Operating Systems Solaris SunFire T2000 ipmievd error Post 302524885 by hergp on Wednesday 25th of May 2011 02:52:04 AM
Old 05-25-2011
Niagara Servers starting with the T5xxx series are equipped with ILOM - first as alternative to ALOM, then, since the T3 systems arrived, ILOM is the only management interface. Maybe Netra T2000 are equipped with ILOM too (found some references). The original T2000 only supports ALOM.
 

10 More Discussions You Might Find Interesting

1. Solaris

Network Path Not Found Error "Sunfire V100"

I recently got this new old server from a friend. I just installed a fresh version of Solaris 10 on it. I have put a static IP of 192.168.100.10 the server. Their is no subnetting scheme on the network. And I made the hostname "SunServ." And I also changed the folder "/etc/inet/hosts" because I... (4 Replies)
Discussion started by: louisd11
4 Replies

2. Solaris

Resolution error sunfire v245

Hi all, I am getting the below error on Solaris sunfire v245 server Error: can not display this video mode optimum resolution 1024x768 60Hz i am not able to resolve this .plz help me out ? (1 Reply)
Discussion started by: saurabh84g
1 Replies

3. Solaris

T2000 - Fault at MB/FF_POK

Hi all, I have a T2000 server which does not seem to respond when I power it on. Looking on the console I see the following: SC Alert: Host Power Failure: MB_DC_POK Fault SC Alert: Host system poweron failed due to fault at MB/FF_POK. SC Alert: VOLTAGE_SENSOR at MB/V_VCORE has exceeded... (4 Replies)
Discussion started by: jambalaya
4 Replies

4. Solaris

T2000 Hardware RAID

Hi, I have a root with hardware RAID on c0t0d0 and c0t2d0. I would like to set the boot device sequence in OBP for both hdds. I have checked in ls -l /dev/rdsk/ for the path of c0t2d0 but it does not exist. Can anyone shed some lights on this? AVAILABLE DISK SELECTIONS: 0.... (12 Replies)
Discussion started by: honmin
12 Replies

5. Solaris

Error while trying to boot from cdrom on Sun Fire T2000

Hi Guyz, I recently downloaded sol-10-u6-ga1-sparc-dvd.iso from Sun. I burned the disk as cd .iso. When trying to boot at the ok> boot cdrom i get the following error: ----------------------------------------------------------------------- Boot device:... (2 Replies)
Discussion started by: Mwamba
2 Replies

6. Solaris

SunFire V890 error -256 when boot

Hi all! I've a machine - SunFire V890, it've been failed by OS error for 2 weeks ago, and now, I must reinstall OS (Solaris 10 2009), the progress was successful, but when I reboot, it displayed the error like : Error -256: Last trap memory ... access aligned Error -256: Last trap memory... (1 Reply)
Discussion started by: trantuananh24hg
1 Replies

7. Solaris

Memory problems on a -sunfire T2000

I work with a network management tool, which, for various reasons, is installed on a solaris server.This is a Sunfire T2000 server with 16 CPUs and 8GB of RAM. I have installed a Solaris 10 ZFS and 8GB swap. From the beginning I had problems with memory occupation that it rises progressively to 95%... (4 Replies)
Discussion started by: drusa79
4 Replies

8. Hardware

Fan Tray for Sunfire T2000

Recently the rear fan assembly of one of our T2000 servers went faulty. I could replace it immediately with the one from a currently powered off standby machine. But now this one has to be replaced. So I got a quote from our supplier who charges EUR 776 for a new spare part or EUR 405 (all... (0 Replies)
Discussion started by: hergp
0 Replies

9. Solaris

Sun T2000 error codes

I got a Power supply failure. I replaced the power supply and still got the error. Any ideas on what I should try next? (1 Reply)
Discussion started by: 642fiddi
1 Replies

10. Hardware

POST error on SunFire V245

I've recently bought an SunFire V245. 2x 2.5ghz x64 4gb ram 4x 73gb sas hdd and... an blinking 'Identifior led' (white) with 'Service led' (amber) simultaneously. It boots for +- 5 secs and then the error occurd. Things done: Removed all hdd. Switched cpu Switched/removed ram... (2 Replies)
Discussion started by: niswier2222
2 Replies
strerr(8)						      System Manager's Manual							 strerr(8)

NAME
strerr - Receives error messages from the STREAMS log driver SYNOPSIS
/usr/sbin/strerr [-a sys_admin_mail_name] [-d logdir] PARAMETERS
Specifies the mail name of the user to receive the message via mail. This is the system administrator by default. Specifies the directory to contain the error log file. This is /var/adm/streams by default. DESCRIPTION
The strerr daemon receives error messages from the STREAMS log driver (strlog) for addition to the STREAMS error log files (error.mm.dd) in the STREAMS error logger directory (/var/adm/streams by default). When first called, the strerr daemon creates the log file error.mm.dd. This is a daily log file, where mm indicates the month and dd indicates the day of the logged messages. The strerr daemon then appends each error message that it subsequently receives from the STREAMS log driver to the log file. STREAMS error log messages have the following format: seq_num std_time ticks_time flags mod_ID sub_ID msg_text where: The error sequence number. The time the message was sent, in the format hh:mm:ss. The time the message was sent, measured in machine ticks since the last boot. Can be any of the following indicators: Indicates that the message has also been saved in the process's trace log. Indi- cates that the message signaled a fatal error. Indicates that the message is to be sent to the system administrator or specified user via mail. The module identification number of the trace message source. The subidentification number of the trace message source. The trace message text. The strerr daemon will run continuously until terminated by the user. FILES
The error log file or files on which strerr operates. NOTES
Only one strerr process can open the STREAMS log driver at a time. This restriction is intended to maximize performance. The STREAMS error logging mechanism works best when it is not overused. The strerr daemon can degrade STREAMS performance by affecting the response, throughput, and other behaviors of the drivers and modules that invoke it. The daemon will also fail to capture messages if drivers and modules generate messages at a higher rate than its optimum read rate. Missing sequence numbers among the messages in a log file indicate that messages have been lost. RELATED INFORMATION
Interfaces: strlog(7). delim off strerr(8)