Software RAID (quick and dirty):
Code:
for i in /dev/md*; do printf '%s: %s\n' $i "$( sudo /sbin/mdadm --detail $i 2>/dev/null | grep 'Raid Level' )"; done

For hardware RAID it depends on the vendor of the RAID card and whether or not the according utilities have been installed.
 

9 More Discussions You Might Find Interesting

1. Slackware

LDAP not getting configured!!!

hi, i m tryin to learn ldap. but its not getting configured. the error msg it shows is: LDAP configure error: BDB/HDB : Berkeley DB version incompatibe. The BDB version i have installed is bdb4.2.52 and the ldap version is openldap-2.3.12. my machine is running on red hat linux 9. Why... (1 Reply)
Discussion started by: mridula
1 Replies

2. UNIX for Dummies Questions & Answers

RAID software vs hardware RAID

Hi Can someone tell me what are the differences between software and hardware raid ? thx for help. (2 Replies)
Discussion started by: presul
2 Replies

3. Red Hat

How to Find what HBA is configured on Linux?

Hi I am working in an environment where there are many redhat physical and virtual machines, mostly Redhat 4. These servers have LUNs attached. The external storage can be EMC, NetApp or Par3. My question is that when Storage Administrator informs that a new LUN has been presented to a... (4 Replies)
Discussion started by: Tirmazi
4 Replies

4. AIX

SCSI PCI - X RAID Controller card RAID 5 AIX Disks disappeared

Hello, I have a scsi pci x raid controller card on which I had created a disk array of 3 disks when I type lspv ; I used to see 3 physical disks ( two local disks and one raid 5 disk ) suddenly the raid 5 disk array disappeared ; so the hardware engineer thought the problem was with SCSI... (0 Replies)
Discussion started by: filosophizer
0 Replies

5. Solaris

Software RAID on top of Hardware RAID

Server Model: T5120 with 146G x4 disks. OS: Solaris 10 - installed on c1t0d0. Plan to use software raid (veritas volume mgr) on c1t2d0 disk. After format and label the disk, still not able to detect using vxdiskadm. Question: Should I remove the hardware raid on c1t2d0 first? My... (4 Replies)
Discussion started by: KhawHL
4 Replies

6. HP-UX

Script to find what netprinters are configured with what model

Following this thread : https://www.unix.com/hp-ux/189023-solved-way-tell-printer-used-configured-print-queue.html This is rwuerth's nice contribution! I had a more complicated script written a long time ago to find out this information, but after realizing due to VBE's post (thank you VBE)... (0 Replies)
Discussion started by: rwuerth
0 Replies

7. Red Hat

RAID Configuration for IBM Serveraid-7k SCSI RAID Controller

Hello, I want to delete a RAID configuration an old server has. Since i haven't the chance to work with the specific raid controller in the past can you please help me how to perform the configuraiton? I downloaded IBM ServeRAID Support CD but i wasn't able to configure the video card so i... (0 Replies)
Discussion started by: @dagio
0 Replies

8. IP Networking

IP not configured is being used to login

Hi have a solaris server with the following IP 192.168.0.85, but anybody can login in using 172.19.0.85, and the ifconfigcommand does not show the 172.19.05 . # ifconfig -a lo0: flags=2001000849<UP,LOOPBACK,RUNNING,MULTICAST,IPv4,VIRTUAL> mtu 8232 index 1 inet 127.0.0.1 netmask... (6 Replies)
Discussion started by: fretagi
6 Replies

9. Linux

Find a process ID,kill it and restart agent

#!/bin/bash #This shell finds the pid of the hawkagent and kills and restarts to put the rulebase into effect output=`ps aux|grep hawkagent` #The set -- below helps to parse the above ps output into words and $2 gives the 2nd word which is pid set -- $output pid=$2 #Checks if pid of hawkagent... (12 Replies)
Discussion started by: samrat dutta
12 Replies
IIR(4)							   BSD Kernel Interfaces Manual 						    IIR(4)

NAME
iir -- Intel Integrated RAID controller and ICP Vortex driver SYNOPSIS
To compile this driver into the kernel, place the following lines in your kernel configuration file: device pci device scbus device iir Alternatively, to load the driver as a module at boot time, place the following line in loader.conf(5): iir_load="YES" DESCRIPTION
The iir driver claims to interface with the Intel integrated RAID controller cards, and all versions of the ICP Vortex controllers (including FC). HARDWARE
Controllers supported by the iir driver include: o Intel RAID Controller SRCMR o Intel Server RAID Controller U3-l (SRCU31a) o Intel Server RAID Controller U3-1L (SRCU31La) o Intel Server RAID Controller U3-2 (SRCU32) o All past and future releases of Intel and ICP RAID Controllers. o Intel RAID Controller SRCU21 (discontinued) o Intel RAID Controller SRCU31 (older revision, not compatible) o Intel RAID Controller SRCU31L (older revision, not compatible) The SRCU31 and SRCU31L can be updated via a firmware update available from Intel. SEE ALSO
cam(4), pass(4), xpt(4), camcontrol(8) AUTHORS
The iir driver is supported and maintained by Achim Leubner <Achim_Leubner@adaptec.com>. This manual page was written by Tom Rhodes <trhodes@FreeBSD.org> and is based on information supplied by the driver authors and the website of Mike Smith <msmith@FreeBSD.org>. BSD
August 8, 2004 BSD
All times are GMT -4. The time now is 07:06 AM.
Unix & Linux Forums Content Copyright 1993-2022. All Rights Reserved.
Privacy Policy