we have a vew boxes using MPIO and they are connected to some virtualization software managing some disk subsystems, offering volumes to the AIX boxes.
Sometimes when a cable has been plugged out for a test or when a real problem occurs, using lspath to show the state of the paths shows correct, that for example 1 path is failed, the other enabled. When the cable is plugged back in again or the problem has been recovered, that path still shows that it is failed. Even waiting some time, this will not recover. No matter what we tried will change that but a reboot of the box. I do not remember exactly if the path being shown as "failed" did still work (I thought I issued a fcstat and there was bytes counting up, not sure though, too long ago) even though the lspath showed.
Did anybody have had any similar experience with MPIO? We thought that since MPIO is some years on the market now, that an obvious problem like not updating the status of a path should be obsolete. So we came to the conclusion that it might be some kind of incompability with our virtualization software.
I never saw something like it on a box using Powerpath.
Additionally, this problem does not happen every time and not on all of the MPIO boxes.
Our boxes are running AIX 5.3 TL11 SP4.
Any hints are welcome.
---------- Post updated at 09:08 AM ---------- Previous update was at 08:54 AM ----------
Here the config of a path from a box that had no problem so far - the other boxes have same parameters for health check etc.:
My product have around 10-15 programs/services running in the sun box, which together completes a task, sequentially. Several instances of the each program/service are running in the unix box, to manage the load and for risk-management reasons. As of now, we dont follow a strict strategy in... (2 Replies)
We are looking at running MPIO for it's redundancy and load balancing benefits. Does anyone know what pieces of software or modules are needed on the VIO server to get load balancing to work. Remember we are using EMC's DMX3500 storage system. We no longer want to use Powerpath. :rolleyes: ... (2 Replies)
Hi folks,
does anybody have a link to a documentation how to implement native MPIO on AIX? We are using EMC PowerPath and Datacore SanSymphony/Cambex for this so far and I wasn't able to find a good description on that topic. All I know so far is that mkpath, chpath and lspath are used to... (3 Replies)
Hi. I am IT manager/developer for a small organization. I have been doing as-needed linux server administration for several years and am by no means an expert. I've built several of my own servers, and our org is currently using hosting services for our servers and I am relatively happy.
We... (3 Replies)
On a particular LPAR, I was running AIX 5.3 TL 3. On Monday I did an update of the LPAR to 5.3 TL 9 SP2. The install was smooth, but then I ran into a problem.
The MPIO driver does not work with LSI's StoreAge (SVM4). I did some looking, and looks like
5.3 TL3 = IBM.MPIO 5.3.0.30
5.3... (0 Replies)
Dear Solaris Experts,
We are upgrading from sun4u to T4 systems and one proposal is to use LDOMs and also zones within LDOMs.
Someone advised using only zones and not LDOMs because the new machines have fewer chips and if a chip or a core fails then it doesn't impact the zones, but impacts... (3 Replies)
This is getting very confusing for me, and appreciate if someone can help.
Platform: Power VM ( Virtual I/O Server)
ioslevel 2.1.3.10-FP23
# oslevel -s
6100-05-00-0000
Storage: IBM DS4300
Two HBAs - Dual Port Fibre Adapter Channels
Each card has two ports , so a total of 4 ports going... (3 Replies)
Hello,
I have some concerns over the disk management of my AIX system.
For example server1
/ > lspv
hdisk0 00fa6d1288c820aa rootvg active
hdisk1 00fa6d1288c8213c vg_2 active