Sponsored Content
Operating Systems Linux Red Hat missing raid array after reboot Post 302529307 by oky on Thursday 9th of June 2011 03:33:03 AM
Old 06-09-2011
Did u checked whether your disks (sd [b|c] ) are available after the reboot...
 

9 More Discussions You Might Find Interesting

1. UNIX for Advanced & Expert Users

Percent complete error while scanning RAID array during 5.0.6 load

Percent complete SCO 5.0.6 / No longer an issue (0 Replies)
Discussion started by: Henrys
0 Replies

2. AIX

RAID level of array = false?

I created a RAID 5 array and when I list out the attributes of the "hdisk" it reports back raid_level = 5 but the RAID level of the array = false. What does this actually indicate about my array? I've never paid much attention to this until now since I have a disk reporting failure I want to make... (0 Replies)
Discussion started by: scottsl
0 Replies

3. UNIX for Advanced & Expert Users

Create RAID - Smart Array Tool - ML370

Hi guys, i must install an old old old ml370 server... I must create a RAID 5 with my 4 SCSI disk. I need a SmartStart disk for create it or a Floppy Disk called "Array configuration Tool". I don't find it on the hp website...:mad::mad::mad: Anyone have it?? Thanks in advance. Zio (0 Replies)
Discussion started by: Zio Bill
0 Replies

4. Solaris

EFI Disk labels on 3510 raid array

Hi Peeps, Can anyone help me an EFI lablel on a 3510 raid array that I cannot get rid of, format -e and label just asks you if you want to label it. Want an SMI label writing to it. Anyone got any ideas on how to remove the EFI label? Thanks in advance Martin (2 Replies)
Discussion started by: callmebob
2 Replies

5. Emergency UNIX and Linux Support

Loading a RAID array after OS crash

One of my very old drive farm servers had an OS fault and can't boot now but I'd like to restore some files from it. I tried booting Ubuntu from a CD, but it couldn't see the drives -- possibly because they're RAIDed together. Is there a good way to get at my files? The data in question is a... (2 Replies)
Discussion started by: CRGreathouse
2 Replies

6. Solaris

How to find missing disks on Sun x4150 without reboot?

Hi, Here is the issue: There are 4 disks on this Sun x4150 system under Solaris 10, but only 1 disk can be seen by the OS. I've tried commands disks and devfsadm but not working. It's an important production server, so 'reboot -r' is not a choice. # format < /dev/null Searching for... (6 Replies)
Discussion started by: aixlover
6 Replies

7. Fedora

Missing entries in log files just before/after reboot

Hello world, One of the servers, a Fedora one,rebooted today (Luckily, a testbox). I tried to get the reason the server rebooted. After going through the messages, I think that the log entries just before and after reboot are missing. Please below: (****** is the server name, for privacy... (0 Replies)
Discussion started by: satish51392111
0 Replies

8. Solaris

Solaris 10 Installation - Disks missing, and Raid

Hey everyone. First, let me start by saying I'm primarily focused on linux boxes, and just happened to get pulled into building two T5220's. I'm not super educated on sun boxes. Both T5220's have 8 146GB 15k SAS drives. Inside the service processor, I can run SHOW /SYS/HDD{0-7} and they all come... (2 Replies)
Discussion started by: msarro
2 Replies

9. UNIX for Advanced & Expert Users

Revive RAID 0 Array From Buffalo Duo NAS

Thank you in advanced, I had a Buffalo DUO crap out on me that was setup as RAID 0. I dont belive it was the drives but rather the controller in the DUO unit. I bought another external HDD enclosure and was able to fireup the two older DUO drives in it and I think I resembled the RAID... (12 Replies)
Discussion started by: metallica1973
12 Replies
CCDCONFIG(8)						    BSD System Manager's Manual 					      CCDCONFIG(8)

