No, your RAID controller is only connected to your DVD drive. If it does go bad, just your DVD drive won't work. Your disks should remain unaffected. Assuming your LPARs are multipathed and have network connections going through each VIO server, if one of your SAS Adapters does go bad, the VIO server using it will go down till the parts are replaced, but since you have dual VIO servers, your LPARs should move their connections through the other VIO server that is still running and be fine. They'll throw a lot of errors in the errpt, but should continue to run.
10 More Discussions You Might Find Interesting
1. AIX
I have a script running remotely using viosvrcmd command on hmc to back up the VIO servers. these are the steps involved
1. Mount the NFS directory on to the VIO server
2. run backupios command
3. un mount the directory
I am stuck up in the 3rd step. I am not able to unmount the nfs... (6 Replies)
Discussion started by: balaji_prk
6 Replies
2. AIX
Hi,
I want to know wheather partition size for installation of vio client can be specified on vio server
example
If I am installing vio server on blade with 2*300gb hard disk,after that I want to create 2 vio client (AIX Operating system) wheather I can specify hard disk size while... (1 Reply)
Discussion started by: manoj.solaris
1 Replies
3. AIX
Hi Guys,
I'm working on building a new 595 machine.. I'm try to achieve high availability for the VIO clients using 2 VIO servers, The ethernet part is satisfied using SEA failover, Now how do I achieve redundancy for the disks, its the servers internal disk attached to the scsi cards...
... (2 Replies)
Discussion started by: kkeng808
2 Replies
4. AIX
I have same lun (hdisk3) assigned to 2 vios server (dual vio server) and this is mapped to the client lpar. I have sddpcm on the VIO.
On the VIOA, the attributes for fscsi1 and fscsi3 are set to fast_fail and dyntrk is set to yes
Now, if I do a lqueryvg -Atp on the hdisk3, I get a "DISK... (4 Replies)
Discussion started by: mk8570
4 Replies
5. AIX
Hi
In the vio server when I do # lsattr -El hdisk*, I get a PVID. The same PVID is also seen when I put the lspv command on the vio client partition. This way Im able to confirm the lun using the PVID.
Similarly how does the vio client partition gets the virtual ethernet scsi client adapter... (1 Reply)
Discussion started by: newtoaixos
1 Replies
6. AIX
Hi,
I am facing an issue in vio server. When I run
bosboot -ad /dev/hdisk0
I am getting an error
trustchk: Verification of attributes failed: /usr/sbin/bootinfo
: accessauths
regards,
vjm
Please use code tags next time for your code and data. (8 Replies)
Discussion started by: vjm
8 Replies
7. UNIX for Dummies Questions & Answers
Hi,
So I downloaded this kernel source and was able to build it successfully.
But I want to add this SDK source code inside, can anyone help me how to do this? Note that the SDK source can be built by itself.
I added the SDK in the main Makefile:
init-y := init/
#added SDK... (0 Replies)
Discussion started by: h0ujun
0 Replies
8. Shell Programming and Scripting
Hi
I have a build.xml file and I can run it on Windows via cmd. Now I want to write a script to invoke the same. Is there a way to do this? (1 Reply)
Discussion started by: ankur328
1 Replies
9. AIX
We've got two datacenters and in every datacenter 2 VIOs.
The VIO manages the I/O of the LPARs. So: Is it possible to reboot the VIO without shuting down an LPAR:wall: (4 Replies)
Discussion started by: DiViN3
4 Replies
10. Windows & DOS: Issues & Discussions
Hi Team,
My new build configuration always looking for the files from the build where i copied from.
please help me to resolve this.
I am using Visual studio 2008.It has Qt 4.8. plugins,qml,C++ development
I created new debug_new build configuration with additional preprocessor from the... (1 Reply)
Discussion started by: SA_Palani
1 Replies
vxpfto(1M) vxpfto(1M)
NAME
vxpfto - set Powerfail Timeout (pfto)
SYNOPSIS
vxpfto -g diskgroup -t timeout
vxpfto [-g diskgroup] -t timeout volume_list
vxpfto [-g diskgroup] -o pftostate={enabled|disabled}
vxpfto [-g diskgroup] -o pftostate={enabled|disabled} volume_list
DESCRIPTION
Powerfail Timeout is an attribute of a SCSI disk connected to an HP-UX host (see the pfto(7) man page). The vxpfto command sets the Power-
fail Timeout interval on a set of Volume Manager disks, either all disks in a disk group, or all disks underlying the volumes listed.
The first form of the command sets the same PFTO value for all the disks in the specified VxVM diskgroup.
In the second form, all disks underlying the given list of volumes are selected, optionally restricted by the disk group specified with the
-g option. If you specify a diskgroup, any volume in the list not belonging to the diskgroup is ignored.
Use the -o pftostate option to disable or enable PFTO. By default, PFTO is enabled. You can enable PFTO either on all disks in a disk
group, or on all disks underlying the volumes listed.
If you invoke vxpfto without arguments, it displays a usage message.
OPTIONS
-g diskgroup
Specifies the disk group for the operation, either by disk group ID or by disk group name.
-o pftostate={enabled|disabled}
Enables or disables the use of PFTO for IO.
-t timeout
Specifies the PFTO value in seconds. The value must be zero or a positive integer. Zero represents the system default PFTO
value. The default value depends on the disk driver controlling the disk device.
volume_list
A list of VxVM volume names. List items must be separated by white-space.
EXIT CODES
vxpfto returns a zero if successful. If it encounters an error, vxpfto exits and displays a message on standard error. Defined exit codes
are:
0 Success.
1 No PFTO value specified.
2 No diskgroup or volume list specified.
3 Illegal PFTO value specified.
EXAMPLES
Set the PFTO value on all disks in disk group testdg to 100 seconds:
vxpfto -t 100 -g testdg
Set the PFTO value to 50 seconds on all disks underlying volume01 and volume02 in disk group testdg:
vxpfto -t 50 -g testdg volume01 volume02
Set the PFTO value to 300 seconds on all disks underlying volume01 and volume02, even though they are not in the same disk group:
vxpfto -t 300 volume01 volume02
Disable PFTO on all disks in disk group testdg:
vxpfto -g testdg -o pftostate=disabled
Enable PFTO on all disks underlying volume01 and volume02i in disk group testdg:
vxpfto -g testdg -o pftostate=enabled volume01 volume02
SEE ALSO
vxdisk(1M), pfto(7)
VxVM 5.0.31.1 24 Mar 2008 vxpfto(1M)