Sponsored Content
Operating Systems Solaris Adding new hard drives on Sun SPARC T5440 server with Solaris 10 Post 302511015 by ramatnmcc on Tuesday 5th of April 2011 01:44:40 PM
Old 04-05-2011
Thanks for a quick response. I am able to see the new hard disks when I do echo | format.

But when I use the newfs /dev/rdsk/c0t2d0

I get an error - No such file or Directory.

Am I doing some thing wrong here?
 

8 More Discussions You Might Find Interesting

1. UNIX for Dummies Questions & Answers

Info Needed in Seting up An apache Web Server on A Sun Sparc with Solaris 8

I need help in the form of the complete procedures necessary in setting up an Apache web server on a Sun Sparc running Solaris 8 David Johnston P.S New to the Unix arena (1 Reply)
Discussion started by: David Johnston
1 Replies

2. Solaris

Add new hard disk to sun sparc server?

A sparc server has a new SCSI hard disk added and labeled by the engineer, but they need to be formatted identically to an existing disk (c4t0d0). You decide to script the process and run from the command line without interaction. I know that the following command line must be achieve this. #... (3 Replies)
Discussion started by: kingsan
3 Replies

3. Solaris

Sun Solaris 9 E250 -- Suggestions For External Hard Drives

Hello, Running a Sun Solaris 9 E250 and need advice or suggestions on what type of external hard disks are compatible and or available. It's an old machine and is due for replacement soon but in the short term need an external hard drive for backup etc as the partner/backup machine has just... (2 Replies)
Discussion started by: KenLynch
2 Replies

4. Filesystems, Disks and Memory

Help adding new hard drives

Folks; I just added 2 physical new hard drives to my SUSE server. My server is already running SUSE 10.3 version. Is there a command i can use to add the new space or even see if the system can sees them? (3 Replies)
Discussion started by: Katkota
3 Replies

5. Solaris

Application running too slow on Sun SPARC T5440 but run normal on sun M3000

Hi all, I have application running on sun server T5440 4x8x1.4 GHz, 64 GB RAM, application running very slow though load average too low. when I install my application on another server SUN M3000 (One CPU 1x8x2.5GHz, 8GB RAM), application run smoothly. Here is my server T5440 info: ... (6 Replies)
Discussion started by: insatiable1610
6 Replies

6. Solaris

Unplug power from Sparc Server T5440 when in OpenBoot

show /HOST command shows that status = OpenBoot Running when in this state, can the power be unplugged from the server ? we are unable to bring the status to "powered off". Even if we issue "stop /SYS" it will momentarily be in the powered off status and then go back to power on... (1 Reply)
Discussion started by: paulk93
1 Replies

7. Solaris

SPARC Enterprise T5440 Server, can not power off

SPARC Enterprise T5440 Server, can not power off I connect to Service Processor via serial port and submit the following to boot the system, it boots fine but can not power off the system. Can someone help? The following takes me to unix login -> start /SYS -> start /SP/console... (6 Replies)
Discussion started by: paulk93
6 Replies

8. Solaris

Solaris 8 - Accessing Hard Drives

Hi, I have two SCSI Hard Drives in a Sun Solaris 8 server as shown below. I would like to access Disk1 and look at its contents, directory structure and files. How do I change my default directory from Disk 0 to Disk 1 and vice versa? Thank you. (5 Replies)
Discussion started by: ssabet
5 Replies
MLXCONTROL(8)						    BSD System Manager's Manual 					     MLXCONTROL(8)

NAME
mlxcontrol -- Mylex DAC-family RAID management utility SYNOPSIS
mlxcontrol <command> [args] mlxcontrol status [-qv] [drive] mlxcontrol rescan controller [controller ...] mlxcontrol detach drive [drive ...] mlxcontrol detach -a mlxcontrol check drive mlxcontrol config controller mlxcontrol help command DESCRIPTION
The mlxcontrol utility provides status monitoring and management functions for devices attached to the mlx(4) driver. Controller names are of the form "mlxN" where N is the unit number of the controller. Drive names are of the form "mlxdN" where N is the unit number of the drive. Do not specify the path to a device node. status Print the status of controllers and system drives. If one or more drives are specified, only print information about these drives, otherwise print information about all controllers and drives in the system. With the -v flag, display much more verbose informa- tion. With the -q flag, do not print any output. This command returns 0 if all drives tested are online, 1 if one or more drives are critical and 2 if one or more are offline. rescan Rescan one or more controllers for non-attached system drives (e.g. drives that have been detached or created subsequent to driver initialisation). If the -a flag is supplied, rescan all controllers in the system. detach Detach one or more system drives. Drives must be unmounted and not opened by any other utility for this command to succeed. If the -a flag is supplied, detach all system drives from the nominated controller. check Initiate a consistency check and repair pass on a redundant system drive (e.g. RAID1 or RAID5). The controller will scan the system drive and repair any inconsistencies. This command returns immediately; use the status command to monitor the progress of the check. rebuild Requires two arguments, controller and physdrive as specified in the output of the status command. All system drives using space on the physical drive physdrive are rebuilt, reconstructing all data on the drive. Note that each controller can only perform one rebuild at a time. This command returns immediately; use the status command to monitor the progress of the rebuild. config Print the current configuration from the nominated controller. This command will be updated to allow addition/deletion of system drives from a configuration in a future release. help Print usage information for command. AUTHORS
The mlxcontrol utility was written by Michael Smith <msmith@FreeBSD.org>. BUGS
The config command does not yet support modifying system drive configuration. Error log extraction is not yet supported. BSD
April 10, 2000 BSD
All times are GMT -4. The time now is 07:25 AM.
Unix & Linux Forums Content Copyright 1993-2022. All Rights Reserved.