Sponsored Content
Full Discussion: Openserver 5.0.6 on VMware
Operating Systems SCO Openserver 5.0.6 on VMware Post 302482779 by KevinGB on Wednesday 22nd of December 2010 01:42:49 PM
Old 12-22-2010
Is anybody out there using SCO Openserver 5.0.6 on VMware that can tell me what type of virtual hard drive and ethernet card they have used and if they are aware of any problems?
 

10 More Discussions You Might Find Interesting

1. UNIX for Dummies Questions & Answers

Help For SCO OpenServer

I've just installed Unix SCO OpenServer System v in an Intel PC and Everithing ok, except just one thing, in the begining of the installation the wizard asked me about the mouse , i have a generic 3 buttons mouse and i took a logitech and did not work i need to change the mouse configuration, ... (2 Replies)
Discussion started by: jimmyvaldes
2 Replies

2. UNIX for Dummies Questions & Answers

sco openserver 5.5

hello! when i try to make my system dual boot with both win98 & sco open server 5.5 it doesn't work at all.neither win98 take start nor sco open server boots.what should i do ? kindly help me thanks (1 Reply)
Discussion started by: buntty
1 Replies

3. UNIX for Advanced & Expert Users

SCO 5.0.2 openserver

I am doing some work for a customer that is running SCO 5.0.2 openserver and they have lost their cd. Is there anyplace I can download it? I have a replacement being shipped but it will not be here for two days and they are down. Any ideals? (3 Replies)
Discussion started by: SCOoT
3 Replies

4. UNIX for Dummies Questions & Answers

browser for openserver 5.0.4

I'm running SCO Unix openserver 5.0.4 at the moment. The problem is my dissatifaction with the web browser netscape 3.01. I wanted a better browser, and tried to install netscape 4.7, and the required rs504c patch. I'm still not able to see web pages in a satisfying matter, it is mostly black. I... (0 Replies)
Discussion started by: cantona007
0 Replies

5. UNIX for Dummies Questions & Answers

SCO Openserver 6.0

Hi there guys. I just got this new SCO version and i'm having some problem printing from shell, This is what i'm typing at the # sign : lp -dHP /etc/hosts and it prints no problem but when i use any other user at the $ sign it gives me this error. /dev/fd/7: /usr/lib/lp/sysv/7: not found. ... (1 Reply)
Discussion started by: josramon
1 Replies

6. SCO

sco openserver 5.0.7

Dear members when i installed dual processor patch in openserver 5.0.7 in hp ML370 G4 server it hangs in sco at G_hd_config. i tried MP4, EFS 5.64,5.70A but not solved the problem.. (0 Replies)
Discussion started by: M_farooqui
0 Replies

7. SCO

Openserver 6.0 changes time

Here is an odd one. Every time that our server is restarted, the time is changed by 1 hour. I'm located in Puerto Rico which is GMT -4:00. I've tried EST and AST but the problem continues. Anyone has any ideas as to the cause? Juan Navarrete (0 Replies)
Discussion started by: jn5519
0 Replies

8. SCO

Openserver 6.0.0

I spent last weekend building a new system for a client. The old (current production) system is an Acer Altos G700 with 512mb memory, dual P4 2.4ghz processors, dual channel LSI RAID controller with 4 72gb Seagate disks. This system runs SCO 5.0.7 with MPX and all the patches applied. The test... (4 Replies)
Discussion started by: jgt
4 Replies

9. SCO

openserver 5.0.6 media need

I am looking for openserver 5.0.6 media. I need build a new production server and we only have the 5.0.5 media. If anybody can help that be awesome. (9 Replies)
Discussion started by: stlwindadmin
9 Replies

10. UNIX for Advanced & Expert Users

OpenServer 6.0v installation

Hi: I'm installing SCO Open Server 6.0v on VMWare ESXi, The instalation procedure giving by UnXis is using OVF deploy template and it create a primary partition of 10gb only. Any one know, if the OVF template could be edited to create a larger partition?? Thanks (0 Replies)
Discussion started by: Ccarballo
0 Replies
FENCE_AGENT(8)						      System Manager's Manual						    FENCE_AGENT(8)

