------
SYS MB enabled
SYS/MB SP enabled
SYS/MB SCC_NVRAM enabled
SYS/MB CPU0 enabled
SYS/MB/CPU0/CMP0/BR0/CH0 D0 enabled
SYS/MB/CPU0/CMP0/BR0/CH1 D0 enabled
SYS/MB/CPU0/CMP0/BR1/CH0 D0 enabled
SYS/MB/CPU0/CMP0/BR1/CH1 D0 enabled
SYS/MB CPU1 enabled
SYS/MB/CPU1/CMP1/BR0/CH0 D0 enabled
SYS/MB/CPU1/CMP1/BR0/CH1 D0 enabled
SYS/MB/CPU1/CMP1/BR1/CH0 D0 enabled
SYS/MB/CPU1/CMP1/BR1/CH1 D0 enabled
SYS/MB MEM0 enabled
SYS/MB/MEM0/CMP0/BR0/CH0 D1 enabled
SYS/MB/MEM0/CMP0/BR0/CH1 D1 enabled
SYS/MB/MEM0/CMP0/BR1/CH0 D1 enabled
SYS/MB/MEM0/CMP0/BR1/CH1 D1 enabled
SYS/MB MEM1 enabled
SYS/MB/MEM1/CMP1/BR0/CH0 D1 enabled
SYS/MB/MEM1/CMP1/BR0/CH1 D1 enabled
SYS/MB/MEM1/CMP1/BR1/CH0 D1 enabled
SYS/MB/MEM1/CMP1/BR1/CH1 D1 enabled
SYS/MB FT0 enabled
SYS/MB FT1 enabled
SYS/MB FT2 enabled
SYS/MB FT3 enabled
SYS HDD0 enabled
SYS HDD1 enabled
SYS HDD2 enabled
SYS HDD3 enabled
SYS DVD enabled
SYS USBBD enabled
SYS PS0 enabled
SYS PS1 enabled
SYS PS2 enabled
SYS PS3 enabled
============================ FW Version ============================
Version
------------------------------------------------------------
Sun System Firmware 7.4.0.b 2011/05/17 13:24
====================== System PROM revisions =======================
Version
------------------------------------------------------------
OBP 4.33.0.b 2011/05/16 16:28
Chassis Serial Number
---------------------
<redacted>