Old 07-18-2011
Yes, DVD is attached to the Raid controller. For installing the second VIO I had to move the Raid controller to the other LPAR to get the DVD rom moved over.

I guess I am confused about how the SAS adapter function is ? My understanding is that RAID controller controls or maintains parity for the i/O to the disk.

So, does this mean that if the RAID controller goes bad, will it affect all the disks.
 

10 More Discussions You Might Find Interesting

1. AIX

Backup of VIO

I have a script running remotely using viosvrcmd command on hmc to back up the VIO servers. these are the steps involved 1. Mount the NFS directory on to the VIO server 2. run backupios command 3. un mount the directory I am stuck up in the 3rd step. I am not able to unmount the nfs... (6 Replies)
Discussion started by: balaji_prk
6 Replies

2. AIX

vio server and vio client

Hi, I want to know wheather partition size for installation of vio client can be specified on vio server example If I am installing vio server on blade with 2*300gb hard disk,after that I want to create 2 vio client (AIX Operating system) wheather I can specify hard disk size while... (1 Reply)
Discussion started by: manoj.solaris
1 Replies

3. AIX

VIO Redundancy

Hi Guys, I'm working on building a new 595 machine.. I'm try to achieve high availability for the VIO clients using 2 VIO servers, The ethernet part is satisfied using SEA failover, Now how do I achieve redundancy for the disks, its the servers internal disk attached to the scsi cards... ... (2 Replies)
Discussion started by: kkeng808
2 Replies

4. AIX

sddpcm on vio

I have same lun (hdisk3) assigned to 2 vios server (dual vio server) and this is mapped to the client lpar. I have sddpcm on the VIO. On the VIOA, the attributes for fscsi1 and fscsi3 are set to fast_fail and dyntrk is set to yes Now, if I do a lqueryvg -Atp on the hdisk3, I get a "DISK... (4 Replies)
Discussion started by: mk8570
4 Replies

5. AIX

vio server ethernet to vio client ethernet(concepts confusing)

Hi In the vio server when I do # lsattr -El hdisk*, I get a PVID. The same PVID is also seen when I put the lspv command on the vio client partition. This way Im able to confirm the lun using the PVID. Similarly how does the vio client partition gets the virtual ethernet scsi client adapter... (1 Reply)
Discussion started by: newtoaixos
1 Replies

6. AIX

VIO Server

Hi, I am facing an issue in vio server. When I run bosboot -ad /dev/hdisk0 I am getting an error trustchk: Verification of attributes failed: /usr/sbin/bootinfo : accessauths regards, vjm Please use code tags next time for your code and data. (8 Replies)
Discussion started by: vjm
8 Replies

7. UNIX for Dummies Questions & Answers

Adding SDK Build on Kernel Source Build

Hi, So I downloaded this kernel source and was able to build it successfully. But I want to add this SDK source code inside, can anyone help me how to do this? Note that the SDK source can be built by itself. I added the SDK in the main Makefile: init-y := init/ #added SDK... (0 Replies)
Discussion started by: h0ujun
0 Replies

8. Shell Programming and Scripting

Build.xml invocation by Build Script

Hi I have a build.xml file and I can run it on Windows via cmd. Now I want to write a script to invoke the same. Is there a way to do this? (1 Reply)
Discussion started by: ankur328
1 Replies

9. AIX

Reboot VIO - OK?

We've got two datacenters and in every datacenter 2 VIOs. The VIO manages the I/O of the LPARs. So: Is it possible to reboot the VIO without shuting down an LPAR:wall: (4 Replies)
Discussion started by: DiViN3
4 Replies

10. Windows & DOS: Issues & Discussions

(VS 2008) New build config looking files from other folder build config

Hi Team, My new build configuration always looking for the files from the build where i copied from. please help me to resolve this. I am using Visual studio 2008.It has Qt 4.8. plugins,qml,C++ development I created new debug_new build configuration with additional preprocessor from the... (1 Reply)
Discussion started by: SA_Palani
1 Replies
vxdiskadd(1M)															     vxdiskadd(1M)

