Operating Systems AIX Inherited VIO server an LPARs Post 302493446 by zxmaus on Wednesday 2nd of February 2011 06:51:17 PM
Old 02-02-2011
you know if you do it this way, than you loose everything if the vio server goes down ?

Apart from that why dont you just work with vscsi and redundant vio servers rather than with file backed IO - would make maintenance a lot easier I think ...
Regards
zxmaus
 

10 More Discussions You Might Find Interesting

1. SCO

Inherited server - need help

I have inherited admin duties on an old server running SCO Open Server 5. No changes have been made to this thing for a very long time. The server has started randomly disconnecting itself from the network. I have to reboot the server to get it to find the network again. It happens about once a... (3 Replies)
Discussion started by: jmickens
3 Replies

2. AIX

Virtual Ethernet VIO HMC LPARs

Hi, I am little confused about the virtual Ethernet configuration on VIO and Client Partitions. There is alot of info on the internet but it gets more confusing.... If I have LHEA, it is very simple. Just assign LHEA (logical host ethernet adapter) to client partition -> run smitty tcpip and... (10 Replies)
Discussion started by: filosophizer
10 Replies

3. AIX

vio server and vio client

Hi, I want to know wheather partition size for installation of vio client can be specified on vio server example If I am installing vio server on blade with 2*300gb hard disk,after that I want to create 2 vio client (AIX Operating system) wheather I can specify hard disk size while... (1 Reply)
Discussion started by: manoj.solaris
1 Replies

4. AIX

Identifying the vio server names

Hi My vio client is getting its virtual Ethernet services from dual vio servers. What command if I execute on the vio client will get me the names of the vio servers ? (2 Replies)
Discussion started by: samsungsamsung
2 Replies

5. AIX

VIO server on p520

trying to put VIO server software into this p520, firmware upgraded to the latest and greatest..SF240_415_318 , I think a few questions, on this practice AIX machine on AIX 7.1 VIO can only be installed if ASMI or HMC is running ??? if so, perhaps ASMI is much simpler, since I will need to... (2 Replies)
Discussion started by: ppchu99
2 Replies

6. AIX

vio server ethernet to vio client ethernet(concepts confusing)

Hi In the vio server when I do # lsattr -El hdisk*, I get a PVID. The same PVID is also seen when I put the lspv command on the vio client partition. This way Im able to confirm the lun using the PVID. Similarly how does the vio client partition gets the virtual ethernet scsi client adapter... (1 Reply)
Discussion started by: newtoaixos
1 Replies

7. AIX

Mirroring vio server

Hi, I would like to know installing vio server on local disk and mirroring rootvg, if I am creating AIX VIO CLIENT(lpar), and any of single local hard disk failuare. will it affect lpars? will lpars able to boot. what needs to be done? (1 Reply)
Discussion started by: manoj.solaris
1 Replies

8. AIX

VIO Server

Hi, I am facing an issue in vio server. When I run bosboot -ad /dev/hdisk0 I am getting an error trustchk: Verification of attributes failed: /usr/sbin/bootinfo : accessauths regards, vjm Please use code tags next time for your code and data. (8 Replies)
Discussion started by: vjm
8 Replies

9. UNIX for Advanced & Expert Users

How to identify the blade from VIO server?

Hello, I would like to identify the blade or/and bladecenter from the hosted VIO server. I prefer the "command line" solution. May be kdb. Like, I want to ask the child about his father. Thank you (1 Reply)
Discussion started by: x41
1 Replies

10. AIX

Need to replace a broken PV in a VIO VG used for client LPARs (and it won't release the old one)

I have a broken PV in a VIO VG that's used to support client LPARs using LVs. On the client LPAR, I reduced all PVs from the relevant client VG and thus deleted it. I.e. there is no client LPAR using the VIO VG. Yet when I try to reducevg the VIO VG, it complains that the LV hosted on the PV is... (2 Replies)
Discussion started by: maraixadm
2 Replies
SLAPO-MEMBEROF(5)						File Formats Manual						 SLAPO-MEMBEROF(5)

NAME
slapo-memberof - Reverse Group Membership overlay to slapd SYNOPSIS
/etc/openldap/slapd.conf DESCRIPTION
The memberof overlay to slapd(8) allows automatic reverse group membership maintenance. Any time a group entry is modified, its members are modified as appropriate in order to keep a DN-valued "is member of" attribute updated with the DN of the group. CONFIGURATION
The config directives that are specific to the memberof overlay must be prefixed by memberof-, to avoid potential conflicts with directives specific to the underlying database or to other stacked overlays. overlay memberof This directive adds the memberof overlay to the current database; see slapd.conf(5) for details. The following slapd.conf configuration options are defined for the memberof overlay. memberof-group-oc <group-oc> The value <group-oc> is the name of the objectClass that triggers the reverse group membership update. It defaults to groupOfNames. memberof-member-ad <member-ad> The value <member-ad> is the name of the attribute that contains the names of the members in the group objects; it must be DN-val- ued. It defaults to member. memberof-memberof-ad <memberof-ad> The value <memberof-ad> is the name of the attribute that contains the names of the groups an entry is member of; it must be DN-val- ued. Its contents are automatically updated by the overlay. It defaults to memberOf. memberof-dn <dn> The value <dn> contains the DN that is used as modifiersName for internal modifications performed to update the reverse group mem- bership. It defaults to the rootdn of the underlying database. memberof-dangling {ignore, drop, error} This option determines the behavior of the overlay when, during a modification, it encounters dangling references. The default is ignore, which may leave dangling references. Other options are drop, which discards those modifications that would result in dan- gling references, and error, which causes modifications that would result in dangling references to fail. memberof-dangling-error <error-code> If memberof-dangling is set to error, this configuration parameter can be used to modify the response code returned in case of vio- lation. It defaults to "constraint violation", but other implementations are known to return "no such object" instead. memberof-refint {true|FALSE} This option determines whether the overlay will try to preserve referential integrity or not. If set to TRUE, when an entry con- taining values of the "is member of" attribute is modified, the corresponding groups are modified as well. The memberof overlay may be used with any backend that provides full read-write functionality, but it is mainly intended for use with local storage backends. The maintenance operations it performs are internal to the server on which the overlay is configured and are never repli- cated. Replica servers should be configured with their own instances of the memberOf overlay if it is desired to maintain these memberOf attributes on the replicas. FILES
/etc/openldap/slapd.conf default slapd configuration file SEE ALSO
slapd.conf(5), slapd-config(5), slapd(8). The slapo-memberof(5) overlay supports dynamic configuration via back-config. ACKNOWLEDGEMENTS
This module was written in 2005 by Pierangelo Masarati for SysNet s.n.c. OpenLDAP 2.4.39 2014/01/26 SLAPO-MEMBEROF(5)
All times are GMT -4. The time now is 07:24 AM.
Unix & Linux Forums Content Copyright 1993-2022. All Rights Reserved.
Privacy Policy