Operating Systems AIX Role of sys admin during power outage in Data center Post 302447023 by mikep9 on Friday 20th of August 2010 02:16:27 PM
Old 08-20-2010
We use UPS batteries to hold a server up long enough to shut them down gracefully if there is a power outage.
 

9 More Discussions You Might Find Interesting

1. Solaris

Raid help for new sys admin

Hi, I have a Sunfire v240 with 4 72GB internal disks (drive 0 is the system disk). Scratch the following ( Revised requirements below) I need to set up a Raid using the remaining 3 disks for a Oracle database, but don't know how to do it (or the size of the database). I don't know if... (1 Reply)
Discussion started by: antalexi
1 Replies

2. What is on Your Mind?

Network Sys Admin

Hi, my name is wesly. I an IT tech at the Junior Level. I have a bachelors degree in Computer Information Systems. I would like to fully become a Unix Sys Admin. Can anyone please tell me what I have to do. Do I have to set up a Unix or Linux server. How about Apache. Please give me clues and tips... (1 Reply)
Discussion started by: wes.lat
1 Replies

3. Solaris

Booting up problem after power outage

hi guys, i'm new so don't bite too hard. having a problem booting up a V210 running sol9 on after a power outage... an init5 was done but not a init0 before the power cut... so now when booting up it gives the ff: SC Alert: Host System has Reset Probing system devices Probing memory... (2 Replies)
Discussion started by: lungsta
2 Replies

4. AIX

Help training for Unix Sys Admin

I have worked on AIX for a number of years now and want to upskill to Sys Admin. My problem is my employer won't give root access etc to their servers so I must find my own way of training. Can anyone suggest a virtual environment I could use to train for AIX sys admin tasks, or suggest an old... (7 Replies)
Discussion started by: jackmeadow
7 Replies

5. Solaris

Sys Admin Certification

Hi, I am planning to get certified in Solaris 10 for my own interest. Although I don't have much experience in sys admin, I have got some background in scripting and some sort of beginner level administration. But I have read in many places that one must have a good amount of experience in sys... (8 Replies)
Discussion started by: King Nothing
8 Replies

6. Linux

Administrator responsibilities, in case of power outage?

Hi guys, I was wondering if you could share some of your knowledge, in the event of a power outage. Let presume you are on duty and you get a call at midnight because half of your cabinets have no power, air conditioning is down and you deal with a ton of 500 error messages on your boxes. ... (9 Replies)
Discussion started by: TECK
9 Replies

7. AIX

System can't boot up after power outage

Hello Forum, I am very newbie with AIX. We have 2 AIX 9111-285 servers. The OS version is 5.3. After the power outage, they did not come up. I try to unplug the power cable and re-connect after 1 minutes but do not help. Both display the same reference code 110000AC on the front panel... (6 Replies)
Discussion started by: lilyn
6 Replies

8. AIX

Automatic Server bootup after power outage?

Hi everyone, We had a power outage few days ago, and I got the servers up and running but I was informed to look into, if there is a way to bring up the servers automatically/defaultly. I was told the windows admin has their server set up where the servers are up automatically if there is a... (11 Replies)
Discussion started by: Adnans2k
11 Replies

9. What is on Your Mind?

OUTAGE: Data Center Problem Resolved.

There was a problem with our data center today, creating a site outage (server unreachable). That problem has been resolved. Basically, it seems to have been a socially engineered denial-of-service attack against UNIX.com; which I stopped as soon as I found out what the problem was. Total... (2 Replies)
Discussion started by: Neo
2 Replies
DETECTUPS(8)						      System Manager's Manual						      DETECTUPS(8)

NAME
detectups - UPS detection/powerd configuration generator SYNOPSIS
/sbin/detectups [tty] DESCRIPTION
detectups monitors the serial port connected to an UPS device and will attempt to determine the method of UPS notification of power outage. It will ask you to remove the power cord from the wall to the UPS, or push the UPS's test button. It will then determine what all has hap- pened and ask to generate a config file based on your UPS and cable configuration. detectups needs to watch a tty with modem control prop- erties. Please refer to the powerd documentation for further information. ARGUMENTS
Serial-Device Some serial port that is not being used by some other device, and does not share an interrupt with any other serial port. /etc/powerd.conf FILES
/etc/powerd.conf powerd configuration file that detectups generates /etc/inittab init is what actually issues the shutdown SEE ALSO
powerd(8), shutdown(8), wall(1), inittab(5). AUTHOR
James Brents <James@nistix.com> (with parts of this man page borrowed from all over the Linux community) DETECTUPS(8)
All times are GMT -4. The time now is 05:04 AM.
Unix & Linux Forums Content Copyright 1993-2022. All Rights Reserved.
Privacy Policy