NAME
vxdiskadd - add one or more disks for use with Veritas Volume Manager SYNOPSIS
vxdiskadd disk_address_pattern_list DESCRIPTION
The vxdiskadd utility configures disks for use by Veritas Volume Manager (VxVM). Disks must already have been formatted. vxdiskadd prompts the user for a disk group name and disk name for the disks. If no disk group name specified, the disks will be left as unassigned replacement disks for future use. A new disk group may be created that will become the disks' disk group. If a disk group is specified for the disks, the user is prompted for whether the disks should be designated as spares for the disk group. For new disks, all space on the disk becomes free space in the disk's disk group. vxdiskadd interactively allows initialization to be done for all the disks specified or allows the user to ask to make the decision for each disk individually. One or more disks may be specified with a disk_address_pattern_list. The basic form of a disk address is c#t#d#. Any leading portion of this address may be specified to indicate that all disks that match that leading portion should be used. For example c2t0 may be used to specify all disks on controller 2, target 0. More than one disk address or address pattern may be specified on the command line. In case of enclosure-based names, the disk address will be of the form enclosurename_diskno. The enclosurename indicates that all disks in the specified enclosure are used. For example, emc1_ is used to specify all disks in the enclosure emc1. The word all may be used to specify all disks on the system. Disk address names relate directly to device node names in the /dev/dmp and /dev/rdmp directories. Here are more examples: all: all disks c3 c4t2: all disks on controller 3 and controller 4, target 2 c3t4d2: a single disk (in the c#t#d# naming scheme) xyz_0 : a single disk (in the enclosure based naming scheme) xyz_ : all disks on the enclosure whose name is xyz The files /etc/vx/cntrls.exclude, /etc/vx/disks.exclude and /etc/vx/enclr.exclude may be used to exclude controllers or disks from use by vxdiskadd. Each line of cntrls.exclude specifies the address of a controller to exclude, for example, c2. Each line of disks.exclude spec- ifies a disk to exclude, for example, c0t3d0. Each line of enclr.exclude specifies the name of an enclosure to exclude, for example, enc0. All courses of action that do not involve clear failure conditions require prompts from the user, with defaults supplied as appropriate. Help is made available at every prompt. Entering ? in response to a prompt displays a context-sensitive help message. OPERATIONS
Reconnecting a drive that was temporarily inaccessible This situation is detected automatically by noting that the specified drive has a disk ID that matches a disk media record with no currently associated physical disk. After reconnection, any stale plexes referring the disk are reattached, and any stopped volumes referring the disk are restarted. This reattach action is performed by calling the vxrecover utility. Initialization of a disk with reserved regions Initialization of the disk is performed by calling vxdisksetup. Adding a disk to an existing disk group This operation can be performed independently of the initialization of the disk drive. The operation adds the disk to the group so that its storage is added to the free space pool in that disk group. The vxassist utility can subsequently allocate from that free space. Creation of new disk groups in which to import a new disk If disks are added that are required to be put into a disk group that does not exist, the option of creating the disk group is offered. Hardware-Specific Note Some environments provide guidelines to optimize VxVM's interaction with intelligent storage systems. If these guidelines are present, VxVM follows the guidelines when adding disks to disk groups. If the operation fails due to these guideline(s), you are prompted to use the force option. The force option ignores any such storage-specific guidelines. FILES
/etc/vx/cntrls.exclude Specifies the address of controllers to exclude from vxdiskadd operations. /etc/vx/disks.exclude Specifies the address of disks to exclude from vxdiskadd operations. /etc/vx/enclr.exclude Specifies the address of enclosures to exclude from vxdiskadd operations. NOTES
EFI disks cannot be added to a disk group that is compatible with the Cross-platform Data Sharing (CDS) feature, nor can they be formatted as CDS disks. SEE ALSO
vxassist(1M), vxdisk(1M), vxdiskadm(1M), vxdisksetup(1M), vxintro(1M), vxrecover(1M) VxVM 5.0.31.1 24 Mar 2008 vxdiskadd(1M)