Sponsored Content
Operating Systems SCO Noob needs help with Sco Unixware 7.1 Post 302453592 by jgt on Wednesday 15th of September 2010 09:13:55 PM
Old 09-15-2010
My guess is that it can't find the RAID controller. Will the old system boot from the Microlite boot diskettes. You should get a MSDOS style drop down menu if you are successful.
 

8 More Discussions You Might Find Interesting

1. Filesystems, Disks and Memory

SCO Unixware 2.1

I am using SCO Unixware 2.1 & some PC clients are connected, suddenly one message appearslike : UX:strintercept error: dropping message this message starts coming repeatedly & agtre some time system hangs.I had to reset the system & now the problem is not there.Please suggest, why this is... (0 Replies)
Discussion started by: paprch
0 Replies

2. UNIX for Dummies Questions & Answers

SCO Unixware 7 download

According to this thread: https://www.unix.com/showthread.php?t=1 one guy says However, I cannot find any sco unixware7 iso download link in their download section (http://wdb1.sco.com/clbk_web/owa/dwn_customer), is it really for free, and if that is true, where can I download it? Thanks, (2 Replies)
Discussion started by: phalcos
2 Replies

3. SCO

Samba 3.0.24 in SCO UnixWare 7.1.4

Please help me in troubleshooting my problem in Samba? I tried to instal Samba 3.0.24 in our SCO UnixWare 7.1.4 but after installing the nmbd daemon is not running. When i check the syslog from /var/adm, the following error appears: Sep 30 13:04:22 unixeei nmbd: bind failed on port 137... (0 Replies)
Discussion started by: eric_hing
0 Replies

4. SCO

sco unixware + oracle 8.0.5

hi, anybody can give procedure for how to install oracle 8.0.5 in sco unixware 7.1.4. (0 Replies)
Discussion started by: prakrithi
0 Replies

5. SCO

SCO noob please help

hello, sco openserver R5 the following error and it fails to load. init: Command is respawning too rapidily id: vm "/home/bin/stvm.sh" init: Comand..etc id: c02"/etc/start/autostart" its trying to mount car diagnostic program in vmware, the program location is in "start" i think? i... (1 Reply)
Discussion started by: hgibbs8129
1 Replies

6. SCO

SCO Unixware 7.1.1 Install - Need help

(sorry my English, is really poor). I have a SCO Unixware 7.1.1 and I need install in ML350 G3. Reading in google and HP web, make a floppy disks for install, but the options that I have is for network or floppy disk. How install from CD with patch for HP smart array 532 ?? or How... (5 Replies)
Discussion started by: xplertor
5 Replies

7. SCO

My UnixWare SCO Server

Hi, I'm new to this Unix world and have taken over looking after the I.T side of things at work, which includes the internal ERP system which runs on a UNIX SCO platform. My initial worry is what state this is in as its been on site over 20 years. What would be the first things to check on... (13 Replies)
Discussion started by: Mick_Dundee
13 Replies

8. SCO

Need Help with installtion of SCO UNIXware 7.0.1

Hi, I need help to install SCO Unixware 7.0.1. Can any one help with any documentation or installation notes for SCO Unixware 7.0.1. Thank you (1 Reply)
Discussion started by: farhandalvi
1 Replies
dpt(7D) 							      Devices								   dpt(7D)

NAME
dpt - DPT ServeRAID IV SCSI host bus adapter and RAID adapter driver DESCRIPTION
The dpt driver is a driver for the DPT (Distributed Processing Technology) family of SmartRAID IV SCSI HBA and RAID adapters. The following HBA adapters are supported: PM2024, PM2044UW, PM2044W, PM2124, PM2124W, PM2144UW, and PM2144W. The following RAID adapters are supported: PM3224, PM3224W, PM3334UW, and PM3334W. PRECONFIGURATION
o DPT PM3224 only: Only EPROM 7A and later versions are supported. o DPT PM2024 and PM2124 only: Only EPROM 6D4 and later versions are supported. o Use adapters with SmartROM version 3.B or later versions only. o Be sure that the controller board is installed in a PCI bus-mastering slot. o Disable PCI parity checking if your firmware version is earlier than version 7A, if your system memory is ECC, or if your system does not check parity. Known Problems and Limitations During system boot, a message may be displayed saying a DPT controller driver cannot be installed. This message indicates that the mother- board installed in your system may contain ECC memory or may not check parity. If you see this message is displayed, disable PCI parity checking. Supported Settings o I/O Address: Auto CONFIGURATION
Auto-configuration code determines whether the adapter is present at the configured address and what types of devices are attached to it. The DPT ServeRAID is primarily used as a disk array (system drive) controller. To configure the attached disk arrays, you must configure the controller (using the configuration utilities provided by the hardware manu- facturer) before you boot the Solaris operating environment. You use the configuration utilities to set RAID levels, stripe parameters, cache mechanisms and perform other functions. For more information, see the user manual supplied with your hardware. FILES
/kernel/drv/dpt.conf dpt configuration file /dev/dsk/cndn[s|p]n block device /dev/rdsk/cndn[s|p]n raw device where: cn controller n dn LUN n (0-7) sn UNIX system slice n (0-15) pn fdisk(1M) partition(0) ATTRIBUTES
See attributes(5) for descriptions of the following attributes: +-----------------------------+-----------------------------+ | ATTRIBUTE TYPE | ATTRIBUTE VALUE | |Architecture |x86 | +-----------------------------+-----------------------------+ SEE ALSO
fdisk(1M), attributes(5), cmdk(7D) SunOS 5.10 27 November 2000 dpt(7D)
All times are GMT -4. The time now is 02:45 PM.
Unix & Linux Forums Content Copyright 1993-2022. All Rights Reserved.
Privacy Policy