NAME
ccdconfig -- configuration utility for the concatenated disk driver SYNOPSIS
ccdconfig [-cv] ccd ileave [flags] dev ... ccdconfig -C [-v] [-f config_file] ccdconfig -u [-v] ccd ... ccdconfig -U [-v] [-f config_file] ccdconfig -g [ccd ...] DESCRIPTION
The ccdconfig utility is used to dynamically configure and unconfigure concatenated disk devices, or ccds. For more information about the ccd, see ccd(4). The options are as follows: -c Configure a ccd. This is the default behavior of ccdconfig. -C Configure all ccd devices listed in the ccd configuration file. -f config_file When configuring or unconfiguring all devices, read the file config_file instead of the default /etc/ccd.conf. -g Dump the current ccd configuration in a format suitable for use as the ccd configuration file. If no arguments are specified, every configured ccd is dumped. Otherwise, the configuration of each listed ccd is dumped. -u Unconfigure a ccd. -U Unconfigure all ccd devices listed the ccd configuration file. -v Cause ccdconfig to be verbose. A ccd is described on the command line and in the ccd configuration file by the name of the ccd, the interleave factor, the ccd configuration flags, and a list of one or more devices. The flags may be represented as a decimal number, a hexadecimal number, a comma-separated list of strings, or the word ``none''. The flags are as follows: CCDF_UNIFORM 0x02 Use uniform interleave CCDF_MIRROR 0x04 Support mirroring CCDF_NO_OFFSET 0x08 Do not use an offset CCDF_LINUX 0x0A Linux md(4) compatibility The format in the configuration file appears exactly as if it were entered on the command line. Note that on the command line and in the configuration file, the flags argument is optional. # # /etc/ccd.conf # Configuration file for concatenated disk devices # # ccd ileave flags component devices ccd0 16 none /dev/da2s1 /dev/da3s1 The component devices need to name partitions of type FS_BSDFFS (or ``4.2BSD'' as shown by disklabel(8)). If you want to use the Linux md(4) compatibility mode, please be sure to read the notes in ccd(4). FILES
/etc/ccd.conf default ccd configuration file EXAMPLES
A number of ccdconfig examples are shown below. The arguments passed to ccdconfig are exactly the same as you might place in the /etc/ccd.conf configuration file. The first example creates a 4-disk stripe out of four scsi disk partitions. The stripe uses a 64 sector interleave. The second example is an example of a complex stripe/mirror combination. It reads as a two disk stripe of da4 and da5 which is mirrored to a two disk stripe of da6 and da7. The last example is a simple mirror. The 2nd slice of /dev/da8 is mirrored with the 3rd slice of /dev/da9 and assigned to ccd0. # ccdconfig ccd0 64 none /dev/da0s1 /dev/da1s1 /dev/da2s1 /dev/da3s1 # ccdconfig ccd0 128 CCDF_MIRROR /dev/da4 /dev/da5 /dev/da6 /dev/da7 # ccdconfig ccd0 128 CCDF_MIRROR /dev/da8s2 /dev/da9s3 The following are matching commands in Linux and FreeBSD to create a RAID-0 in Linux and read it from FreeBSD. # Create a RAID-0 on Linux: mdadm --create --chunk=32 --level=0 --raid-devices=2 /dev/md0 /dev/hda1 /dev/hdb1 # Make the RAID-0 just created available on FreeBSD: ccdconfig -c /dev/ccd0 32 linux /dev/ada0s1 /dev/ada0s2 When you create a new ccd disk you generally want to fdisk(8) and disklabel(8) it before doing anything else. Once you create the initial label you can edit it, adding additional partitions. The label itself takes up the first 16 sectors of the ccd disk. If all you are doing is creating file systems with newfs, you do not have to worry about this as newfs will skip the label area. However, if you intend to dd(1) to or from a ccd partition it is usually a good idea to construct the partition such that it does not overlap the label area. For example, if you have A ccd disk with 10000 sectors you might create a 'd' partition with offset 16 and size 9984. # disklabel ccd0 > /tmp/disklabel.ccd0 # disklabel -Rr ccd0 /tmp/disklabel.ccd0 # disklabel -e ccd0 The disklabeling of a ccd disk is usually a one-time affair. If you reboot the machine and reconfigure the ccd disk, the disklabel you had created before will still be there and not require reinitialization. Beware that changing any ccd parameters: interleave, flags, or the device list making up the ccd disk, will usually destroy any prior data on that ccd disk. If this occurs it is usually a good idea to reini- tialize the label before [re]constructing your ccd disk. RECOVERY
An error on a ccd disk is usually unrecoverable unless you are using the mirroring option. But mirroring has its own perils: It assumes that both copies of the data at any given sector are the same. This holds true until a write error occurs or until you replace either side of the mirror. This is a poor-man's mirroring implementation. It works well enough that if you begin to get disk errors you should be able to backup the ccd disk, replace the broken hardware, and then regenerate the ccd disk. If you need more than this you should look into external hardware RAID SCSI boxes, RAID controllers (see GENERIC), or software RAID systems such as geom(8) and gvinum(8). SEE ALSO
dd(1), ccd(4), disklabel(8), fdisk(8), gvinum(8), rc(8) HISTORY
The ccdconfig utility first appeared in NetBSD 1.0A. BUGS
The initial disklabel returned by ccd(4) specifies only 3 partitions. One needs to change the number of partitions to 8 using ``disklabel -e'' to get the usual BSD expectations. BSD
October 1, 2013 BSD
All times are GMT -4. The time now is 04:12 AM.
Unix & Linux Forums Content Copyright 1993-2022. All Rights Reserved.