08-31-2010
It means that the occupant [LUN] isn't visible through the LINK, you need to either look into the cable running or check the zoning in case the cable is OK, and then look for reconfiguration.
10 More Discussions You Might Find Interesting
1. UNIX for Dummies Questions & Answers
HI All,
Suddenly don't know what happened to redhat linux 7.2 any program start then itsn't listing while using ps -ef
ex: ./xyz this xyz program pid not showing in ps-ef
Pls let me know what is the reason for the same.
Thanks a lot in advance
Bache (7 Replies)
Discussion started by: bache_gowda
7 Replies
2. Shell Programming and Scripting
Hi,
I have a shell scripting. This will take 7 digit number in each line and add 7 digit number with next subsequent lines ( normal addition ).
Eg:
0000001
0000220
0001235
0000022
0000023
...........
.........
........
Like this i am having around 1500000 records. After adding... (23 Replies)
Discussion started by: thambi
23 Replies
3. Solaris
Hi,
One of 2 local disks on V480 running solaris 10 and SVM failed.
Now after running metadettach for submirrors on that disk, I want to unconfigure the FAULTY disk using cfgadm -c uncofigure command..and then put new one and configure that.
but surprisingly I don't see local dsk in cfgadm... (17 Replies)
Discussion started by: upengan78
17 Replies
4. Solaris
# cfgadm -al
Ap_Id Type Receptacle Occupant Condition
c0 scsi-bus connected configured unknown
c0::dsk/c0t0d0 CD-ROM connected configured unknown
c1 scsi-bus ... (8 Replies)
Discussion started by: robsonde
8 Replies
5. UNIX for Dummies Questions & Answers
In LINUX(CentOS, RedHat) is there a way to have the banner statement appear before the logon instead of after the logon? In UNIX and Windows the banner appears before a person actually logs on, what I'm seeing in LINUX is that it appears after the login(ftp, telnet, SSH).
Thanks (0 Replies)
Discussion started by: ejjones
0 Replies
6. Solaris
Hi, I`m having a server, that was initially having 2 HBA`s, and dmpnodes were creates with 2 subpaths:
# vxdisk -o alldgs list
DEVICE TYPE DISK GROUP STATUS
c0t0d0s2 auto:none - - online invalid
c0t1d0s2 auto:none - ... (5 Replies)
Discussion started by: masloff
5 Replies
7. Shell Programming and Scripting
Hello everyone, I'm in need of some assistance. I'm currently enrolled in an introductory UNIX shell programming course and, well halfway through the semester, we are receiving our first actual assignment. I've somewhat realized now that I've fallen behind, and I'm working to get caught up, but for... (1 Reply)
Discussion started by: MrMagoo22
1 Replies
8. Solaris
Hot swapping a drive on V240.
So, I do cfgadm -c unconfigure <disk>. Then cfgadm -al reports disk as unconfigured as expected.
format then tells me there is no disk.
BUT, blue light does not come on. Done the exact same command on my V440 and blue light does come on.
V240 Server Admin... (0 Replies)
Discussion started by: psychocandy
0 Replies
9. Shell Programming and Scripting
Hi All,
I am using the below script which has awk command, but it is not returing the expected result. can some pls help me to correct the command.
The below script sample.ksh should give the result if the value of last 4 digits in the variable NM matches with the variable value DAT. The... (7 Replies)
Discussion started by: G.K.K
7 Replies
10. Shell Programming and Scripting
Hi,
when i am trying below script
assume that below values are taken in code
#!/bin/ksh
if
then
echo usage: aNlist.sh QMGR NAME MQREQ
fi
NL=`echo 'dis qmgr'|runmqsc $1|grep REPOSNL|sed 's/.*REPOSNL\(.*\).*/\1/' |cut -d'(' -f2|cut -d')' -f1`
echo 'define nl('$NL_$2')... (25 Replies)
Discussion started by: darling
25 Replies
LEARN ABOUT X11R4
liebert
LIEBERT(8) NUT Manual LIEBERT(8)
NAME
liebert - Driver for Liebert contact-closure UPS equipment
NOTE
This man page only documents the hardware-specific features of the liebert driver. For information about the core driver, see nutupsdrv(8).
SUPPORTED HARDWARE
This driver supports some Liebert UPS equipment with a contact-closure interface. This includes the UPStation GXT2 with their
contact-closure cable. The smart mode ("Multilink") cable is not supported by this driver.
EXTRA ARGUMENTS
This driver does not support any extra settings in the ups.conf(5).
BUGS
This driver does not yet support shutdowns by raising DTR. Be aware that shutdowns are not possible with the stock contact-closure cable.
You may have to build another cable with DTR connected through to the UPS for it to work.
There is no way for this driver to detect the hardware or cable. It will start up successfully even if no UPS is present. This is a
fundamental limitation of any contact-closure driver.
SEE ALSO
The core driver:
nutupsdrv(8)
Internet resources:
The NUT (Network UPS Tools) home page: http://www.networkupstools.org/
Network UPS Tools 05/21/2012 LIEBERT(8)