Quote:
If I have many shared variables (more than 100), what is the better solution?
Without knowing the problem you are trying to solve, my reply might be off the track.

BUT reading "I have more than 100 variables to synchronize between threads" rings to me bells like "subtle, sporadic bugs, headache debugging and unmaintainable code"... Try to refactor your code to get as less shared variables as possible.

Loïc
 

9 More Discussions You Might Find Interesting

1. Shell Programming and Scripting

Convert file from Unix - ANSI to PC - ANSI

Hi, I am creating a file in Unix using a shell script. The file is getting created in the Unix - ANSI format. My requirement is to convert it to the PC - ANSI format. Can anyone tell me how to do this? Thanks, Sunil (0 Replies)
Discussion started by: ssmallya
0 Replies

2. Programming

pthread_rwlock_lock vs pthread_mutex_lock

I have been wondering what the difference between pthread_rwlock_lock and pthread_mutex_lock is. Both these routines acquire an exclusive rw lock on an enclosed region. So I performed a simple experiment in which I execute both these routines multiple times in a loop. Here are the results:... (1 Reply)
Discussion started by: kmehta
1 Replies

3. Programming

Interesting issue with pthread_mutex_lock and siglongjmp in AIX 5.3 (and no other OS)

Executive summary: Code (posted below) cores in AIX 5.3, despite being compiled and run successfully on several other operating systems. Code is attempting to verify that pthread_mutex_lock can be successfully aborted by siglongjmp. I do not believe this is an unreasonable requirement. If... (1 Reply)
Discussion started by: DreamWarrior
1 Replies

4. Shell Programming and Scripting

program name and function name builtins

Hi Is there a way to get the program/script name or function name usng built ins. Like in many languages arg holds the program name regards (2 Replies)
Discussion started by: xiamin
2 Replies

5. Programming

why the implementatoin of Bakery algorithm in ANSI C does not work in ANSI C

I follow the description of wiki (Lamport's bakery algorithm - Wikipedia, the free encyclopedia), then implement that algorithm in C, but it doesn't work, Starving is still here, is the implementation worry? Only print out: Thread ID: 0 START! Thread ID: 0 END! Thread ID: 0 START!... (2 Replies)
Discussion started by: sehang
2 Replies

6. UNIX for Advanced & Expert Users

Writing Custom Builtins for KSH93

I am looking to create some ksh93 extensions using the custom builtin feature. I can successfully create a builtin function, load it using the builtin -f command and get an output. However, I want to get/set values of KSH variables from within my built-in. For example, lets say I am creating... (2 Replies)
Discussion started by: a_programmer
2 Replies

7. UNIX for Dummies Questions & Answers

Why does /bin contain binaries for builtins?

Why do shell builtins like echo and pwd have binaries in /bin? When I do which pwd, I get the one in /bin. that means that I am not using the builtin version? What determines which one gets used? Is the which command a definitive way to determine what is being run when I enter pwd? (16 Replies)
Discussion started by: glev2005
16 Replies

8. Programming

Using ANSI color codes in gcc compiled program

I have put some yellow color codes and works well. I call the funstion using print_usage(stderr, 0); I would like to know if there is any way, to store the ansi color codes in variables and then call them inside fprintf. Or have a format followed by the strings I want to output. ... (5 Replies)
Discussion started by: kristinu
5 Replies

9. UNIX for Dummies Questions & Answers

Shell and bash builtins...

Not sure if this is the right forum but I have collated a listing of shell and bash builtins. Builtins is a loose word and may include the '/bin' drawer/folder/directory but NOT any others in the path list. In the case of my Macbook Pro, OSX 10.7.5 the enabled internals is also listed... ... (1 Reply)
Discussion started by: wisecracker
1 Replies
condition(5)						Standards, Environments, and Macros					      condition(5)

NAME
condition - concepts related to condition variables DESCRIPTION
Occasionally, a thread running within a mutex needs to wait for an event, in which case it blocks or sleeps. When a thread is waiting for another thread to communicate its disposition, it uses a condition variable in conjunction with a mutex. Although a mutex is exclusive and the code it protects is sharable (at certain moments), condition variables enable the synchronization of differing events that share a mutex, but not necessarily data. Several condition variables may be used by threads to signal each other when a task is complete, which then allows the next waiting thread to take ownership of the mutex. A condition variable enables threads to atomically block and test the condition under the protection of a mutual exclusion lock (mutex) until the condition is satisfied. If the condition is false, a thread blocks on a condition variable and atomically releases the mutex that is waiting for the condition to change. If another thread changes the condition, it may wake up waiting threads by signaling the associated condition variable. The waiting threads, upon awakening, reacquire the mutex and re-evaluate the condition. Initialize Condition variables and mutexes should be global. Condition variables that are allocated in writable memory can synchronize threads among processes if they are shared by the cooperating processes (see mmap(2)) and are initialized for this purpose. The scope of a condition variable is either intra-process or inter-process. This is dependent upon whether the argument is passed implic- itly or explicitly to the initialization of that condition variable. A condition variable does not need to be explicitly initialized. A condition variable is initialized with all zeros, by default, and its scope is set to within the calling process. For inter-process syn- chronization, a condition variable must be initialized once, and only once, before use. A condition variable must not be simultaneously initialized by multiple threads or re-initialized while in use by other threads. Condition variables attributes may be set to the default or customized at initialization. POSIX threads even allow the default values to be customized. Establishing these attributes varies depending upon whether POSIX or Solaris threads are used. Similar to the distinctions between POSIX and Solaris thread creation, POSIX condition variables implement the default, intra-process, unless an attribute object is modified for inter-process prior to the initialization of the condition variable. Solaris condition variables also implement as the default, intra-process; however, they set this attribute according to the argument, type, passed to their initialization function. Condition Wait The condition wait interface allows a thread to wait for a condition and atomically release the associated mutex that it needs to hold to check the condition. The thread waits for another thread to make the condition true and that thread's resulting call to signal and wakeup the waiting thread. Condition Signaling A condition signal allows a thread to unblock the next thread waiting on the condition variable, whereas, a condition broadcast allows a thread to unblock all threads waiting on the condition variable. Destroy The condition destroy functions destroy any state, but not the space, associated with the condition variable. ATTRIBUTES
See attributes(5) for descriptions of the following attributes: +-----------------------------+-----------------------------+ | ATTRIBUTE TYPE | ATTRIBUTE VALUE | +-----------------------------+-----------------------------+ |MT-Level |MT-Safe | +-----------------------------+-----------------------------+ SEE ALSO
fork(2), mmap(2), setitimer(2), shmop(2), cond_broadcast(3C), cond_destroy(3C), cond_init(3C), cond_signal(3C), cond_timedwait(3C), cond_wait(3C), pthread_cond_broadcast(3C), pthread_cond_destroy(3C), pthread_cond_init(3C), pthread_cond_signal(3C), pthread_cond_timed- wait(3C), pthread_cond_wait(3C), pthread_condattr_init(3C), signal(3C), attributes(5), mutex(5), standards(5) NOTES
If more than one thread is blocked on a condition variable, the order in which threads are unblocked is determined by the scheduling pol- icy. USYNC_THREAD does not support multiple mapplings to the same logical synch object. If you need to mmap() a synch object to different loca- tions within the same address space, then the synch object should be initialized as a shared object USYNC_PROCESS for Solaris, and PTHREAD_PROCESS_PRIVATE for POSIX. SunOS 5.10 20 Jul 1998 condition(5)
All times are GMT -4. The time now is 03:38 AM.
Unix & Linux Forums Content Copyright 1993-2022. All Rights Reserved.
Privacy Policy