04-05-2011
use
newfs /dev/rdsk/c0t2d0sx
where x = 0 or 1 or 2 or 3 or 4 or 5 or 6
you need to run format. select the new disk. setup the slice sizes and then run newfs against the slice(s) that you have created.
8 More Discussions You Might Find Interesting
1. UNIX for Dummies Questions & Answers
I need help in the form of the complete procedures necessary in setting up an Apache web server on a Sun Sparc running Solaris 8
David Johnston
P.S New to the Unix arena (1 Reply)
Discussion started by: David Johnston
1 Replies
2. Solaris
A sparc server has a new SCSI hard disk added and labeled by the engineer, but they need to be formatted identically to an existing disk (c4t0d0). You decide to script the process and run from the command line without interaction.
I know that the following command line must be achieve this.
#... (3 Replies)
Discussion started by: kingsan
3 Replies
3. Solaris
Hello,
Running a Sun Solaris 9 E250 and need advice or suggestions on what type of external hard disks are compatible and or available. It's an old machine and is due for replacement soon but in the short term need an external hard drive for backup etc as the partner/backup machine has just... (2 Replies)
Discussion started by: KenLynch
2 Replies
4. Filesystems, Disks and Memory
Folks;
I just added 2 physical new hard drives to my SUSE server. My server is already running SUSE 10.3 version.
Is there a command i can use to add the new space or even see if the system can sees them? (3 Replies)
Discussion started by: Katkota
3 Replies
5. Solaris
Hi all,
I have application running on sun server T5440 4x8x1.4 GHz, 64 GB RAM, application running very slow though load average too low. when I install my application on another server SUN M3000 (One CPU 1x8x2.5GHz, 8GB RAM), application run smoothly.
Here is my server T5440 info:
... (6 Replies)
Discussion started by: insatiable1610
6 Replies
6. Solaris
show /HOST command shows that
status = OpenBoot Running
when in this state, can the power be unplugged from the server ?
we are unable to bring the status to "powered off". Even if we issue "stop /SYS" it will momentarily be in the powered off status and then go back to power on... (1 Reply)
Discussion started by: paulk93
1 Replies
7. Solaris
SPARC Enterprise T5440 Server, can not power off
I connect to Service Processor via serial port and submit the following to boot the system, it boots fine but can not power off the system. Can someone help?
The following takes me to unix login
-> start /SYS
-> start /SP/console... (6 Replies)
Discussion started by: paulk93
6 Replies
8. Solaris
Hi,
I have two SCSI Hard Drives in a Sun Solaris 8 server as shown below. I would like to access Disk1 and look at its contents, directory structure and files. How do I change my default directory from Disk 0 to Disk 1 and vice versa?
Thank you. (5 Replies)
Discussion started by: ssabet
5 Replies
LEARN ABOUT SUSE
ocf_pacemaker_healthsmart
OCF_PACEMAKER_HEALTH(7) Pacemaker Configuration OCF_PACEMAKER_HEALTH(7)
NAME
ocf_pacemaker_HealthSMART - SMART health status
SYNOPSIS
OCF_RESKEY_state=string OCF_RESKEY_drives=string OCF_RESKEY_temp_lower_limit=string OCF_RESKEY_temp_upper_limit=string
HealthSMART [start | stop | monitor | meta-data | validate-all]
DESCRIPTION
Systhem health agent that checks the S.M.A.R.T. status of the given drives and updates the #health-smart attribute.
SUPPORTED PARAMETERS
OCF_RESKEY_state = string [/var/run//health-smart-{OCF_RESOURCE_INSTANCE}.state]
State file
Location to store the resource state in.
OCF_RESKEY_drives = string [sda]
Drives to check
The drives to check as a SPACE separated list. Enter only the part after the "/dev/" i.e. "sda". At the moment /dev/sda is hard coded.
Sorry.
OCF_RESKEY_temp_lower_limit = string [0]
Lower limit for the temperature of the drive(s)
Lower limit of the temperature in deg C of the drive(s). Below this limit there status will be red. The yellow limit is 5 deg C more
than this value.
OCF_RESKEY_temp_upper_limit = string [60]
Upper limit for red smart attribute
Upper limit of the temperature if deg C of the drives(s). If the drive reports a temperature higher than this value the status of
#health-smart will be red. The yellow limit is 5 deg C below this value.
AUTHOR
Andrew Beekhof <andrew@beekhof.net>
Author.
Pacemaker Configuration 07/05/2010 OCF_PACEMAKER_HEALTH(7)