Sponsored Content
Operating Systems SCO Change Disk controller in SCO 6.0.0 Post 302518156 by jgt on Thursday 28th of April 2011 06:09:04 PM
Old 04-28-2011
Quote:
The OS has to be configured to use the Megasas BTLD.
and how is that done, to my knowledge the OS discovers hardware by itself.
 

10 More Discussions You Might Find Interesting

1. Solaris

Controller target disk?

Hi, I am a newbie to Solaris. I want to know how to find out the controller target and disk number on a SunFire V890 box that has 6X72GB disks. The probe-scsi output is as shown below: /pci@8,600000/SUNW,qlc@2 LiD HA LUN --- Port WWN --- ----- Disk description ----- 0 0 0 ... (1 Reply)
Discussion started by: sudhir_shet
1 Replies

2. SCO

ultra 320 scsi raid controller driver for sco 5.0.6

I am facing a problem to install sco 5.0.6 in Dell Power Edge SC1420 which raid controller is ultra 320 scsi raid controller . how/from where to download the ultra 320 scsi raid controller driver for sco 5.0.6. Plz help with any idea karzon (1 Reply)
Discussion started by: karzon
1 Replies

3. SCO

Warning HD: no root disk controller was found

hi... i hav a problem to install sco unix while installing sco unix 5.0.5 in acer altos with hardware raid am getting error "Warning HD: no root disk controller was found system error 5: while getting fs type flushing controller: DAC960PRL cache done." i hav use the following... (18 Replies)
Discussion started by: mselvaprakash
18 Replies

4. SCO

SCO 5.0.7 no root disk controller found error during install

I'm "attempting" to install SCO 5.0.7 on an HP ML370 G4 server and am ready to bash the keyboard with head now. I keep getting the error message "WARNING hd: no root disk controller found" when running the bootable install cd. I have a raid 5 array with an online spare created using 4 36.3 GB... (2 Replies)
Discussion started by: FrictionBurn
2 Replies

5. UNIX for Dummies Questions & Answers

Samba change domain controller

Hello people i have a samba and they changed domain controller from a windows 2003 to a windows 2008, there is a problem with the version of samba maybe incompatibilities i dont know what show me this domain_client_validate: unable to validate password for user xxxx in domain xxxx to Domain... (0 Replies)
Discussion started by: enkei17
0 Replies

6. Solaris

Changed disk controller -> drops into GRUB?!

I changed disk controller. Unplugged every disk, inserted another controller card, an IBM M1015. The disks are recognized in BIOS, and the controller card's BIOS shows up. But after that, I drop into GRUB and a prompt. That is all. How shall I solve this problem? I am thinking of booting from... (2 Replies)
Discussion started by: kebabbert
2 Replies

7. Solaris

Disk controller reassignment

Hi The scenario in the oracle t4-1 hardware with solaris 10 is as follows: 1. The initial install on the server was performed with an incorrect disk layout. 2. New disks were ordered and slot into the server. 3. The disks are allocated a controller and a disk number based on the disk or... (13 Replies)
Discussion started by: kerrygold
13 Replies

8. SCO

How to change raid controller driver ? (hardware change)

Hello I'm trying to virtualize an instance of Sco Unix 5.0.5 in VirtualBox (called VM-A) , but sco I have problems set to launch with the new raid controller . The physical machine has a raid controller adaptec (alad driver) but VirtualBox uses buslogic (blc driver) What ... (3 Replies)
Discussion started by: flako
3 Replies

9. SCO

SCO 5.0.7 driver for HP SmartArray P410i Controller on Proliant DL380 G7?

Hi I hope this is the right forum. I am attempting to install SCO 5.0.7 on a Proliant DL380 G7 with a Smart Array P410I Controller. I need a driver for this. Can anybody point me to a download? Thanks in anticipation. (12 Replies)
Discussion started by: Stuart1946
12 Replies

10. SCO

SCO OS 6 Driver for LSIL SAS1064E Raid Controller

Hi all, A client has an SCO OpenServer Server 6.0, that is running on an HP ProLiant Box and they lost the root password. Its equipped with a Doal-Core Intel Pentium Processor. They don't have any media or emergency disk anymore. I tried to boot with the CD Rom, then "Tools", then exit to... (7 Replies)
Discussion started by: thm2222
7 Replies
vparutil(1M)															      vparutil(1M)

NAME
vparutil - get and set SCSI parameters for SCSI controllers from a virtual partition SYNOPSIS
dev_path dev_path dev_path scsi_id] scsi_rate] DESCRIPTION
The command gets and sets SCSI parameters for SCSI controllers within a running virtual partition. When setting the SCSI parameters using the option, the virtual partition which owns the specified SCSI controller must be in the down state. If not, the command will fail with the appropriate error code. The SCSI parameters for a given SCSI controller must first be set (from the firmware BCH prompt or using the option) before the parameters can be retrieved using the option. The command is allowed on Itanium(R)-based platforms for compatibility. No action is taken for the command. Options recognizes the following command-line options: Deletes an entry for the specified SCSI controller at dev_path from the SCSI table. Gets the SCSI parameters for the specified SCSI controller at dev_path. Sets the SCSI parameters for the specified SCSI controller at dev_path. Operands recognizes the following command-line operands: dev_path The device path of the SCSI controller. id The SCSI ID for the specified controller (defaults to 7). rate The SCSI rate for the specified controller. This parameter can have one of two values: for the corresponding fast wide and ultra wide SCSI interfaces. Note For managing SCSI controllers, use corresponding SCSI utilities. For further information refer to SECURITY RESTRICTIONS
This command is restricted to processes owned by superuser. When virtual partition flexible administrative capability is enabled, only a Designated-Admin vPar can set SCSI parameters for SCSI con- trollers. EXAMPLES
Set the SCSI ID for controller at 0/0/2/0 to 3 with the fast wide rate: RETURN VALUE
Successful. Invalid SCSI controller specification. Invalid SCSI ID. Could not communicate with virtual partition monitor. Virtual partition which owns SCSI controller is not in down state. Internal firmware call failed. Other error. AUTHOR
was developed by the Hewlett-Packard Company. SEE ALSO
vparadmin(1M), vparboot(1M), vparcreate(1M), vparconfig(1M), vpardump(1M), vparefiutil(1M), vparenv(1M), vparextract(1M), vparmodify(1M), vparreloc(1M), vparremove(1M), vparreset(1M), vparstatus(1M), vparresources(5), vpartition(5), vpmon(5). vparutil(1M)
All times are GMT -4. The time now is 08:20 PM.
Unix & Linux Forums Content Copyright 1993-2022. All Rights Reserved.
Privacy Policy