Sponsored Content
Operating Systems AIX Can EtherChannel be a redundancy config? Post 302491870 by kah00na on Friday 28th of January 2011 02:08:43 PM
Old 01-28-2011
When you go into "smitty etherchannel", change/show, choose your etherchannel, look at the "Mode". You can have "standard" which means it only uses the secondary adapter when the first one loses it's connection. When this happens, you'll see something like "etherchannel failover" in the errpt. You'll see another error in the errpt when it goes back over to the primary adapters... something like "etherchannel restored" or "ether path restored"... I can't remember for sure, but you do see an event everytime it changes.

You can also set "Mode" to "round_robin" which means that it sends so many packets through one adapter and then so many packets through the other adapter and keeps switching back and forth. All this does is split your network traffic between the two adapters.

Both settings are good for redundancy. It just depends on how/if you want your data split between the two adapters.

I have personally physically removed adapters and plugged in other ones, always making sure at least one has a physical connection to the switch, and AIX handled it just fine. It recorded a bunch of errors in the errpt, but that was expected.a
 

9 More Discussions You Might Find Interesting

1. AIX

EtherChannel network redundance problem

Problem description: On the condition of EtherChannel function of AIX, when the data exchange between the nodes on the network, there sometimes lost datat packets and cause the application failed. Once we deconfig EtherChannel and use the single adapter configuration, the application works... (0 Replies)
Discussion started by: Frank2004
0 Replies

2. UNIX for Advanced & Expert Users

Port Redundancy

Dears, I have server has two port's(Enet0,Enet1) what I want as follows: Make the two port's has same IP address where, if the port Enet0 became down automaticly Enet1 become up :confused: . Amen (4 Replies)
Discussion started by: amen00
4 Replies

3. AIX

Problem with Etherchannel

I'm trying to configure Etherchannel on AIX 5.3 and I'm having some problems. I am aggregating both of the onboard NIC's (ent0 and ent1) into a new adapter ent2 for failover reasons obviously. At first I was experiencing a problem where about 50% of all my packets would be dropped. Then after... (4 Replies)
Discussion started by: acascianelli
4 Replies

4. AIX

AIX / Etherchannel / VLANs

I have 1 AIX server, 4 dual ported fiber attached ethernet cards and 4 VLANS coming in. Is it possible to present those 8 ports as 1 IP address using etherchannel? Thanks. (5 Replies)
Discussion started by: jwholey
5 Replies

5. AIX

Pb Etherchannel/deconnexion port reseau

Hello, On a partition with AIX 5300-11-01-0944. 1 etherchannel ent9 with aggregation ent3/ent7. # lsdev |grep ent ... ent3 Available 07-01 4-Port 10/100/1000 Base-TX PCI-Express Adapter (14106803) ... ent7 Available 0A-01 4-Port 10/100/1000 Base-TX PCI-Express... (2 Replies)
Discussion started by: Trunk
2 Replies

6. AIX

EtherChannel interface ping pelicularity

I have few AIX servers in my data center, which have their EtherChannel configured to have a fat pipe (active/active) and a nagios server to monitor the server uptimes. Nagios server pings every server in the data center and we have pretty much every known unix flavor in this data center. When... (3 Replies)
Discussion started by: thenomad
3 Replies

7. AIX

Aggregated Etherchannel

Hi, I have a AIX5.3 P6-520 with 8x1Gb Ethernet ports with possible connections to 2 CISCO 2960 switches. I can create 8023ad Etherchannels which work correctly with the switches (I have set up for LACP passive and a valid channels) But can create 2x 8023ad 4Gb Etherchannels with no backups.... (2 Replies)
Discussion started by: spitzie
2 Replies

8. AIX

Etherchannel failover testing

Hi Guys, I am trying to test an etherchannel failover and switchback. I did failover from primary to backup adapter, but now I am not able to switch it back to primary. phcxxxxx:/ > entstat -d ent4 | grep Active Active channel: backup adapter ... (1 Reply)
Discussion started by: snchaudhari2
1 Replies

9. AIX

PowerVM SEA etherchannel performance ?

Hello, POWER7 machine. 4 x 1Gbit port ethernet adapter is dedicated to vios. 8023ad etherchannel is created using those 4 ports. Etherchannel adapter is shared to lpars using SEA. If I test network performance directly from vios partition (using iperf) I'm geting nice 4Gbit throughput. But if... (3 Replies)
Discussion started by: vilius
3 Replies
fza(4)							     Kernel Interfaces Manual							    fza(4)

Name
       fza - DEFZA FDDI Network Interface

Syntax
       device fza0 at ibus? vector fzaintr

Description
       The  interface  is  a  high  speed  TURBOchannel  bus to a 100 Mbit/second Fiber Distributed Data Interface (FDDI) timed token ring network
       adapter.  The interface allows the host system to be an FDDI single attachment station.

       The host's Internet address is specified at boot time with an SIOCSIFADDR ioctl.  The interface employs	the  address  resolution  protocol
       described in to map dynamically between Internet and FDDI addresses on the local network.

       The maximum frame size for the interface is 4500 bytes, which is substantially larger that the 1500 bytes maximum packet size of the Ether-
       net interfaces. The interface does not support the BSD trailer encapsulation, which is specific to the VAX architecture.

       The SIOCRPHYSADDR ioctl can be used to read the physical address of the DEFZA adapter. The physical address of the DEFZA adapter can not be
       changed.

       The  SIOCADDMULTI  and  SIOCDELMULTI  ioctls  can  be  used  to	add  or delete multicast addresses.  The DEFZA supports up to 64 multicast
       addresses.

       The SIOCRDCTRS ioctl can be used to read the FDDI driver counters.  The DEFZA adapter status and characteristics can also be  read  through
       this ioctl by providing a FDDI_STATUS flag . The argument to this ioctl is a pointer to a counter or status structure, found in <net/if.h>.

       The SIOCENABLBACK and SIOCDISABLBACK ioctls can be used to enable and disable the interface loopback mode, respectively.

       The SIOCEEUPDATE ioctl can be used to update the adapter's firmware.

       The SIOCIFRESET ioctl can be used to reset the adapter.

Diagnostics
       Diagnostic error messages contain information provided by the driver. For example:

       fza%d: fzaprobe selftest failed
       The DEFZA adapter did not pass the power-up selftest during autoconfiguration.
       fza%d: port init failed
       The DEFZA adapter cannot be initialized.
       fza%d: port in the Halt State -> CNS hardware fault
       The DEFZA adapter went to the Halt state because of an adapter firmware fault.
       fza%d: LINK unavailable
       The network link went down which means that the station is not on the FDDI ring.
       fza%d: Ring Init Received
       A Ring Initialization unsolicited event has been received from the fza%d interface.

See Also
       arp(4p), inet(4f), intro(4n)

																	    fza(4)
All times are GMT -4. The time now is 04:22 AM.
Unix & Linux Forums Content Copyright 1993-2022. All Rights Reserved.
Privacy Policy