Sponsored Content
Operating Systems Solaris Can't ping new PCI LAN card x4270_m2 Post 302495780 by DukeNuke2 on Friday 11th of February 2011 07:23:53 AM
Old 02-11-2011
try a "ifconfig aggr1 down" and after that, try again with the ping. you have two interfaces in the same net/subnet. so the ping might go out through the other interface.

aggr1 is btw a link aggregation which you can have a look at with "dladm show-aggr".
This User Gave Thanks to DukeNuke2 For This Post:
 

10 More Discussions You Might Find Interesting

1. Cybersecurity

lan card autonegotiation?

what is lan card autonegotiation ? how to enable and disable this feature? (2 Replies)
Discussion started by: nabil_boussetta
2 Replies

2. SCO

LAN card problem

Dear all Im facing one problem in SCO 5.0.5 , its that in the server there are three LAN cards INTEL PRO 100 series but when we configure all the three cards then LAN stops working . self ping is possible but no one can ping the server. If we remove driver of any one card LAN starts working. Is... (1 Reply)
Discussion started by: ccvyas
1 Replies

3. SuSE

HCF win modem PCI card

Hey all, ive got redhat 80 and trying to install a HCF win modem. Ive intsalled the drivers from linuxant.com using the rpm - i packagename.rpm command, but i still cant use the modem any suggestions ? (3 Replies)
Discussion started by: kiwi_bloke
3 Replies

4. Solaris

rs232 pci-card

hello mates, do you know a manufactor for rs232 serial pci cards for the sparc architecture? it seems that there is no original product from sun for that purpose. strange, isn't it? problem is that i have a V250 with only one db9 rs232 serial port, and i need it for a modem connection, but i also... (1 Reply)
Discussion started by: pressy
1 Replies

5. Solaris

Does x86 solaris 9 support PCI RealTek Lan Card

Hi, i have a RealTek Lan Card on my machine. Does Solaris 9 supports this lan card . Thank You, Shafi (3 Replies)
Discussion started by: sol8admin
3 Replies

6. AIX

Add PCI ethernet card?

Hi everyone, I recently inherited an IBM RS/6000 43P 150, and it appears that the on board ethernet is dead. Can I put in a PCI ethernet card and use that as the default ethernet connection (as opposed to the one on the motherboard)? If so, what type of card can I use and how does one configure... (2 Replies)
Discussion started by: Jwoollard
2 Replies

7. UNIX for Dummies Questions & Answers

disable power management to a PCI card

I have a US Robotics USR5416 wireless networking card and everytime after hours of inactivity the cardseems to shutdown. I read somewhere the it does not support power management. Is there a way to disable power management to that particular PCI card? (0 Replies)
Discussion started by: diesel440
0 Replies

8. Linux

PCI Card recognized

I installed PCI Card HP SC44Ge - SAS1068E on my linux CentOS 5.4 is there a way to find out if the PCI is properly installed and recognized by linux. lspci is enough? just to add that PCI card is connected to a tape... also how can I find out driver and firmware version? thanks a... (1 Reply)
Discussion started by: karlochacon
1 Replies

9. Solaris

Q:x4270_m2 reconfigure PCI card to slot 5?

Hello all, I have a problem with my x4270_m2 server. I have a GBE lan built into the back of my server and I have a QGE pci card in slot 2 to be used as a redundant. My server is not picking up the QGE lan card in slot2. From investigation of the /etc/path_to_inst, which shows: #grep e1000... (2 Replies)
Discussion started by: kerrygold
2 Replies

10. AIX

AIX -How to find which NIC is on which PCI card

Hi All, How can I find out which is ETH5 on my AIX P5 system. I have about seven different NIC card on this. I did move the cable to each one but still I was not able to see the link light up when I did netstat -v Any idea? Thanks. (2 Replies)
Discussion started by: samnyc
2 Replies
dladm(1M)																 dladm(1M)

