12-27-2010
No the ni_vio1_lv is not mapped to any other vhost...
but anyway problem was solved by renaming ni_vio1_lv and therefore LVCB was updated and mapping was successful... Thanks for your reply :-)
10 More Discussions You Might Find Interesting
1. AIX
We have a frame the uses 2 vios that assign disk storage to LPAR's. We have a LPAr with multiple disk and I want to know how do I tell which vio is serving the disk. For example the LPAr has hdisk 0, 1, 2, 3 all the same size. I want to know which vio is serving hdisk0, 1. (4 Replies)
Discussion started by: daveisme
4 Replies
2. AIX
Hello guys,
It would be so nice of you if someone can provide me with these informations.
1) My SAN group assigned 51G of LUN space to the VIO server.I ran cfgdev to discover the newly added LUN. Unfortunately most of the disks that are in VIO server is 51G. How would I know which is the newly... (3 Replies)
Discussion started by: solaix14
3 Replies
3. AIX
I have a DUAL VIO ( IBM Virtual I/O ) setup on p 570.
Two Vio server ( VIOS ) and many LPAR clients.
VIO ( latest version + service pack + applied the fix ) and AIX 6.1 ML2
When both VIOs are running, and if I turn on a Client LPAR, the LPAR hangs at LED 25b3 for more than 1 hour then it... (2 Replies)
Discussion started by: filosophizer
2 Replies
4. AIX
Hi All,
Besides the licenses on VIO and LPAR. What's the main difference with the two? I have installed VIO, my manager told me so, because it's like a free hypervisor but I never installed LPAR before. How do you install it? And if you can give more info on the two, that would be great.
... (5 Replies)
Discussion started by: itik
5 Replies
5. AIX
Please forgive me here as I don't fully understand what I am talking about here so if I use the wrong terminology please overlook me.
We have multiple AIX LPARs on the managed system with two VIO Servers. A Co-Worker and I are trying to set up a new LPAR client (The guy that knows this is out)... (14 Replies)
Discussion started by: juredd1
14 Replies
6. AIX
Hi guys,
does anyone know how to get a list of the LPAR running on VIOS?
Thanks! (5 Replies)
Discussion started by: cecco16
5 Replies
7. AIX
I am trying to install AIX 5.3 on one of the LPARs through VIOS but I get this error 0518
Reference Code Selection
0518 (Time stamp: 12/18/12 12:10:20 AM UTC)
Starting kernel (Time stamp: 12/18/12 12:10:15 AM UTC)
AIX is starting. (Time stamp: 12/18/12 12:10:15 AM... (10 Replies)
Discussion started by: filosophizer
10 Replies
8. AIX
Hi,
Just joined to new company with one Power 720 Express (8202-E4C) server and have no much experience with IBM systems.
I am trying to move everything I mentioned to different subnet as required by customer contract (currently sitting on same subnet as company lan). Access to this subnet will... (8 Replies)
Discussion started by: spricer
8 Replies
9. AIX
Hello,
VIOS 2.2.1.4 using IVM.
I'm trying to extend a virtual disk assigned to a running lpar so that I can expand the lpar's datavg and grow some filesystems for the user.
Storage admin expanded the lun and new size was reflected in VIO right away. I then needed the storage pool to... (2 Replies)
Discussion started by: j_aix
2 Replies
10. UNIX for Advanced & Expert Users
Hi everybody,
I have Power5 server with 4 internal hdisks each of 70Gb.
VIOS server was installed via Virtual I/O Server Image Repository on the HMC.
HMC release - 7.7.0
VIOS rootvg installed on 2 disk(these disks merged to one storage pool during VIOS install process),and 2 others hdisks... (2 Replies)
Discussion started by: Ravil Khalilov
2 Replies
LEARN ABOUT SUSE
streqvcmp
streqvcmp(3) Programmer's Manual streqvcmp(3)
NAME
streqvcmp - compare two strings with an equivalence mapping
SYNOPSIS
#include <your-opts.h>
cc [...] -o outfile infile.c -lopts [...]
int streqvcmp(char const* str1, char const* str2);
DESCRIPTION
Using a character mapping, two strings are compared for "equivalence". Each input character is mapped to a comparison character and the
mapped-to characters are compared for the two NUL terminated input strings. This function name is mapped to option_streqvcmp so as to not
conflict with the POSIX name space.
str1 first string
str2 second string
RETURN VALUE
the difference between two differing characters
ERRORS
none checked. Caller responsible for seg faults.
SEE ALSO
The info documentation for the -lopts library.
ao_string_tokenize(3), configFileLoad(3), optionFileLoad(3), optionFindNextValue(3), optionFindValue(3), optionFree(3), optionGetValue(3),
optionLoadLine(3), optionNextValue(3), optionOnlyUsage(3), optionProcess(3), optionRestore(3), optionSaveFile(3), optionSaveState(3),
optionUnloadNested(3), optionVersion(3), pathfind(3), strequate(3), streqvmap(3), strneqvcmp(3), strtransform(3),
2010-07-05 streqvcmp(3)