04-20-2011
the "host" is just a name which has access to a LUN. it can be any name...
5 More Discussions You Might Find Interesting
1. Filesystems, Disks and Memory
Hi,
We have 12x1TB SATA disks in our array and I need to create 10TB volume. I defined new storage profile on array and when I tried to add volume, I faced with ~2TB limit for new volumes. I didn't find how to set another limit on my storage profile. Is there is a way to configure one large... (3 Replies)
Discussion started by: Sapfeer
3 Replies
2. Solaris
Hello,
Wondering if anyone can help me with mounting a file share from my Sun T2000 server running Solaris 10 to my connected 2530 disk array?
I believe I've connected the disk array correctly and I have created a volume on the array using the filesystem (Sun_SAM-FS, RAID-5).
The T2000... (15 Replies)
Discussion started by: DundeeDancer
15 Replies
3. Solaris
Hi!
I have Sun StorageTek 2540 FC array and CAM works very slowly - I can wait for software response even more than 2 minutes... I run this software on Windows machine with Firefox Web Browser but speed is terrible... How can I make it works at least a little bit faster?.. (2 Replies)
Discussion started by: Sapfeer
2 Replies
4. Filesystems, Disks and Memory
In Sun manuals, I didn't find how to backup Sun StorageTek Common Array Manager's configuration. Is there a way to do it like backing up Brocade switch configuration? CAM is under Solaris 10.
Thank you in advance! (0 Replies)
Discussion started by: aixlover
0 Replies
5. Solaris
Bought a Sun StorageTek 2540 SAN array a few years ago from a company that was going out of business. When we first set it up, we were able to get all the software (Common Array Manager) and firmware directly from Sun.
We just upgraded the drives, but the array is too large for the firmware. Now... (6 Replies)
Discussion started by: edison303
6 Replies
SG_RDAC(8) SG3_UTILS SG_RDAC(8)
NAME
sg_rdac - Display or Modify RDAC Redundant Controller Page
SYNOPSIS
sg_rdac [-a] [-f=LUN] [-v] [-V] DEVICE
DESCRIPTION
sg_rdac displays or modifies the RDAC controller settings via the Redundant Controller Page (0x2C). When modifying the settings it allows
to transfer the ownership of individual drives to the controller the command was received on.
OPTIONS
-a Transfer all (visible) devices
-f=LUN Transfer the device identified by LUN. This command will only work if the controller supports 'Dual Active Mode' (aka active/active
mode).
-v be verbose
-V print version string then exit
EXIT STATUS
The exit status of sg_rdac is 0 when it is successful. Otherwise see the sg3_utils(8) man page.
AUTHOR
Written by Hannes Reinecke <hare at suse dot com>, based on sg_emc_trespass.
REPORTING BUGS
Report bugs to <dgilbert at interlog dot com>.
COPYRIGHT
Copyright (C) 2006-2007 Hannes Reinecke, Douglas Gilbert.
This software is distributed under the GPL version 2. There is NO warranty; not even for MERCHANTABILITY or FITNESS FOR A PARTICULAR PUR-
POSE.
sg3_utils-1.23 January 2007 SG_RDAC(8)