LPAR freezes after switching of storage (lpar is mirrored)

Hi all,

I have the following configuration

2 ds3524 storage disk systems located over 2 locations
2 P720 server located over 2 locations

DS3524 are connected to san switch.
Each vio server has 1 fc adapter attached to a san switch.

per p720 server 2 virtual io servers. Vio 1 has 1 lun from 1 ds3524, Vio 2 has 1 lun from the other ds3524
On the lpar we use LVM mirroring.

The problem:

When we halt 1 DS3524 the lpar freezes for about 30 seconds and then is again available.
Is this normal behaviour? When i shutdown 1 vio server , everything on the lpar is ok , no freeze.

Any ideas ?

thx MarkieMark
 

10 More Discussions You Might Find Interesting

1. AIX

LPAR and CFGMGR

I have a P570 that for some reason is not allowing the P1-T6 NIC to be recognized. I have confirmed from the HMC that it is set for the LPAR, but when I do a cfgmgr, it won't recognize it. It though is recognizing the slot cards just fine which are P1-C3 for one shelf and P1-C3 of another shelf.... (1 Reply)
Discussion started by: LegendMan
1 Replies

2. AIX

Autostart of LPAR

Hi, I have 2 lpars on my AIX that needs to be started manually after each reboot. Because the servers are storing the NFS and NIS info, other servers won't run correctly until they start up. I found in IBM documentation the steps to make it automatic. My question is, I want to know if... (2 Replies)
Discussion started by: rahzzbietel
2 Replies

3. AIX

VIO SAN STORAGE LPAR ( Dynamically increasing size )

Hi, Is there a way to dynamically increase the size of virtual disk on the LPAR. The virtual disk is coming from my VIO Server. From my SAN I have allocated a disk to VIO Server and from VIO Server to my LPAR....If I increase the space of the logical SAN DISK (DS 4700 using IBM TotalStorage... (0 Replies)
Discussion started by: filosophizer
0 Replies

4. AIX

LPAR

I am planning for System P with 2 number of 2-core processor (4 core in total). Can I make 3 LPARS with this processor configuration without the support of micropartitioning, that means with simple LPAR only. (3 Replies)
Discussion started by: pchangba
3 Replies

5. AIX

ldom and lpar

hi, Plz let me know if the concept of sun ldom and aix lpar is same or not. thnx, snj (1 Reply)
Discussion started by: snjksh
1 Replies

6. AIX

LPAR creation

can i get a step b syep explanation in creating LPAR... i have searched for tutorials i couldn't find the right one.... (2 Replies)
Discussion started by: udtyuvaraj
2 Replies

7. AIX

Bootting up a new LPAR

I have created a new LPAR using IVM. I activated the LPAR, and start the window terminal (java), it prompt me for the padmin password. After keyin the password, it will shows BOOTP parameter. I am just wondering how come it didnt go to screen where i can select to go into SMS menu to pick... (0 Replies)
Discussion started by: wingcross
0 Replies

8. AIX

Mirroring in LPAR

Hi Folks, I am a newbie in AIX. Can someone please tell me how to do root mirroring in AIX LPAR which is created from mksysb image via HMC/NIM. ? AIX 5.3/6.1 Let me know. Thanks in advance (2 Replies)
Discussion started by: snchaudhari2
2 Replies

9. AIX

Hostname for each lpar

Hi Gurus, Can a AIX server with 4 LPARs, each having it's own hostname on the same physical host. Is this possible? Thanks, S (2 Replies)
Discussion started by: svajhala
2 Replies

10. AIX

How to differentiate between a standalone LPAR and a VIOC (which again is a lpar)?

There can be configurations in IBM Server wherein a standalone partition is created on some supported IBM Server Or A VIOS - VIOC LPARs created. Now in both cases they are lpars. But if I want to differentiate b/w a standalone LPAR vs an VIOC LPAR how can I do..? On a... (2 Replies)
Discussion started by: Manish00712
2 Replies
HALT(8) 						Linux System Administrator's Manual						   HALT(8)

NAME
halt, reboot, poweroff - stop the system. SYNOPSIS
/sbin/halt [-n] [-w] [-d] [-f] [-i] [-p] [-h] /sbin/reboot [-n] [-w] [-d] [-f] [-i] /sbin/poweroff [-n] [-w] [-d] [-f] [-i] [-h] DESCRIPTION
Halt notes that the system is being brought down in the file /var/log/wtmp, and then either tells the kernel to halt, reboot or poweroff the system. If halt or reboot is called when the system is not in runlevel 0 or 6, in other words when it's running normally, shutdown will be invoked instead (with the -h or -r flag). For more info see the shutdown(8) manpage. The rest of this manpage describes the behaviour in runlevels 0 and 6, that is when the systems shutdown scripts are being run. OPTIONS
-n Don't sync before reboot or halt. -w Don't actually reboot or halt but only write the wtmp record (in the /var/log/wtmp file). -d Don't write the wtmp record. The -n flag implies -d. -f Force halt or reboot, don't call shutdown(8). -i Shut down all network interfaces just before halt or reboot. -h Put all harddrives on the system in standby mode just before halt or poweroff. -p When halting the system, do a poweroff. This is the default when halt is called as poweroff. DIAGNOSTICS
If you're not the superuser, you will get the message `must be superuser'. NOTES
Under older sysvinit releases , reboot and halt should never be called directly. From release 2.74 on halt and reboot invoke shutdown(8) if the system is not in runlevel 0 or 6. This means that if halt or reboot cannot find out the current runlevel (for example, when /var/run/utmp hasn't been initialized correctly) shutdown will be called, which might not be what you want. Use the -f flag if you want to do a hard halt or reboot. The -h flag puts all harddisks in standby mode just before halt or poweroff. Right now this is only implemented for IDE drives. A side effect of putting the drive in standby mode is that the write cache on the disk is flushed. This is important for IDE drives, since the kernel doesn't flush the write-cache itself before poweroff. The halt program uses /proc/ide/hd* to find all IDE disk devices, which means that /proc needs to be mounted when halt or poweroff is called or the -h switch will do nothing. AUTHOR
Miquel van Smoorenburg, miquels@cistron.nl SEE ALSO
shutdown(8), init(8) Nov 6, 2001 HALT(8)
All times are GMT -4. The time now is 07:13 PM.
Unix & Linux Forums Content Copyright 1993-2022. All Rights Reserved.
Privacy Policy