NAME
fence_vmware - Fence agent for VMWare DESCRIPTION
fence_vmware is an I/O Fencing agent which can be used with the VMware ESX, VMware ESXi or VMware Server to fence virtual machines. Before you can use this agent, it must be installed VI Perl Toolkit or vmrun command on every node you want to make fencing. VI Perl Toolkit is preferred for VMware ESX/ESXi and Virtual Center. Vmrun command is only solution for VMware Server 1/2 (this command will works against ESX/ESXi 3.5 up2 and VC up2 too, but not cluster aware!) and is available as part of VMware VIX API SDK package. VI Perl and VIX API SDK are both available from VMware web pages (not int RHEL repository!). You can specify type of VMware you are connecting to with -d switch (or vmware_type for stdin). Possible values are esx, server2 and server1.Default value is esx, which will use VI Perl. With server1 and server2, vmrun command is used. After you have successfully installed VI Perl Toolkit or VIX API, you should be able to run fence_vmware_helper (part of this agent) or vmrun command. This agent supports only vmrun from version 2.0.0 (VIX API 1.6.0). fence_vmware accepts options on the command line as well as from stdin. Fenced sends parameters through stdin when it execs the agent. fence_vmware can be run by itself with command line options. This is useful for testing and for turning outlets on or off from scripts. Vendor URL: http://www.vmware.com PARAMETERS
-o, --action=<action> Fencing Action (Default Value: reboot) -a, --ip=<ip> IP Address or Hostname This parameter is always required. -l, --username=<name> Login Name This parameter is always required. -p, --password=<password> Login password or passphrase -S, --password-script=<script> Script to retrieve password -n, --plug=<id> Physical plug number or name of virtual machine This parameter is always required. -e, --exec=<command> Command to execute -d, --vmware_type=<type> Type of VMware to connect (Default Value: esx) -x, --ssh SSH connection (Default Value: true) -k, --identity-file=<filename> Identity file for ssh -s, --vmware-datacenter=<dc> Show only machines in specified datacenter -v, --verbose Verbose mode -D, --debug-file=<debugfile> Write debug information to given file -V, --version Display version information and exit -h, --help Display help and exit -C, --separator=<char> Separator for CSV created by operation list (Default Value: ,) --power-timeout Test X seconds for status change after ON/OFF (Default Value: 20) --shell-timeout Wait X seconds for cmd prompt after issuing command (Default Value: 3) --login-timeout Wait X seconds for cmd prompt after login (Default Value: 5) --power-wait Wait X seconds after issuing ON/OFF (Default Value: 0) --delay Wait X seconds before fencing is started (Default Value: 0) --retry-on Count of attempts to retry power on (Default Value: 1) ACTIONS
on Power on machine. off Power off machine. reboot Reboot machine. status This returns the status of the plug/virtual machine. list List available plugs with aliases/virtual machines if there is support for more then one device. Returns N/A otherwise. monitor Check if fencing device is running. List available plugs/virtual machines or get status of machine (if it does not support more). metadata The operational behavior of this is not known. STDIN PARAMETERS
action Fencing Action (Default Value: reboot) ipaddr IP Address or Hostname This parameter is always required. login Login Name This parameter is always required. passwd Login password or passphrase passwd_script Script to retrieve password port Physical plug number or name of virtual machine This parameter is always required. exec Command to execute vmware_type Type of VMware to connect (Default Value: esx) secure SSH connection (Default Value: true) identity_file Identity file for ssh vmware_datacenter Show only machines in specified datacenter verbose Verbose mode debug Write debug information to given file version Display version information and exit help Display help and exit separator Separator for CSV created by operation list (Default Value: ,) power_timeout Test X seconds for status change after ON/OFF (Default Value: 20) shell_timeout Wait X seconds for cmd prompt after issuing command (Default Value: 3) login_timeout Wait X seconds for cmd prompt after login (Default Value: 5) power_wait Wait X seconds after issuing ON/OFF (Default Value: 0) delay Wait X seconds before fencing is started (Default Value: 0) retry_on Count of attempts to retry power on (Default Value: 1) fence_vmware (Fence Agent) 2009-10-20 FENCE_AGENT(8)
All times are GMT -4. The time now is 10:53 PM.
Unix & Linux Forums Content Copyright 1993-2022. All Rights Reserved.
Privacy Policy