02-11-2011
Read man kill and man signals, some signals can be caught, ignored and others not.
If you get a signal when blocked, your process services it and then the blocked call errors out, errno=EINTR, which means try again immediately.
This User Gave Thanks to DGPickett For This Post:
10 More Discussions You Might Find Interesting
1. UNIX for Dummies Questions & Answers
What does the system call "dup" do?
What is the difference between dup and dup2
I have a fair idea of what it does but I am confused when its coming down to the exact details...
Please help me!:confused: (2 Replies)
Discussion started by: clickonline1
2 Replies
2. UNIX for Dummies Questions & Answers
Which system calls are made for operations cp and mv (2 Replies)
Discussion started by: gaurava99
2 Replies
3. UNIX for Dummies Questions & Answers
open, creat, read, write, lseek and close
Are they all primitive?
:confused:
*Another Question: is there a different between a system call, and an i/o system call? (2 Replies)
Discussion started by: PlunderBunny
2 Replies
4. Solaris
where can i find the differences in System calls between solaris and aix?
also is it possible to find a comprehensive list of them? (1 Reply)
Discussion started by: TECHRAMESH
1 Replies
5. IP Networking
Is there any facility to filter/identify the data calls and voice calls coming throug modem?
OR
Can we get the data or voice calls information through a script(preferably C Kermit)? (0 Replies)
Discussion started by: pcsaji
0 Replies
6. UNIX Desktop Questions & Answers
Hi,
I'm new to UNIX system calls. Can someone share your knowledge as to how exactly system calls should be executed?
Can they be typed like commands such as mkdir on the terminal itself? Also, are there any websites which will show me an example of the output to expect when a system call like... (1 Reply)
Discussion started by: ilavenil
1 Replies
7. BSD
what is the functions and relationship between fork,exec,wait system calls
as i am a beginer just want the fundamentals. (1 Reply)
Discussion started by: sangramdas
1 Replies
8. UNIX for Dummies Questions & Answers
Hi all,
I am new here .
I want to know about system call in detail.
As system calls are also function .How system identifies it.:) (2 Replies)
Discussion started by: vishwasrao
2 Replies
9. UNIX for Dummies Questions & Answers
I know how to add signal to a set. But what if I want to add 2 or 3 signals to the set.
I know I can use sigaddset (&set,SIGBUS)....but what if I want to add SIGBUS and SIGALRM at once. Do i have to do it like this..
sigaddset (&set,SIGBUS);
sigaddset (&set,SIGALRM);
Is there another way to... (0 Replies)
Discussion started by: joker40
0 Replies
10. UNIX for Advanced & Expert Users
What will happen if signal comes while a system call is being executed?
How it will be handled? (1 Reply)
Discussion started by: rupeshkp728
1 Replies
LEARN ABOUT BSD
siginterrupt
SIGINTERRUPT(3) Library Functions Manual SIGINTERRUPT(3)
NAME
siginterrupt - allow signals to interrupt system calls
SYNOPSIS
siginterrupt(sig, flag);
int sig, flag;
DESCRIPTION
Siginterrupt is used to change the system call restart behavior when a system call is interrupted by the specified signal. If the flag is
false (0), then system calls will be restarted if they are interrupted by the specified signal and no data has been transferred yet. Sys-
tem call restart is the default behavior on 4.2 BSD.
If the flag is true (1), then restarting of system calls is disabled. If a system call is interrupted by the specified signal and no data
has been transferred, the system call will return -1 with errno set to EINTR. Interrupted system calls that have started transferring data
will return the amount of data actually transferred. System call interrupt is the signal behavior found on 4.1 BSD and AT&T System V UNIX
systems.
Note that the new 4.2 BSD signal handling semantics are not altered in any other way. Most notably, signal handlers always remain
installed until explicitly changed by a subsequent sigvec(2) call, and the signal mask operates as documented in sigvec(2). Programs may
switch between restartable and interruptible system call operation as often as desired in the execution of a program.
Issuing a siginterrupt(3) call during the execution of a signal handler will cause the new action to take place on the next signal to be
caught.
NOTES
This library routine uses an extension of the sigvec(2) system call that is not available in 4.2BSD, hence it should not be used if back-
ward compatibility is needed.
RETURN VALUE
A 0 value indicates that the call succeeded. A -1 value indicates that an invalid signal number has been supplied.
SEE ALSO
sigvec(2), sigblock(2), sigpause(2), sigsetmask(2).
4.3 Berkeley Distribution May 15, 1985 SIGINTERRUPT(3)