NAME
dladm - configure data-link interfaces SYNOPSIS
dladm show-link [-s [-i interval]] [-p] [name] dladm show-dev [-s [-i interval]] [-p] [dev] dladm create-aggr [-t] [-R root-dir] [-P policy] [-l mode] [-T time] [-u address] -d dev [-d dev] ... key dladm delete-aggr [-t] [-R root-dir] key dladm add-aggr [-t] [-R root-dir] -d dev [-d dev] ... key dladm remove-aggr [-t] [-R root-dir] -d dev [-d dev] ... key dladm modify-aggr [-t] [-R root-dir] [-P policy] [-l mode] [-T time] [-u address] key dladm show-aggr [-L] [-s [-i interval]] [-p] [key] dladm -? The dladm command is used to configure data-links. A configured data-link is represented in the system as a STREAMS DLPI (v2) interface which may be plumbed under protocol stacks such as TCP/IP. Each data-link relies on either a single network device or an aggregation of devices to send packets to or receive packets from a network. The dladm command operates on the following kinds of object: link Data-links, identified by a name aggr Aggregations of network devices, identified by a key dev Network devices, identified by concatenation of a driver name and an instance number Some devices do not support configurable data-links or aggregations. The fixed data-links provided by such devices can be viewed using dladm, but can not be configured. SUBCOMMANDS The following subcommands are supported: show-link Show configuration information for all data-links or the specified data-link. By default, the system is configured to have one data-link for each known network device. show-dev Shows information for all devices or the specified device. create-aggr Creates an aggregation using the given key value from as many dev objects as are specified. A data-link is created by default, and is given a name which is the concatenation of "aggr" and the key value of the aggregation. delete-aggr Deletes the specified aggregation. add-aggr Adds as many dev objects as are specified to the given aggregation. remove-aggr Removes as many dev objects as are specified from the given aggregation. modify-aggr Modifies the parameters of the given aggregation. show-aggr Shows configuration information for all aggregations or the specified aggregation. The following options are supported: -k key --key=key The key of an aggregation. This must be an integer value between 1 and 999. -d dev --dev=dev A device specifier. This must be a concatenation of the name and instance of the driver bound to the device. -P policy --policy=policy Specifies the port selection policy to use for load spreading of outbound traffic. The policy specifies which dev object is used to send packets. A policy consists of a list of one or more layers specifiers separated by commas. A layer specifier is one of the follow- ing: L2 Select outbound device according to source and destination MAC addresses of the packet. L3 Select outbound device according to source and destination IP addresses of the packet. L4 Select outbound device according to the upper layer protocol information contained in the packet. For TCP and UDP, this includes source and destination ports. For IPsec, this includes the SPI (Security Parameters Index.) For example, to use upper layer protocol information, the following policy can be used: -P L4 To use the source and destination MAC addresses as well as the source and destination IP addresses, the following policy can be used: -P L2,L3 -l mode --lacp-mode=mode Specifies whether LACP should be used and, if used, the mode in which it should operate. Legal values are off, active or passive. -T time --lacp-timer=time Specifies the LACP timer value. The legal values are short or long. -u address --unicast=address Specifies a fixed unicast address to be used for the aggregation. If this option is not specified then an address is automatically cho- sen from the set of addresses of the component devices. -L --lacp Specifies whether detailed LACP information should be displayed. -s --statistics Used with the show-link, show-aggr, or show-dev subcommands to show the statistics of data-links, aggregations or devices, respec- tively. -i interval --interval=interval Used with the -s option to specify an interval, in seconds, at which statistics should be displayed. If this option is not specified, statistics will only be displayed once. -t --temporary Specifies that the change is temporary. Temporary changes last until the next reboot. -R root-dir --root-dir=root-dir Specifies an alternate root directory where dladm applies changes. This can be useful in JumpStart scripts, where the root directory of the system being modified is mounted elsewhere. -p --parseable Specifies that configuration information should be displayed in parseable format. -? --help Displays help information. (Stops interpretation of subsequent arguments). EXAMPLES
Example 1: Configuring an aggregation To configure a data-link over an aggregation of devices bge0 and bge1 with key 1, enter the following command: # dladm create-aggr -d bge0 bge1 1 See attributes(5) for descriptions of the following attributes: /usr/sbin +-----------------------------+-----------------------------+ | ATTRIBUTE TYPE | ATTRIBUTE VALUE | +-----------------------------+-----------------------------+ |Availability |SUNWcsu | +-----------------------------+-----------------------------+ |Interface Stability |Evolving | +-----------------------------+-----------------------------+ /sbin +-----------------------------+-----------------------------+ | ATTRIBUTE TYPE | ATTRIBUTE VALUE | +-----------------------------+-----------------------------+ |Availability |SUNWcsr | +-----------------------------+-----------------------------+ |Interface Stability |Evolving | +-----------------------------+-----------------------------+ ifconfig(1M), attributes(5), dlpi(7P) NOTES
The configuration of all objects will persist across reboot. 28 Sep 2005 dladm(1M)
All times are GMT -4. The time now is 05:27 PM.
Unix & Linux Forums Content Copyright 1993-2022. All Rights Reserved.
Privacy Policy