Sponsored Content
Operating Systems Solaris Adding new hard drives on Sun SPARC T5440 server with Solaris 10 Post 302510994 by solaris_user on Tuesday 5th of April 2011 12:46:09 PM
Old 04-05-2011
look for a new hardisk
Code:
su -
echo | format

then create new UFS on target HDD

Code:
newfs /dev/rdsk/xxxxxx

then add new disk to your /etc/fstab file to automatically mount at boot
 

8 More Discussions You Might Find Interesting

1. UNIX for Dummies Questions & Answers

Info Needed in Seting up An apache Web Server on A Sun Sparc with Solaris 8

I need help in the form of the complete procedures necessary in setting up an Apache web server on a Sun Sparc running Solaris 8 David Johnston P.S New to the Unix arena (1 Reply)
Discussion started by: David Johnston
1 Replies

2. Solaris

Add new hard disk to sun sparc server?

A sparc server has a new SCSI hard disk added and labeled by the engineer, but they need to be formatted identically to an existing disk (c4t0d0). You decide to script the process and run from the command line without interaction. I know that the following command line must be achieve this. #... (3 Replies)
Discussion started by: kingsan
3 Replies

3. Solaris

Sun Solaris 9 E250 -- Suggestions For External Hard Drives

Hello, Running a Sun Solaris 9 E250 and need advice or suggestions on what type of external hard disks are compatible and or available. It's an old machine and is due for replacement soon but in the short term need an external hard drive for backup etc as the partner/backup machine has just... (2 Replies)
Discussion started by: KenLynch
2 Replies

4. Filesystems, Disks and Memory

Help adding new hard drives

Folks; I just added 2 physical new hard drives to my SUSE server. My server is already running SUSE 10.3 version. Is there a command i can use to add the new space or even see if the system can sees them? (3 Replies)
Discussion started by: Katkota
3 Replies

5. Solaris

Application running too slow on Sun SPARC T5440 but run normal on sun M3000

Hi all, I have application running on sun server T5440 4x8x1.4 GHz, 64 GB RAM, application running very slow though load average too low. when I install my application on another server SUN M3000 (One CPU 1x8x2.5GHz, 8GB RAM), application run smoothly. Here is my server T5440 info: ... (6 Replies)
Discussion started by: insatiable1610
6 Replies

6. Solaris

Unplug power from Sparc Server T5440 when in OpenBoot

show /HOST command shows that status = OpenBoot Running when in this state, can the power be unplugged from the server ? we are unable to bring the status to "powered off". Even if we issue "stop /SYS" it will momentarily be in the powered off status and then go back to power on... (1 Reply)
Discussion started by: paulk93
1 Replies

7. Solaris

SPARC Enterprise T5440 Server, can not power off

SPARC Enterprise T5440 Server, can not power off I connect to Service Processor via serial port and submit the following to boot the system, it boots fine but can not power off the system. Can someone help? The following takes me to unix login -> start /SYS -> start /SP/console... (6 Replies)
Discussion started by: paulk93
6 Replies

8. Solaris

Solaris 8 - Accessing Hard Drives

Hi, I have two SCSI Hard Drives in a Sun Solaris 8 server as shown below. I would like to access Disk1 and look at its contents, directory structure and files. How do I change my default directory from Disk 0 to Disk 1 and vice versa? Thank you. (5 Replies)
Discussion started by: ssabet
5 Replies
IDA(4)							   BSD Kernel Interfaces Manual 						    IDA(4)

NAME
ida -- Compaq Intelligent Drive Array Controllers SYNOPSIS
To compile this driver into the kernel, place the following lines in your kernel configuration file: device scbus device ida Alternatively, to load the driver as a module at boot time, place the following line in loader.conf(5): ida_load="YES" DESCRIPTION
The Compaq Intelligent Drive Array (IDA) technology is used to distribute data across an array of hard drives. It unites these hard drives into one or more high-performance logical drives. The drive array is managed by an array controller. These controllers have the ability to provide fault tolerance for the connected drives and optionally provide write cache for the logical drives. It is also possible for an application to access the SCSI bus subsystem directly by using the pass-through interface. HARDWARE
The following controllers are supported by the ida driver: o Compaq SMART Array 221 o Compaq Integrated SMART Array Controller o Compaq SMART Array 4200 o Compaq SMART Array 4250ES o Compaq SMART 3200 Controller o Compaq SMART 3100ES Controller o Compaq SMART-2/DH Controller o Compaq SMART-2/SL Controller o Compaq SMART-2/P Controller o Compaq SMART-2/E Controller o Compaq SMART Controller IMPLEMENTATION NOTES
Extreme caution should be exercised when using the pass-through interface. It is possible to interfere with normal system I/O and cause hangs if pass-through is used to an active device. Pass-through should only be used to a device that is otherwise quiescent. SEE ALSO
cam(4), pass(4), xpt(4), camcontrol(8) AUTHORS
The ida driver was written by Jonathan Lemon <jlemon@FreeBSD.org> and Matthew N. Dodd <mdodd@FreeBSD.org>. This manual page was written by Tom Rhodes <trhodes@FreeBSD.org>. BSD
August 8, 2004 BSD
All times are GMT -4. The time now is 08:44 AM.
Unix & Linux Forums Content Copyright 1993-2022. All Rights Reserved.
Privacy Policy