Sponsored Content
Full Discussion: Vio Build
Operating Systems AIX Vio Build Post 302538976 by kah00na on Thursday 14th of July 2011 05:11:50 PM
Old 07-14-2011
Find the parent of hdisk0 on both of your vio servers and run a "lscfg -vl sas#" against both of them and that will tell you what slots the hdisks are connected to and you can see what is in those slots.... Here's an example of what I'm talking about:
Code:
vio1:/:# lsdev -l hdisk0 -F parent
sas0
vio1:/:# lscfg -vl sas0
  sas0             U78AA.001.XXXXXXX-P1-T9  Controller SAS Protocol

Code:
vio2:/:# lsdev -l hdisk0 -F parent
sas1
vio2:/:# lscfg -vl sas1
  sas1             U78AA.001.XXXXXXX-P1-C19-T1  Controller SAS Protocol

vio1 is getting it disks from the adapter in P1-T9. vio2 is getting its disks from the adapter in P1-C19-T1. Those are my RAID controllers.
 

10 More Discussions You Might Find Interesting

1. AIX

Backup of VIO

I have a script running remotely using viosvrcmd command on hmc to back up the VIO servers. these are the steps involved 1. Mount the NFS directory on to the VIO server 2. run backupios command 3. un mount the directory I am stuck up in the 3rd step. I am not able to unmount the nfs... (6 Replies)
Discussion started by: balaji_prk
6 Replies

2. AIX

vio server and vio client

Hi, I want to know wheather partition size for installation of vio client can be specified on vio server example If I am installing vio server on blade with 2*300gb hard disk,after that I want to create 2 vio client (AIX Operating system) wheather I can specify hard disk size while... (1 Reply)
Discussion started by: manoj.solaris
1 Replies

3. AIX

VIO Redundancy

Hi Guys, I'm working on building a new 595 machine.. I'm try to achieve high availability for the VIO clients using 2 VIO servers, The ethernet part is satisfied using SEA failover, Now how do I achieve redundancy for the disks, its the servers internal disk attached to the scsi cards... ... (2 Replies)
Discussion started by: kkeng808
2 Replies

4. AIX

sddpcm on vio

I have same lun (hdisk3) assigned to 2 vios server (dual vio server) and this is mapped to the client lpar. I have sddpcm on the VIO. On the VIOA, the attributes for fscsi1 and fscsi3 are set to fast_fail and dyntrk is set to yes Now, if I do a lqueryvg -Atp on the hdisk3, I get a "DISK... (4 Replies)
Discussion started by: mk8570
4 Replies

5. AIX

vio server ethernet to vio client ethernet(concepts confusing)

Hi In the vio server when I do # lsattr -El hdisk*, I get a PVID. The same PVID is also seen when I put the lspv command on the vio client partition. This way Im able to confirm the lun using the PVID. Similarly how does the vio client partition gets the virtual ethernet scsi client adapter... (1 Reply)
Discussion started by: newtoaixos
1 Replies

6. AIX

VIO Server

Hi, I am facing an issue in vio server. When I run bosboot -ad /dev/hdisk0 I am getting an error trustchk: Verification of attributes failed: /usr/sbin/bootinfo : accessauths regards, vjm Please use code tags next time for your code and data. (8 Replies)
Discussion started by: vjm
8 Replies

7. UNIX for Dummies Questions & Answers

Adding SDK Build on Kernel Source Build

Hi, So I downloaded this kernel source and was able to build it successfully. But I want to add this SDK source code inside, can anyone help me how to do this? Note that the SDK source can be built by itself. I added the SDK in the main Makefile: init-y := init/ #added SDK... (0 Replies)
Discussion started by: h0ujun
0 Replies

8. Shell Programming and Scripting

Build.xml invocation by Build Script

Hi I have a build.xml file and I can run it on Windows via cmd. Now I want to write a script to invoke the same. Is there a way to do this? (1 Reply)
Discussion started by: ankur328
1 Replies

9. AIX

Reboot VIO - OK?

We've got two datacenters and in every datacenter 2 VIOs. The VIO manages the I/O of the LPARs. So: Is it possible to reboot the VIO without shuting down an LPAR:wall: (4 Replies)
Discussion started by: DiViN3
4 Replies

10. Windows & DOS: Issues & Discussions

(VS 2008) New build config looking files from other folder build config

Hi Team, My new build configuration always looking for the files from the build where i copied from. please help me to resolve this. I am using Visual studio 2008.It has Qt 4.8. plugins,qml,C++ development I created new debug_new build configuration with additional preprocessor from the... (1 Reply)
Discussion started by: SA_Palani
1 Replies
IIR(4)							   BSD Kernel Interfaces Manual 						    IIR(4)

NAME
iir -- Intel Integrated RAID controller and ICP Vortex driver SYNOPSIS
To compile this driver into the kernel, place the following lines in your kernel configuration file: device pci device scbus device iir Alternatively, to load the driver as a module at boot time, place the following line in loader.conf(5): iir_load="YES" DESCRIPTION
The iir driver claims to interface with the Intel integrated RAID controller cards, and all versions of the ICP Vortex controllers (including FC). HARDWARE
Controllers supported by the iir driver include: o Intel RAID Controller SRCMR o Intel Server RAID Controller U3-l (SRCU31a) o Intel Server RAID Controller U3-1L (SRCU31La) o Intel Server RAID Controller U3-2 (SRCU32) o All past and future releases of Intel and ICP RAID Controllers. o Intel RAID Controller SRCU21 (discontinued) o Intel RAID Controller SRCU31 (older revision, not compatible) o Intel RAID Controller SRCU31L (older revision, not compatible) The SRCU31 and SRCU31L can be updated via a firmware update available from Intel. SEE ALSO
cam(4), pass(4), xpt(4), camcontrol(8) AUTHORS
The iir driver is supported and maintained by Achim Leubner <Achim_Leubner@adaptec.com>. This manual page was written by Tom Rhodes <trhodes@FreeBSD.org> and is based on information supplied by the driver authors and the website of Mike Smith <msmith@FreeBSD.org>. BSD
August 8, 2004 BSD
All times are GMT -4. The time now is 10:32 AM.
Unix & Linux Forums Content Copyright 1993-2022. All Rights Reserved.
Privacy Policy