Sponsored Content
Full Discussion: Storagetek 2540
Special Forums Hardware Storagetek 2540 Post 302498738 by acorradi on Tuesday 22nd of February 2011 10:16:40 AM
Old 02-22-2011
Storagetek 2540

Hello all !

I am a beginner about system and networking , and after some research on internet , i didn't find any relevant information , so i post here , if someone have an experience with this kind of material or if some documentation about how to connect my storage device on my server.

I can give some information :

Server : Sun Firex x4600 with RedHat Entreprise
Storage device : StorageTek 2540

I can ping the StorageTek 2540 ; i can see the space disk and some other informations ... from the Storage Common Array Manager , but i can't use the StorageTek 2540.

Thanks in advance

PS: I don't know if it is the good category to post it. I'm sorry

Last edited by acorradi; 02-23-2011 at 03:22 AM..
 

9 More Discussions You Might Find Interesting

1. Solaris

Sun Sparc T2000 + StorageTek 2540 - Help, I'm lost

I have a Sun Sparc T2000 (Solaris 10 05-08) and have installed a PCI-X 4GB Single Port HBA card in it. I have one StorageTek 2540 array that I would like to connect to the T2000. For the moment it would be a single path connection, but I've ordered a 2nd HBA, so eventually it would be... (4 Replies)
Discussion started by: soliberus
4 Replies

2. Solaris

One StorageTek 6140 vs Two (2) 2540 's?

We're moving our production 3510FC to development, so we need to replace the production 3510FC. The 6140 is nice, but pricey. Here's the question: Would two 2540's (RAID 10) be 'faster' than one 3510? (RAID 10) and faster than one 6140 (RAID 10)? One StoregeTek 6140 (16x72GB 15k rpm fc-al... (12 Replies)
Discussion started by: buddhavelvet
12 Replies

3. Filesystems, Disks and Memory

Configure large volume on Sun StorageTek 2540 array

Hi, We have 12x1TB SATA disks in our array and I need to create 10TB volume. I defined new storage profile on array and when I tried to add volume, I faced with ~2TB limit for new volumes. I didn't find how to set another limit on my storage profile. Is there is a way to configure one large... (3 Replies)
Discussion started by: Sapfeer
3 Replies

4. Solaris

Sun StorageTek 2540 - shutdown matrix

Hi, I have a simple question on how to correctly disable the matrix? Looking for the Common Array Manager and I do not see this option... Thank for help (3 Replies)
Discussion started by: bieszczaders
3 Replies

5. Solaris

Storagetek 2540

Hi peeps, Was wondering if anyone can help me, got a couple of storagetek 2540's that I need to configure. Trouble is I think they were brought as second user as all that came with them was cables. Does anyone know how to configure them (i.e. create raid sets and map to Luns and present... (1 Reply)
Discussion started by: callmebob
1 Replies

6. Hardware

StorageTek 2540 battery failed

Hi all, My Sun StorageTek 2540 have redundant batteries, but a battery was failed. # /opt/SUNWstkcam/bin/sscs list -d MyStorage1 fru Name FRU Alarm State Status Revision Unique Id -------------------------- ----------- --------... (2 Replies)
Discussion started by: buyantugs
2 Replies

7. Hardware

Storagetek 2540

Hi Guys and Gals, Wionder if you could help me, got a problem with a controller on a storagetek 2540, dead when fully powered up but if you reboot, it is ok for a couple of seconds (and you can ping it). Then once the array is fully up, it goes faulty and is un-pingable. Had anyone... (4 Replies)
Discussion started by: callmebob
4 Replies

8. Solaris

StorageTek 2540 SAN array

Bought a Sun StorageTek 2540 SAN array a few years ago from a company that was going out of business. When we first set it up, we were able to get all the software (Common Array Manager) and firmware directly from Sun. We just upgraded the drives, but the array is too large for the firmware. Now... (6 Replies)
Discussion started by: edison303
6 Replies

9. Solaris

Server M4000 server lost connectivity to storagetek 2540

Hi Guys, I have situation here ... server M4000 server lost connectivity to storagetek 2540 , storagetek 2540 unable to be ping.From DAS URL the storage is undetected. Any idea why this is happening. Please share. Thank you. Raj (1 Reply)
Discussion started by: muralirajah
1 Replies
i2o_bs(7D)							      Devices								i2o_bs(7D)

NAME
i2o_bs - Block Storage OSM for I2O SYNOPSIS
disk@local target id#:a through u disk@local target id#:a through u raw DESCRIPTION
The I2O Block Storage OSM abstraction (BSA, which also is referred to as block storage class) layer is the primary interface that Solaris operating environments use to access block storage devices. A block storage device provides random access to a permanent storage medium. The i2o_bs device driver uses I2O Block Storage class messages to control the block device; and provides the same functionality (ioctls, for example) that is present in the Solaris device driver like 'cmdk, dadk' on x86 for disk. The maximum size disk supported by i2o_bs is the same as what is available on x86. The i2o_bs is currently implemented version 1.5 of Intelligent IO specification. The block files access the disk using the system's normal buffering mechanism and are read and written without regard to physical disk records. There is also a "raw" interface that provides for direct transmission between the disk and the user's read or write buffer. A single read or write call usually results in one I/O operation; raw I/O is therefore considerably more efficient when many bytes are transmitted. The names of the block files are found in /dev/dsk; the names of the raw files are found in /dev/rdsk. I2O associates each block storage device with a unique ID called a local target id that is assigned by I2O hardware. This information can be acquired by the block storage OSM through I2O Block Storage class messages. For Block Storage OSM, nodes are created in /devices/pci#/pci# which include the local target ID as one component of device name that the node refers to. However the /dev names and the names in /dev/dsk and /dev/rdsk do not encode the local target id in any part of the name. For example, you might have the following: /devices/ /dev/dsk name --------------------------------------------------------------- /devices/pci@0,0/pci101e,0@10,1/disk@10:a /dev/dsk/c1d0s0 I/O requests to the disk must have an offset and transfer length that is a multiple of 512 bytes or the driver returns an EINVAL error. Slice 0 is normally used for the root file system on a disk, slice 1 is used as a paging area (for example, swap), and slice 2 for backing up the entire fdisk partition for Solaris software. Other slices may be used for usr file systems or system reserved area. Fdisk partition 0 is to access the entire disk and is generally used by the fdisk(1M) program. FILES
/dev/dsk/cndn[s|p]n block device /dev/rdsk/cndn[s|p]n raw device where: cn controller n dn instance number sn UNIX system slice n (0-15) pn fdisk partition(0) /kernel/drv/i2o_bs i2o_bs driver /kernel/drv/i2o_bs.conf Configuration file ATTRIBUTES
See attributes(5) for descriptions of the following attributes: +-----------------------------+-----------------------------+ |ATTRIBUTE TYPE |ATTRIBUTE VALUE +-----------------------------+-----------------------------+ |Architecture |x86 | +-----------------------------+-----------------------------+ SEE ALSO
fdisk(1M), format(1M)mount(1M),lseek(2), read(2), write(2), readdir(3C), vfstab(4), acct.h(3HEAD), attributes(5), dkio(7I) SunOS 5.10 21 Jul 1998 i2o_bs(7D)
All times are GMT -4. The time now is 01:13 PM.
Unix & Linux Forums Content Copyright 1993-2022. All Rights Reserved.
Privacy Policy