I recently got this new old server from a friend. I just installed a fresh version of Solaris 10 on it. I have put a static IP of 192.168.100.10 the server. Their is no subnetting scheme on the network. And I made the hostname "SunServ." And I also changed the folder "/etc/inet/hosts" because I... (4 Replies)
Hi all,
I am getting the below error on Solaris sunfire v245 server
Error: can not display this video mode
optimum resolution 1024x768 60Hz
i am not able to resolve this .plz help me out ? (1 Reply)
Hi all,
I have a T2000 server which does not seem to respond when I power it on. Looking on the console I see the following:
SC Alert: Host Power Failure: MB_DC_POK Fault
SC Alert: Host system poweron failed due to fault at MB/FF_POK.
SC Alert: VOLTAGE_SENSOR at MB/V_VCORE has exceeded... (4 Replies)
Hi,
I have a root with hardware RAID on c0t0d0 and c0t2d0. I would like to set the boot device sequence in OBP for both hdds.
I have checked in ls -l /dev/rdsk/ for the path of c0t2d0 but it does not exist. Can anyone shed some lights on this?
AVAILABLE DISK SELECTIONS:
0.... (12 Replies)
Hi Guyz,
I recently downloaded sol-10-u6-ga1-sparc-dvd.iso from Sun. I burned the disk as cd .iso.
When trying to boot at the ok> boot cdrom
i get the following error:
-----------------------------------------------------------------------
Boot device:... (2 Replies)
Hi all!
I've a machine - SunFire V890, it've been failed by OS error for 2 weeks ago, and now, I must reinstall OS (Solaris 10 2009), the progress was successful, but when I reboot, it displayed the error like :
Error -256: Last trap memory ... access aligned
Error -256: Last trap memory... (1 Reply)
I work with a network management tool, which, for various reasons, is installed on a solaris server.This is a Sunfire T2000 server with 16 CPUs and 8GB of RAM. I have installed a Solaris 10 ZFS and 8GB swap. From the beginning I had problems with memory occupation that it rises progressively to 95%... (4 Replies)
Recently the rear fan assembly of one of our T2000 servers went faulty. I could replace it immediately with the one from a currently powered off standby machine. But now this one has to be replaced.
So I got a quote from our supplier who charges EUR 776 for a new spare part or EUR 405 (all... (0 Replies)
I've recently bought an SunFire V245.
2x 2.5ghz x64
4gb ram
4x 73gb sas hdd
and... an blinking 'Identifior led' (white) with 'Service led' (amber) simultaneously.
It boots for +- 5 secs and then the error occurd.
Things done:
Removed all hdd.
Switched cpu
Switched/removed ram... (2 Replies)
Discussion started by: niswier2222
2 Replies
LEARN ABOUT ULTRIX
elcsd
elcsd(8) System Manager's Manual elcsd(8)Name
elcsd - error logging daemon
Syntax
/etc/elcsd
Description
The daemon logs hardware and system-related error packets, or error messages, from the kernel errorlog buffer to the file syserr.<host-
name>. Hostname is the name of the local system. At system startup, the daemon is invoked out of For further information, see The daemon
must be running whenever the system is in multiuser mode.
To invoke the daemon in single-user mode, use the command with the -s option.
You can configure the daemon to log error packets locally from a remote ULTRIX host, or you can configure the daemon to send local error
packets to a remote system. Do this by changing the entries in the file. For further information, see The daemon uses an internet data-
gram socket to log information across systems.
Parameters related to such as the desired location for the errorlog file or files, as well as instructions for local and remote logging,
can be specified in the error logging configuration file, For further information, see
Restrictions
You must have superuser privileges to invoke the daemon.
Diagnostics
The daemon logs general status and error messages to in multiuser mode. This file is purged whenever the daemon is restarted.
FilesSee Alsoelcsd.conf(5), eli(8), rc(8), uerf(8)
Guide to the Error Logger
4th Berkeley Distributionelcsd(8)