Operating Systems AIX AIX and HMC installation issue Post 302489973 by AixCraft on Sunday 23rd of January 2011 05:19:41 AM
Old 01-23-2011
HMC network

I think its just miss connection between the HMC and the LPAR,

just try to continue the installation, and you should get the login console,

if not, maybe you'll need to update you machine firmware for aix 7 support.

you can use the FLRT tool from IBM to determine what firmware your machine will need.

IBM - FLRTool

AixCraft
 

10 More Discussions You Might Find Interesting

1. AIX

AIX HMC LSCOD with space

I am trying to run the lscod command against an HMC that has managed system names with spaces. Tried enclosing the managed system names in quotes; single and double. How do I get the command to run? ssh hmcname lscod -m 'managed system 1' -t cap -r proc -c cuod Thanks, ~Donavon (0 Replies)
Discussion started by: djlerman
0 Replies

2. AIX

CDROM Issue on LPAR HMC VIO

Whenever I assign/unassign a CDROM ( RAID CTRL ) to Active LPAR from HMC, I have to reboot the LPAR. How can I do it without rebooting the LPARS. POWER6 with HMC LPARS = AIX 6.1 Any info developerWorks : AIX and UNIX : PowerVM Forum : Moving CD-ROM/DVD-ROM dynamically ... But... (5 Replies)
Discussion started by: filosophizer
5 Replies

3. AIX

HMC installation

Can i install HMC on an x86 or x64 machine.. i have (2) rs6000 44p model 170 . OS: AIX 5.3 TL 7 I want to practice HMC and LPAR. (2 Replies)
Discussion started by: dplinux
2 Replies

4. AIX

Upgrade AIX without HMC

Hi all, i would like to know if it's possible upgrade AIX 5.3 to 6.1 on a LPAR without use the HMC. so i would like to know if i must use the console to do it or i can do all from the up&running system on LPAR. Thanks in advance. Mario (4 Replies)
Discussion started by: Zio Bill
4 Replies

5. AIX

Install AIX , do i need hmc console

Hi, For installing aix on power series , do i need to install hmc first? or i can connect hmc after? Rgs, (7 Replies)
Discussion started by: prpkrk
7 Replies

6. AIX

View IP of HMC from AIX

Trying to get the IP address of the HMC connected to some servers running AIX 6 and 7. I thought this would be as easy as running 'lsrsrc IBM.MCP IPAddresses', but when I run that command, the resource is empty. Is there some where else I should be looking, or is there a reason why this resource... (5 Replies)
Discussion started by: acascianelli
5 Replies

7. AIX

HMC in VmWare NIC sl0 issue.

Hi There, First of all I'm new to *nix world, so bear with me and English is not my native tongue :) Now I'm working on the HMC 7.3.3.0 ServPack:0 base_version:20080402.1 to make it work in VmWare (testing in Workstation) I've got HMC installed and realized that network options in GUI... (8 Replies)
Discussion started by: JKat
8 Replies

8. AIX

Power8 S812L:HMC issue and ...

Hi, I just bought POWER 8 ESERVER S812L from Ebay. There is no AIX on it. I am trying to install RedHat on this box But it does not recognize the hard drive and Ethernet card. I am very newbie with IBM ... please help or hints me please ... 1. can't access to HMC ports, thought it's... (21 Replies)
Discussion started by: lilyn
21 Replies

9. AIX

AIX: DLPAR VFC - HMC v9

Hey All, I have running dual VIOS on a P9 systems, and just created a new LPAR profile. My objective is to create LPAR Client VFC adapters, and then DLPAR VFC Server adapters on the VIOS. In the HMC v9 Enhanced GUI, I have DLPAR a VFC adapter to both VIOS, however, you can't specify the... (1 Reply)
Discussion started by: aixkidbee
1 Replies

