02-11-2011
Is it really ISCSI
Is this an ISCSI NAS unit or is it really SAN with a fibre connection. If it is ISCSI NAS then how are you connecting the NAS unit, with ethernet?
10 More Discussions You Might Find Interesting
1. UNIX for Advanced & Expert Users
Hi all. I was able to set up an IBM Ultrium LTO 4 tape drive to use iSCSI (using open-iscsi drivers) to communicate with Red Hat, but it's going really slow, maxing out in tar and dd tests at like 16 MB/s (using a block size of 128k). The thing is rated for 30MB/s. I feel like even though I have... (1 Reply)
Discussion started by: jeriryan87
1 Replies
2. AIX
Hi Everyone,
I would like to know if its possible to create a 2 copy mirror using LVM with 1 member a FC attached disk and the other an iscsi disk.
Will LVM let me mirror to two different disk types?
I know there will be issues doing this however it is only a short term solution until we... (1 Reply)
Discussion started by: bizman
1 Replies
3. AIX
I just reloaded an IBM P-Series with AIX 5.3 and would like to configure iscsi, can someone point me in the right direction to obtaining the initiator node name?
I ran lsattr -El iscsi0 - but the name that is displayed is not the correct name. I read somewhere the default node name is not... (2 Replies)
Discussion started by: bbbngowc
2 Replies
4. Solaris
hi,
I have installed Solaris 10 10/08 on sparc machine. I would like to configure iSCSI on that to mount SAN Volumes. Is there any need to install any additional patches for iSCSI to work.
Thanks,
Prashant. (4 Replies)
Discussion started by: prashantbhushan
4 Replies
5. OS X (Apple)
I have configured iSCSI on server with linux running on it .
On APPLE I have downloaded gloablSAN. When globalSAN is started ,it asks for target IP . I have given target IP . It has detected the disks .
But when i use "disk utilities " , here the ISCSI disk are not displayed. except the... (0 Replies)
Discussion started by: pradeepreddy
0 Replies
6. AIX
Hi,
I have an iSCSI LUN of 200GB. I increased it to 250GB and when I try to increase the size of the vg, I'm getting an error that none of the volumes have increased in size.
How can I get the OS to see the additional 50GB?
---------- Post updated at 03:22 PM ---------- Previous update... (9 Replies)
Discussion started by: bbbngowc
9 Replies
7. Linux
Hi guys, I'd like to share experiences and knowledge about what should I use to install on a new storage server (with a lot of disks) in my network. What I want, is to move all domU's storage to this new storage server with AoE, iscsi or another thing. question:
1. Should I install openfiler or... (1 Reply)
Discussion started by: iga3725
1 Replies
8. UNIX for Dummies Questions & Answers
how to change ethernet cable of iscsi initiator (iscsi client) (0 Replies)
Discussion started by: pankajd
0 Replies
9. Solaris
Hello. I'm a noob, but have managed to get to the point of Solaris storage server running 4 X 3Tb in a RAIDZ pool. My current system is sharing via SMB a few different ZFS devices (puddle/TV, puddle/Movies, puddle/Music, etc).
My main server is going to be OSX, Mountain Lion. What I have set... (4 Replies)
Discussion started by: BillyPrefect
4 Replies
10. HP-UX
Is there one? If so where can it be found? I have the 10.20 CD set but I don't think that there's an iSCSI initiator on there.
Thank you
Dave (0 Replies)
Discussion started by: perdrix
0 Replies
LEARN ABOUT DEBIAN
rlm_expr
rlm_expr(5) FreeRADIUS Module rlm_expr(5)
NAME
rlm_expr - FreeRADIUS Module
DESCRIPTION
The rlm_expr module allows the server to perform limited mathematical calculations. This module is not called directly in any section, it
is invoked through the dynamic expansion of strings.
For example, some NAS boxes send a NAS-Port attribute which is a 32-bit number composed of port, card, and interface, all in different
bytes. To see these attributes split into pieces, you can have an entry in the 'users' file like:
DEFAULT
Vendor-Interface = `%{expr: %{NAS-Port} / (256 * 256)}`,
Vendor-Card = `%{expr: (%{NAS-Port} / 256) %% 256}`,
Vendor-Port = `%{expr: %{NAS-Port} %% 256}`
where the attributes Vendor-Interface, Vendor-Card, and Vendor-Port are attributes created by either you or a vendor-supplied dictionary.
The methematical operators supported by the expression module are:
+ addition
- subtraction
/ division
%% modulo remainder
* multiplication
& boolean AND
| boolean OR
() grouping of sub-expressions
NOTE: The modulo remainder operator is '%%', and not '%'. This is due to the '%' character being used as a special character for dynamic
translation.
NOTE: These operators do NOT have precedence. The parsing of the input string, and the calculation of the answer, is done strictly left to
right. If you wish to order the expressions, you MUST group them into sub-expression, as shown in the previous example.
All of the calculations are performed as unsigned 32-bit integers.
CONFIGURATION
modules {
...
expr {
}
...
}
...
instantiate {
...
expr
...
}
SECTIONS
instantiate
FILES
/etc/raddb/radiusd.conf
SEE ALSO
radiusd(8), radiusd.conf(5)
AUTHOR
Chris Parker, cparker@segv.org
5 February 2004 rlm_expr(5)