Dear Duke,

Thanks for the reply,

Yes I am going to put RAID 1 , if i want to use with different controllers , how can i do it. And also where can i find the controllers information in solaris. So that I can use the available controllers.

Thanks and Regards
Jr
 

9 More Discussions You Might Find Interesting

1. Filesystems, Disks and Memory

Raid 1+0 ?

My cutomer wants to set up a OS/apps server with two 72GB drives configured with RAID 1+0. The way I understand RAID 1+0 is that if there was a drive failure the whole OS/apps is lost because you actually need at least 4 drives to set up a RAID 1+0 by splitting them up into two arrays. Am I... (4 Replies)
Discussion started by: bdsffl
4 Replies

2. Solaris

regarding RAID.....

hai everybody n good morning........here r some queries....... 1. what is the interlace value in RAID 0 (striping.......) 2. How many no of metadevices are required for mirroring and why......... (1 Reply)
Discussion started by: sudhansu
1 Replies

3. Solaris

RAID 0+1 Vs RAID 1+0

hi all...sudhansu here............ i need some help.......... what is RAID 0+1 and RAID 1+0.............what is the difference between them................ suppose i have 80 gb disk space,then which RAID level i follow n why......... i need redundancy n maximum storage..........please help (3 Replies)
Discussion started by: sudhansu
3 Replies

4. UNIX for Dummies Questions & Answers

RAID software vs hardware RAID

Hi Can someone tell me what are the differences between software and hardware raid ? thx for help. (2 Replies)
Discussion started by: presul
2 Replies

5. Solaris

Creation of Raid 01 and Raid 10

Hello All, I have read enough of texts on Raid 01 and Raid 10 on solaris :wall: . But no-where found a way to create them using SVM. Some one pls tell me how to do or Post some link if that helps. TIA Curious solarister (1 Reply)
Discussion started by: Solarister
1 Replies

6. AIX

SCSI PCI - X RAID Controller card RAID 5 AIX Disks disappeared

Hello, I have a scsi pci x raid controller card on which I had created a disk array of 3 disks when I type lspv ; I used to see 3 physical disks ( two local disks and one raid 5 disk ) suddenly the raid 5 disk array disappeared ; so the hardware engineer thought the problem was with SCSI... (0 Replies)
Discussion started by: filosophizer
0 Replies

7. UNIX for Dummies Questions & Answers

Need help with RAID.

Hi Gurus, Can any one explain me the difference between hardware RAID and s/w RAID. Thanks in Advance. (1 Reply)
Discussion started by: rama krishna
1 Replies

8. Solaris

Software RAID on top of Hardware RAID

Server Model: T5120 with 146G x4 disks. OS: Solaris 10 - installed on c1t0d0. Plan to use software raid (veritas volume mgr) on c1t2d0 disk. After format and label the disk, still not able to detect using vxdiskadm. Question: Should I remove the hardware raid on c1t2d0 first? My... (4 Replies)
Discussion started by: KhawHL
4 Replies

9. Red Hat

RAID Configuration for IBM Serveraid-7k SCSI RAID Controller

Hello, I want to delete a RAID configuration an old server has. Since i haven't the chance to work with the specific raid controller in the past can you please help me how to perform the configuraiton? I downloaded IBM ServeRAID Support CD but i wasn't able to configure the video card so i... (0 Replies)
Discussion started by: @dagio
0 Replies
CGEXEC(1)							 libcgroup Manual							 CGEXEC(1)

NAME
cgexec - run the task in given control groups SYNOPSIS
cgexec [-h] [-g <controllers>:<path>] [--sticky] command [arguments] DESCRIPTION
The cgexec program executes the task command with arguments arguments in the given control groups. -g <controllers>:<path> defines the control groups in which the task will be run. controllers is a list of controllers and path is the relative path to control groups in the given controllers list. This flag can be used multiple times to define multiple pairs of lists of controllers and relative paths. Instead of the list of all mounted controllers, the wildcard b"*b" can be used. If this option is not used, cgexec will automatically place the task in the right cgroup based on /etc/cgrules.conf. If /etc/cgrules.conf configuration file is used, there can be used template names. Then the control group name contains a template in destination tag (see cgrules.conf (5)) and if the cgroup does not exist in execution time, it is created, based on /etc/cgcon- fig.conf specification. If the specifications are not present the group is created with the default kernel values. -h, --help Display this help and exit. --sticky If running the task command with this option, the daemon of service cgred (cgrulesengd process) does not change both the task of the command and the child tasks. Without this option, the daemon does not change the task of the command but it changes the child tasks to the right cgroup based on /etc/cgrules.conf automatically. EXAMPLES
cgexec -g *:test1 ls runs command ls in control group test1 in all mounted controllers. cgexec -g cpu,memory:test1 ls -l runs command ls -l in control group test1 in controllers cpu and memory. cgexec -g cpu,memory:test1 -g swap:test2 ls -l runs command ls -l in control group test1 in controllers cpu and memory and control group test2 in controller swap. ENVIRONMENT VARIABLES
CGROUP_LOGLEVEL controls verbosity of the tool. Allowed values are DEBUG, INFO, WARNING or ERROR. FILES
/etc/cgrules.conf default libcgroup configuration file SEE ALSO
cgrules.conf (5) Linux 2009-03-15 CGEXEC(1)