10. AIX

IBM VIOS AIX HMC Error

hello P6 was managed by HMC, tried to install on it VIOS 2.2.6 and got this error message Hosting requires a hosting partition -- boot not permitted vios-4 - imgbb.com then after creating an lpar in HMC got this message B2001230 vios-3 - imgbb.com anyone know how to solve this... (3 Replies)
Discussion started by: filosophizer
3 Replies
FENCE_AGENT(8)						      System Manager's Manual						    FENCE_AGENT(8)

NAME
fence_bladecenter - Fence agent for IBM BladeCenter DESCRIPTION
fence_bladecenter is an I/O Fencing agent which can be used with IBM Bladecenters with recent enough firmware that includes telnet support. It logs into a Brocade chasis via telnet or ssh and uses the command line interface to power on and off blades. fence_bladecenter accepts options on the command line as well as from stdin. Fenced sends parameters through stdin when it execs the agent. fence_bladecenter can be run by itself with command line options. This is useful for testing and for turning outlets on or off from scripts. Vendor URL: http://www.ibm.com PARAMETERS
-o, --action=<action> Fencing Action (Default Value: reboot) -a, --ip=<ip> IP Address or Hostname This parameter is always required. -l, --username=<name> Login Name This parameter is always required. -p, --password=<password> Login password or passphrase -S, --password-script=<script> Script to retrieve password -c, --command-prompt=<prompt> Force command prompt (Default Value: system>) -x, --ssh SSH connection -n, --plug=<id> Physical plug number or name of virtual machine This parameter is always required. -k, --identity-file=<filename> Identity file for ssh -4, --inet4-only Forces agent to use IPv4 addresses only -6, --inet6-only Forces agent to use IPv6 addresses only -u, --ipport=<port> TCP port to use for connection with device -v, --verbose Verbose mode -D, --debug-file=<debugfile> Write debug information to given file -V, --version Display version information and exit -h, --help Display help and exit -C, --separator=<char> Separator for CSV created by operation list (Default Value: ,) --power-timeout Test X seconds for status change after ON/OFF (Default Value: 20) --shell-timeout Wait X seconds for cmd prompt after issuing command (Default Value: 3) --login-timeout Wait X seconds for cmd prompt after login (Default Value: 5) --power-wait Wait X seconds after issuing ON/OFF (Default Value: 10) --missing-as-off Missing port returns OFF instead of failure --delay Wait X seconds before fencing is started (Default Value: 0) --retry-on Count of attempts to retry power on (Default Value: 1) ACTIONS
on Power on machine. off Power off machine. reboot Reboot machine. status This returns the status of the plug/virtual machine. list List available plugs with aliases/virtual machines if there is support for more then one device. Returns N/A otherwise. monitor Check if fencing device is running. List available plugs/virtual machines or get status of machine (if it does not support more). metadata The operational behavior of this is not known. STDIN PARAMETERS
action Fencing Action (Default Value: reboot) ipaddr IP Address or Hostname This parameter is always required. login Login Name This parameter is always required. passwd Login password or passphrase passwd_script Script to retrieve password cmd_prompt Force command prompt (Default Value: system>) secure SSH connection port Physical plug number or name of virtual machine This parameter is always required. identity_file Identity file for ssh inet4_only Forces agent to use IPv4 addresses only inet6_only Forces agent to use IPv6 addresses only ipport TCP port to use for connection with device verbose Verbose mode debug Write debug information to given file version Display version information and exit help Display help and exit separator Separator for CSV created by operation list (Default Value: ,) power_timeout Test X seconds for status change after ON/OFF (Default Value: 20) shell_timeout Wait X seconds for cmd prompt after issuing command (Default Value: 3) login_timeout Wait X seconds for cmd prompt after login (Default Value: 5) power_wait Wait X seconds after issuing ON/OFF (Default Value: 10) missing_as_off Missing port returns OFF instead of failure delay Wait X seconds before fencing is started (Default Value: 0) retry_on Count of attempts to retry power on (Default Value: 1) fence_bladecenter (Fence Agent) 2009-10-20 FENCE_AGENT(8)
All times are GMT -4. The time now is 05:18 PM.
Unix & Linux Forums Content Copyright 1993-2022. All Rights Reserved.
Privacy Policy