02-11-2011
try a "ifconfig aggr1 down" and after that, try again with the ping. you have two interfaces in the same net/subnet. so the ping might go out through the other interface.
aggr1 is btw a link aggregation which you can have a look at with "dladm show-aggr".
This User Gave Thanks to DukeNuke2 For This Post:
10 More Discussions You Might Find Interesting
1. Cybersecurity
what is lan card autonegotiation ?
how to enable and disable this feature? (2 Replies)
Discussion started by: nabil_boussetta
2 Replies
2. SCO
Dear all
Im facing one problem in SCO 5.0.5 , its that in the server there are three LAN cards INTEL PRO 100 series but when we configure all the three cards then LAN stops working . self ping is possible but no one can ping the server. If we remove driver of any one card LAN starts working.
Is... (1 Reply)
Discussion started by: ccvyas
1 Replies
3. SuSE
Hey all, ive got redhat 80 and trying to install a HCF win modem. Ive intsalled the drivers from linuxant.com using the rpm - i packagename.rpm command, but i still cant use the modem
any suggestions ? (3 Replies)
Discussion started by: kiwi_bloke
3 Replies
4. Solaris
hello mates,
do you know a manufactor for rs232 serial pci cards for the sparc architecture? it seems that there is no original product from sun for that purpose. strange, isn't it?
problem is that i have a V250 with only one db9 rs232 serial port, and i need it for a modem connection, but i also... (1 Reply)
Discussion started by: pressy
1 Replies
5. Solaris
Hi,
i have a RealTek Lan Card on my machine. Does Solaris 9 supports this lan card .
Thank You,
Shafi (3 Replies)
Discussion started by: sol8admin
3 Replies
6. AIX
Hi everyone, I recently inherited an IBM RS/6000 43P 150, and it appears that the on board ethernet is dead. Can I put in a PCI ethernet card and use that as the default ethernet connection (as opposed to the one on the motherboard)? If so, what type of card can I use and how does one configure... (2 Replies)
Discussion started by: Jwoollard
2 Replies
7. UNIX for Dummies Questions & Answers
I have a US Robotics USR5416 wireless networking card and everytime after hours of inactivity the cardseems to shutdown. I read somewhere the it does not support power management. Is there a way to disable power management to that particular PCI card? (0 Replies)
Discussion started by: diesel440
0 Replies
8. Linux
I installed PCI Card HP SC44Ge - SAS1068E
on my linux CentOS 5.4
is there a way to find out if the PCI is properly installed and recognized by linux.
lspci is enough?
just to add that PCI card is connected to a tape...
also how can I find out driver and firmware version?
thanks a... (1 Reply)
Discussion started by: karlochacon
1 Replies
9. Solaris
Hello all,
I have a problem with my x4270_m2 server. I have a GBE lan built into the back of my server and I have a QGE pci card in slot 2 to be used as a redundant.
My server is not picking up the QGE lan card in slot2. From investigation of the /etc/path_to_inst, which shows:
#grep e1000... (2 Replies)
Discussion started by: kerrygold
2 Replies
10. AIX
Hi All,
How can I find out which is ETH5 on my AIX P5 system. I have about seven different NIC card on this. I did move the cable to each one but still I was not able to see the link light up when I did netstat -v
Any idea?
Thanks. (2 Replies)
Discussion started by: samnyc
2 Replies
LEARN ABOUT CENTOS
ocf_pacemaker_pingd
OCF_PACEMAKER_PINGD(7) Pacemaker Configuration OCF_PACEMAKER_PINGD(7)
NAME
ocf_pacemaker_pingd - pingd resource agent
SYNOPSIS
[OCF_RESKEY_pidfile=string] [OCF_RESKEY_user=string] [OCF_RESKEY_dampen=integer] [OCF_RESKEY_set=string] [OCF_RESKEY_name=string]
[OCF_RESKEY_section=string] [OCF_RESKEY_multiplier=integer] [OCF_RESKEY_host_list=string] [OCF_RESKEY_interval=integer]
[OCF_RESKEY_attempts=integer] [OCF_RESKEY_timeout=integer] [OCF_RESKEY_options=string] pingd [start | stop | monitor | meta-data |
validate-all]
DESCRIPTION
This agent (ocf:pacemaker:pingd) has been replaced by the more reliable ocf:pacemaker:ping. It records (in the CIB) the current number of
ping nodes (specified in the 'host_list' parameter) a cluster node can connect to.
SUPPORTED PARAMETERS
OCF_RESKEY_pidfile = string [/pingd-]
PID file
OCF_RESKEY_user = string [root]
The user we want to run pingd as
The user we want to run pingd as
OCF_RESKEY_dampen = integer [5s]
Dampening interval
The time to wait (dampening) further changes occur
OCF_RESKEY_set = string []
Set name
The name of the instance_attributes set to place the value in. Rarely needs to be specified.
OCF_RESKEY_name = string [pingd]
Attribute name
The name of the attributes to set. This is the name to be used in the constraints.
OCF_RESKEY_section = string []
Section name
The section place the value in. Rarely needs to be specified.
OCF_RESKEY_multiplier = integer []
Value multiplier
The number by which to multiply the number of connected ping nodes by
OCF_RESKEY_host_list = string []
Host list
The list of ping nodes to count. Defaults to all configured ping nodes. Rarely needs to be specified.
OCF_RESKEY_interval = integer [1]
ping interval in seconds
How often, in seconds, to check for node liveliness
OCF_RESKEY_attempts = integer [2]
no. of ping attempts
Number of ping attempts, per host, before declaring it dead
OCF_RESKEY_timeout = integer [2]
ping timeout in seconds
How long, in seconds, to wait before declaring a ping lost
OCF_RESKEY_options = string []
Extra Options
A catch all for any other options that need to be passed to pingd.
AUTHOR
Andrew Beekhof <andrew@beekhof.net>
Author.
Pacemaker Configuration 06/10/2014 OCF_PACEMAKER_PINGD(7)