Hello,
I need explanations about physical disks and physical volumes. What is the difference between these 2 things?
In fact, i am trying to understand what the AIX lspv2command does.
Thank you in advance. (2 Replies)
I was in smit, checking on disc space, etc. and it appears that one of our physical volumes that is part of a large volume group, has no free physical partitions. The server is running AIX 5.1. What would be the advisable step to take in this instance? (9 Replies)
Hello All,
Can anybody please tell me what is the maximum limit of Physical IBM Power Machine which can be handled by single HMC at a single point of time?
Thanks,
Jenish (1 Reply)
Hello,
is it somehow possible to run a x86 Linux OS in a virtual machine in Solaris running on Sparc ? Virtualbox ? Containers ?
I know it would be easier just get a Intel hardware and run the Linux but I might be in a scenario where only Sparc hardware is allowed by corporate policy and still... (6 Replies)
After a memory upgrade all network interfaces are misconfigued. How do i resolve this issue. Below are some out puts.thanks.
ifconfig: plumb: SIOCLIFADDIF: eg000g0:2: no such interface
# ifconfig eg1000g0:2 plumb
ifconfig: plumb: SIOCLIFADDIF: eg1000g0:2: no such interface
# ifconfig... (2 Replies)
Hi,
I am new to unix. I am working on Red Hat Linux and side by side on AIX also. After reading the concepts of Storage, I am now really confused regarding the terminologies
1)Physical Volume
2)Volume Group
3)Logical Volume
4)Physical Partition
Please help me to understand these concepts. (6 Replies)
Hi all,
I am trying to virtualize a running SCO 5.0.6 system with microfocus cobol installed.
I have already managed (thanks to the people in this forum) to install the operating system.
I dont have the cobol installation media anymore. I have copied (using cpio) all directories from... (3 Replies)
Discussion started by: sopela123
3 Replies
LEARN ABOUT DEBIAN
hpialarms
hpialarms(1) OpenHPI hpialarms(1)NAME
hpialarms - A openhpi sample application that shows "Alarm Control" management instruments
SYNOPSIS
hpialarms [-a -b -c -i -m -n -p -o -x]
DESCRIPTION
hpialarms walks the RPT (Resource Present Table) for resouces that have "Alarm Control" management instruments (SAHPI_CTRL_LED).
OPTIONS -c1 sets Critical Alarm on
-c0 sets Critical Alarm off
-m1 sets Major Alarm on
-m0 sets Major Alarm off
-n1 sets Minor Alarm on
-n0 sets Minor Alarm off
-p1 sets Power Alarm on
-p0 sets Power Alarm off
-i5 sets Chassis ID on for 5 sec
-i0 sets Chassis ID off
-a1 sets Disk A fault on
-a0 sets Disk A fault off
-b1 sets Disk B fault on
-b0 sets Disk B fault off
-d[byte] sets raw Alarm byte
-o sets all Alarms off
-x show eXtra debug messages
SAMPLE OUTPUT
hpialarmpanel ver 0.6
RptInfo: UpdateCount = 5, UpdateTime = 8a2dc6c0
rptentry[0] resourceid=1 tag: Mullins
RDR[45]: ctltype=2:1 oem=0 Chassis Identify Control
RDR[48]: ctltype=0:1 oem=10 Front Panel Power Alarm LED state = off
RDR[51]: ctltype=0:1 oem=13 Front Panel Minor Alarm LED state = ON
RDR[46]: ctltype=0:0 oem=0 Cold Reset Control
RDR[49]: ctltype=0:1 oem=11 Front Panel Critical Alarm LED state = off
RDR[50]: ctltype=0:1 oem=12 Front Panel Major Alarm LED state = off
SEE ALSO AUTHORS
Authors of this man page:
Peter D Phan (pdphan@users.sourceforge.net)