02-25-2011
You never stated what command you are trying to run.
There appears to be limited choices in the XSCF for the fmadm command.
fujitsu.com/downloads/SPARCE/manuals/sparc-commone/mx-xscfref-en-03.pdf
it states that " You must have platop, platadm, or fieldeng privileges to run this command. "
10 More Discussions You Might Find Interesting
1. Solaris
Hi Guys,
Anyone know any commands to verify the graphics card is installed correctly on an M4000?
show-displays just comes back and echoes nothing.
Also there is on input-device or output-device variable when you run printenv.
This in itself is worrying.
Any advice would be... (4 Replies)
Discussion started by: callmebob
4 Replies
2. UNIX for Dummies Questions & Answers
I'm trying to power on our SUN m4000 server after a recent shutdown. When I try to connect to the xscf console I'm getting prompted for a password. The system is not asking for a login just a password. Below is the output from the xscf console.
Anyone know how I can safely get back to the... (0 Replies)
Discussion started by: orahi001
0 Replies
3. Solaris
Hi everyone,
I wanted to ask a question about fmadm and explorer outputs.
Recently found out that an error shows up in fmadm saying "mb is faulty but still in service" so we took an explorer send to Oracle Support. Error led wasn't on but we didn't want to risk the probability.
They came up... (1 Reply)
Discussion started by: royalliege
1 Replies
4. Solaris
Hi Guys and Gals,
Can someone help me possible?
Trying to power up an M4000 and it comes up with xscf fault (reason=0) it then just hangs there.
Any help would be gratefully appreciated.
Thanks
Martin (4 Replies)
Discussion started by: callmebob
4 Replies
5. Solaris
Hii All
I was building two M4000 servers and one was successfully installed.
Other one /usr has been unmounted. my putty session got disconnected and i connected to console where it asked for root single maintence
#
# init 0
not foung
# df -h
not found
#
xscf>poweroff -a
xscf>... (8 Replies)
Discussion started by: seems
8 Replies
6. Solaris
Dear Team,
This time i am facing some problems in Sun SPARC M4000 server. I have a doubt, when we are upgrading the firmware if XSCF , the OBP is also upgraded.
What about server OBP, Is that upgardation need to be done separately ?
what about DVD-ROM, HARD DISK firmware.... (3 Replies)
Discussion started by: sudhansu
3 Replies
7. Solaris
Hi Guys and Gals,
Does anyone know how to track down a faulty DIMM on the memory board of an M4000?
showhardconf tells me which board it is, but was wondering if there was a way to track it down to a DIMM?
Thanks in advance
Martin (5 Replies)
Discussion started by: callmebob
5 Replies
8. Solaris
Hello,
I'm set to go out to our M4000 to reset the XSCF password, since the person who set it up doesn't remember what password they setup.
I have all the steps, but the only question I can't find an answer to is around the mode switch. Right now, based on prtdiag, the mode switch is in... (2 Replies)
Discussion started by: QuickNull
2 Replies
9. Solaris
Hi Gurus
Can someone help me in explaining the below outputs .
psrinfo -p
4
/usr/sbin/psrinfo -pv
The physical processor has 4 virtual processors (0-3)
SPARC64-VI (portid 1024 impl 0x6 ver 0x93 clock 2150 MHz)
The physical processor has 4 virtual processors (8-11)
SPARC64-VI... (3 Replies)
Discussion started by: ningy
3 Replies
10. Solaris
Hi All,
I have an Oracle M4000 server with Solaris 10 OS. I have access to Solaris root prompt.
But I don't know the XSCF IP of this server.
Is there any way to display XSCF IP from Solaris OS? (2 Replies)
Discussion started by: byrusber
2 Replies
itruns(8) System Manager's Manual itruns(8)
NAME
itruns - set up files for use by the it command
SYNOPSIS
/sbin/itruns file [file...] in run-state [, file [file...] in run-state] [,...]
DESCRIPTION
The itruns program sets up scripts to be run by it(8). (These programs are typically used within system configuration and installation
scripts.) The itruns command searches for /sbin/it.d/bin/file. If itruns finds the file, it creates one or more symbolic links from
/sbin/it.d/run-state.d/file to /sbin/it.d/bin/file.
The run-state argument can be a single run state, or it can be two run states separated by either the word or or the word and. If two run
states are specified with the or keyword, itruns checks for (and creates, if necessary) a directory whose name combines both run states and
places a link in that directory so that the file will be executed when the it program detects either state. You can collapse two or-sepa-
rated states into a single expression; for example, 2 or 3 can be expressed as 23. If the and keyword is used, itruns checks for (and cre-
ates, if necessary) two separate directories and places a link in each of them so that either state triggers execution of the file indepen-
dently of the other state.
If two or more files are specified for a single run-state argument, links are created for all of the files as indicated by the run-state
argument.
If two or more combinations of files and run states are specified as comma-separated expressions, itruns treats each combination individu-
ally.
RESTRICTIONS
The itruns command must be executed from the root directory (/). The command finds only files that are located in the /sbin/it.d/bin direc-
tory.
EXAMPLES
This example sets up the doconfig script to be run when the system is booted to run state 2: itruns doconfig in 2 Either of the command
lines in this example sets up the doconfig and getdate scripts to be run when the system is booted to run state 2 or to run state 3: itruns
doconfig getdate in 2 or 3 itruns doconfig getdate in 23 This example sets up the doconfig script to be run when the system is booted to
run state 2 and again when the system comes to run state 3, the getdate script to be run only in run state 2, and the getsysname script to
be run only in run state 3: itruns doconfig in 2 and 3, getdate in 2, getsysname in 3
SEE ALSO
Commands: it(8)
itruns(8)