Sponsored Content
Full Discussion: Anyone using NPIV?
Operating Systems AIX Anyone using NPIV? Post 302491937 by kah00na on Friday 28th of January 2011 04:53:50 PM
Old 01-28-2011
Anyone using NPIV?

Is anyone here using NPIV with AIX? If you are, what type of switch are you connected to? Also, please share some impressions of NPIV over traditional port-to-port LUN assignments. We are looking to move to NPIV and need some convincing argume... I mean information.
 

8 More Discussions You Might Find Interesting

1. AIX

Migrating hdisks from vscsi to NPIV with powerpath

Hi All, I'm preparing to migrate some servers from vscsi to pass-thru NPIV. I am planning to have the SAN team move the exact LUNs from vio1/vio2 to those two VWWN through NPIV. My question is on the partition itself.. right now, let's say I have hdisk0/1/2/3/4 that are part of datavg. They... (2 Replies)
Discussion started by: lapfrank
2 Replies

2. AIX

NPIV with 8Gb PCI Express Dual Port FC Adapter

All I am at a loss with a VIO server running ios 2.2.0.10-FP-24 SP-01. The VIO server is fitted with two 8Gb PCI Express Dual Port FC Adapters. However when I run the lsnports command only two of the adapter ports show as capable: $ lsnports name physloc ... (4 Replies)
Discussion started by: johnf
4 Replies

3. AIX

AIX Sanboot from EMC Symmetrix with NPIV

Hi All.. On to a new implementation with AIX 7.1 san boot from EMC disks (Using NPIV). Anyone played with this recently? Wondering if we need PowerPath on the AIX clients or has native MPIO matured to replace it. Thoughts? Thanks Mr B (6 Replies)
Discussion started by: balaji_prk
6 Replies

4. AIX

Vscsi and npiv on same adapter

Hi, I want to change from vscsi to npiv. Is it possible to use both on the same adapter, so we can change the systems one by one, or must we place a second FC adapter in the VIO servers? Thanks, Ronald (2 Replies)
Discussion started by: ronaldm60
2 Replies

5. AIX

NPIV mapping problem

Hello all I hope someone can help me with this. I have a single LPAR which is supplied a rootvg and datavg disk set from a dual VIO server configuration. I see dual path disks for all the datavg disks but only see one path for the rootvg disks. The client LPAR has the following: fcs0 ... (3 Replies)
Discussion started by: johnf
3 Replies

6. AIX

NPIV custom WWN

Hi All :) i would like to know if i can customize the WWN of the new VFC (NPIV). Or, if i must move the LPAR on another server with another FCS, i have to change the zoning?? Thanks in advance. Mario ---------- Post updated 09-21-12 at 02:51 AM ---------- Previous update was 09-20-12 at... (1 Reply)
Discussion started by: Zio Bill
1 Replies

7. AIX

VIOS FC Mapping/NPIV questions

Please forgive me here as I don't fully understand what I am talking about here so if I use the wrong terminology please overlook me. We have multiple AIX LPARs on the managed system with two VIO Servers. A Co-Worker and I are trying to set up a new LPAR client (The guy that knows this is out)... (14 Replies)
Discussion started by: juredd1
14 Replies

8. AIX

AIX san boot from EMC2 & NPIV

Hi all , we're implementing a new NPIV infrastructure with AIX san boot on EMC2 VMAX 5876 , for economic reason , they don't wont to install Powerpath multipath sw , but only ODM drivers from EMC2 , this behavior is supported and can work?! in the past we implemented NPIV on DS8000 family... (2 Replies)
Discussion started by: BabylonRocker76
2 Replies
VALE(4) 						   BSD Kernel Interfaces Manual 						   VALE(4)

NAME
vale -- a very fast Virtual Local Ethernet using the netmap API SYNOPSIS
device netmap DESCRIPTION
vale is a feature of the netmap(4) module that implements multiple Virtual switches that can be used to interconnect netmap clients, includ- ing traffic sources and sinks, packet forwarders, userspace firewalls, and so on. vale is implemented completely in software, and is extremely fast. On a modern machine it can move almost 20 Million packets per second (Mpps) per core with small frames, and about 70 Gbit/s with 1500 byte frames. OPERATION
vale dynamically creates switches and ports as clients connect to it using the netmap(4) API. vale ports are named vale[bdg:][port] where vale is the prefix indicating a VALE switch rather than a standard interface, bdg indicates a specific switch (the colon is a separator), and port indicates a port within the switch. Bridge and port names are arbitrary strings, the only constraint being that the full name must fit within 16 characters. See netmap(4) for details on the API. LIMITS vale currently supports up to 4 switches, 16 ports per switch, with 1024 buffers per port. These hard limits will be changed to sysctl vari- ables in future releases. SYSCTL VARIABLES
vale uses the following sysctl variables to control operation: dev.netmap.bridge The maximum number of packets processed internally in each iteration. Defaults to 1024, use lower values to trade latency with throughput. dev.netmap.verbose Set to non-zero values to enable in-kernel diagnostics. EXAMPLES
Create one switch, with a traffic generator connected to one port, and a netmap-enabled tcpdump instance on another port: tcpdump -ni vale-a:1 & pkt-gen -i vale-a:0 -f tx & Create two switches, each connected to two qemu machines on different ports. qemu -net nic -net netmap,ifname=vale-1:a ... & qemu -net nic -net netmap,ifname=vale-1:b ... & qemu -net nic -net netmap,ifname=vale-2:c ... & qemu -net nic -net netmap,ifname=vale-2:d ... & SEE ALSO
netmap(4) http://info.iet.unipi.it/~luigi/vale/ Luigi Rizzo, Giuseppe Lettieri: VALE, a switched ethernet for virtual machines, June 2012, http://info.iet.unipi.it/~luigi/vale/ AUTHORS
The vale switch was designed and implemented in 2012 by Luigi Rizzo and Giuseppe Lettieri at the Universita` di Pisa. vale was funded by the European Commission within FP7 Projects CHANGE (257422) and OPENLAB (287581). BSD
July 27, 2012 BSD
All times are GMT -4. The time now is 04:16 AM.
Unix & Linux Forums Content Copyright 1993-2022. All Rights Reserved.