I'm trying to get the uptime of my computer (Mac OS X) and I can go into the terminal and type "uptime" OK, and that gives me a string with the uptime in it. The problem is that the string changes a lot, and its very difficult to get the data I'm trying to extract out cleanly.
Now I have 3... (2 Replies)
Hi there,
do someone have detailed information how to interpret the uptime command or rather which values can be called normal?
(i know what the information means, but i have no idea if these values are ok or to high:
3:02pm an 13:53, 2 Benutzer, Durchschnittslast: 10,06, 12,05, 13,00)
... (5 Replies)
Hi all,:o
i am new to shell scripting and i have aproblem like i just want to extractthe uptime of the system from an uptime command which gives the output as the Current time , how long the system has been running,how many users are surrently logged on and the system load averages for past 1,5,... (5 Replies)
Hi,
After run ps , uptime , w command I get reply "killed" as normal dba and staff group user.
As root every command works fine.
I cheched all the user settings , right with other servers and I could not find any error and other settings.
The oslevel is 5300-10-01-0921.
Any idea to... (12 Replies)
hello, i send the uptime command in the AIX and the days that is UP 14652 days this is around 40 years, today is with the correct date&time, hos can I reset the counter days? somebody can help me? regards (3 Replies)
Hi,
Can someone explain in detail what 'uptime' ,'last reboot' and 'who -b' commands do in solaris.
this commands are not executing in every solaris box. why this is happening. Has solaris got some inbuilt commands into it. If yes then where i have found them?
Thanks,Soubhik (6 Replies)
Hello Everyone,
One of our servers is showing a strange issue, let me paste the output
root # uptime
4:37pm 3 users, load average: 0.00, 0.04, 0.04
Its been running since months but you can see after time there isn't any output like up 191 days(s).
Even the who command with b... (1 Reply)
Hello folks,
uptime command not shows how long the system has been up.
I know it come from a corruption of /var/adm/utmpx file.
I've done :
cat /dev/null > /var/adm/utmpx
Now who and last commands work fine. But uptime still give me back an answer without the "up time".
In which... (6 Replies)
What is the uptime command output when the server is running more than one year?
My doubt is whether it show in number of days format or number years and number of days format?
For example, Assume the server is running 400 days 3 hrs 3 min 3 secs. The output like 400 days 3:3 min or 1 year 5... (3 Replies)
Discussion started by: maruthu
3 Replies
LEARN ABOUT SUSE
irsend
IRSEND(1) FSF IRSEND(1)NAME
irsend - basic LIRC program to send infra-red commands
SYNOPSIS
irsend [options] DIRECTIVE REMOTE CODE [CODE...]
DESCRIPTION
Asks the lircd daemon to send one or more CIR (Consumer Infra-Red) commands. This is intended for remote control of electronic devices such
as TV boxes, HiFi sets, etc.
DIRECTIVE can be:
SEND_ONCE - send CODE [CODE ...] once
SEND_START - start repeating CODE
SEND_STOP - stop repeating CODE
LIST - list configured remote items
SET_TRANSMITTERS - set transmitters NUM [NUM ...]
SIMULATE - simulate IR event
REMOTE is the name of a remote, as described in the lircd configuration file.
CODE is the name of a remote control key of REMOTE, as it appears in the lircd configuration file.
NUM is the transmitter number of the hardware device.
For the LIST DIRECTIVE, REMOTE and/or CODE can be empty:
LIST "" "" - list all configured remote names
LIST REMOTE "" - list all codes of REMOTE
LIST REMOTE CODE - list only CODE of REMOTE
The SIMULATE command only works if it has been explicitly enabled in lircd.
-h --help
display usage summary
-v --version
display version
-d --device
use given lircd socket [/var/run/lirc/lircd]
-a --address=host[:port]
connect to lircd at this address
-# --count=n
send command n times
EXAMPLES
irsend LIST DenonTuner ""
irsend SEND_ONCE DenonTuner PROG-SCAN
irsend SEND_ONCE OnkyoAmpli VOL-UP VOL-UP VOL-UP VOL-UP
irsend SEND_START OnkyoAmpli VOL-DOWN ; sleep 3
irsend SEND_STOP OnkyoAmpli VOL-DOWN
irsend SET_TRANSMITTERS 1
irsend SET_TRANSMITTERS 1 3 4
irsend SIMULATE "0000000000000476 00 OK TECHNISAT_ST3004S"
FILES
/etc/lirc/lircd.conf
Default lircd configuration file. It should contain all the remotes, their infra-red codes and the corresponding timing and wave-
form details.
DIAGNOSTICS
If lircd is not running (or /var/run/lirc/lircd lacks write permissions) irsend aborts with the following diagnostics:
"irsend: could not connect to socket"
"irsend: Connection refused" (or "Permission denied").
SEE ALSO
The documentation for lirc is maintained as html pages. They are located under html/ in the documentation directory.
lircd(8), mode2(1), smode2(1), xmode2(1), irrecord(1), irw(1), http://www.lirc.org.
irsend 0.8.7pre1 May 2010 IRSEND(1)