Hi expert,
Need some help on network interface issue..
I have added 2 x NIC card onto the Ultra 2 system recently and configured as hme1 and hme2. I have unconfigured the onboard hme0 network interface and it was running fine till few days later, i keep recieving error messages showing hme0... (6 Replies)
Hi guys,
Hope somebody can help me on this. I have a Sun Sparc 20 workstation and it has a boot problem. During boot, an error message " ifconfig:socket: Bad File Number" come up and the workstation hang (cannot boot).
I did boot -s and checked using ifconfig -a command but i got the same... (0 Replies)
Hi every body,
I have a Fiber Channel interface (fcs2) in AIX 5.2. This interface was fine & up but for some reason I could not return this interface UP again after I set it DOWN.
When I tried to set this interface UP I encountered the following error:
Method error... (7 Replies)
My system info is show below:-
#uname -a
SunOS qfserver 5.8 Generic_117350-29 sun4u sparc SUNW,Sun-Blade-2500
and I have two network card as shown below:-
#ifconfig -a
lo0: flags=1000849<UP,LOOPBACK,RUNNING,MULTICAST,IPv4> mtu 8232 index 1
inet 127.0.0.1 netmask ff000000
bge0:... (1 Reply)
Hi
i have replace a NIC card on solaris 10 when i give the following command
ifconfig -a
it just show the lo0 (only loop back with inet 127.0.0.1)
when i give the following command to config the interface,
ifconfig elxl0 plumb
ifconfig: plumb: elxl0: no such interface
please help... (11 Replies)
i need to configure a zone to use different interface (bge2) than global and have connected to completely different network switch & to use its own defaultrouter and hosts file .. is it possible ..if so ..how ?
Thanks (9 Replies)
Hi,
I'm a italian student. For my thesis I develop a gateway with protocol 6lowpan.
For that I must access to network interface to develope my personal stack based on standard 802.15.4.
Can you help me? I need an explanation for that. (0 Replies)
I've one Netra 240
After changing main board and system configuration card reader, Network is not accessible any more, Network interfaces are always UP and Running even when there is no cable connected to Network interfaces.
I tried to restart and plumb/unplumb with no luck.
ifconfig -a... (7 Replies)
I have a RHEL 5 system with a bonded interface configure using only one network port (eth0). So I have config file for ifcfg-bond0 and ifcfg-eth. I'd like to configure eth5 to be the second SLAVE in the bond. My question is, after I modify ifcfg-eth5, can I add eth5 to the bond0 interface without... (1 Reply)
Discussion started by: westmoreland
1 Replies
LEARN ABOUT REDHAT
ppmtosixel
ppmtosixel(1) General Commands Manual ppmtosixel(1)NAME
ppmtosixel - convert a portable pixmap into DEC sixel format
SYNOPSIS
ppmtosixel [-raw] [-margin] [ppmfile]
DESCRIPTION
Reads a portable pixmap as input. Produces sixel commands (SIX) as output. The output is formatted for color printing, e.g. for a DEC
LJ250 color inkjet printer.
If RGB values from the PPM file do not have maxval=100, the RGB values are rescaled. A printer control header and a color assignment table
begin the SIX file. Image data is written in a compressed format by default. A printer control footer ends the image file.
OPTIONS -raw If specified, each pixel will be explicitly described in the image file. If -raw is not specified, output will default to com-
pressed format in which identical adjacent pixels are replaced by "repeat pixel" commands. A raw file is often an order of magni-
tude larger than a compressed file and prints much slower.
-margin
If -margin is not specified, the image will be start at the left margin (of the window, paper, or whatever). If -margin is speci-
fied, a 1.5 inch left margin will offset the image.
PRINTING
Generally, sixel files must reach the printer unfiltered. Use the lpr -x option or cat filename > /dev/tty0?.
BUGS
Upon rescaling, truncation of the least significant bits of RGB values may result in poor color conversion. If the original PPM maxval was
greater than 100, rescaling also reduces the image depth. While the actual RGB values from the ppm file are more or less retained, the
color palette of the LJ250 may not match the colors on your screen. This seems to be a printer limitation.
SEE ALSO ppm(5)AUTHOR
Copyright (C) 1991 by Rick Vinci.
26 April 1991 ppmtosixel(1)