Sponsored Content
Special Forums Windows & DOS: Issues & Discussions How To Check Hardware RAID On Windows and Linux Post 302438763 by DukeNuke2 on Tuesday 20th of July 2010 06:03:15 PM
Old 07-20-2010
this depends on the hardware you are using...
 

9 More Discussions You Might Find Interesting

1. Solaris

Hardware RAID

I don't understood why on SPARC-Platforms have not present RAID-Controller ? Sorry for my bad english, but it's crazy always setup software RAID !!! I whanna Hardware RAID and when i can find solution ? (7 Replies)
Discussion started by: jess_t03
7 Replies

2. Solaris

how to hardware RAID 1 on T5120

Hi, I have t5120 sparc and I have 2 146 G drives in the system. I will be installing solaris 10 and also want the system mirrored using Hardware RAID "1" The System did come preinstalled as it comes from sun. I did not do much on it. I booted system using boot cdrom -s gave format... (6 Replies)
Discussion started by: upengan78
6 Replies

3. UNIX for Dummies Questions & Answers

RAID software vs hardware RAID

Hi Can someone tell me what are the differences between software and hardware raid ? thx for help. (2 Replies)
Discussion started by: presul
2 Replies

4. UNIX for Advanced & Expert Users

check external hardware connected to linux/solaris machines

hello, I'm planning to do inventory of all our servers but this time it's more on physical. Meaning I would like to check all hardware connected to it (external only like storage, power support) including the count Would like to get perhaps its serial nr..(linux and solaris different servers... (2 Replies)
Discussion started by: lhareigh890
2 Replies

5. Solaris

how to check for hardware layered raid in solaris 10 ?

hi all, will command metastats tell whether there is hardware layered raid ? i intend to do patching and plug out one of the disks in case the one inside encountered issues. (1 Reply)
Discussion started by: Exposure
1 Replies

6. Hardware

Sun T3-1 hardware RAID

Hi all I've just received my T3-1. It has 8 disks and I would like to configure RAID1 on the disks. The Sun documentation states that you can either use the OpenBoot PROMP utility called Fcode or you can use software via the Solaris OS. The documentation doesn't make it clear if: 1. The... (6 Replies)
Discussion started by: soliberus
6 Replies

7. Solaris

Software RAID on top of Hardware RAID

Server Model: T5120 with 146G x4 disks. OS: Solaris 10 - installed on c1t0d0. Plan to use software raid (veritas volume mgr) on c1t2d0 disk. After format and label the disk, still not able to detect using vxdiskadm. Question: Should I remove the hardware raid on c1t2d0 first? My... (4 Replies)
Discussion started by: KhawHL
4 Replies

8. Solaris

Hardware raid patching

Dear All , we have hardware raid 1 implemented on Solaris Disks. We need to patch the Servers. Kindly let me know how to patch hardware raid implemented Servers. Thanks... Rj (7 Replies)
Discussion started by: jegaraman
7 Replies

9. Solaris

Hardware RAID using three disks

Dear All , Pl find the below command , # raidctl -l Controller: 1 Volume:c1t0d0 Disk: 0.0.0 Disk: 0.1.0 Disk: 0.3.0 # raidctl -l c1t0d0 Volume Size Stripe Status Cache RAID Sub Size ... (10 Replies)
Discussion started by: jegaraman
10 Replies
vxr5check(1M)															     vxr5check(1M)

NAME
vxr5check - verify RAID-5 volume parity SYNOPSIS
/etc/vx/bin/vxr5check [-i | -v] [-g diskgroup] volume DESCRIPTION
The vxr5check utility compares the parity of each stripe of a RAID-5 volume specified by volume. vxr5check reads the data for each stripe, generates the parity for this stripe, and compares this parity with the existing parity. vxr5check can be run against the entire RAID-5 volume, or incrementally on RAID-5 stripe boundaries, by specifying the -i option. OPTIONS
-g diskgroup Specifies the Veritas Volume Manager (VxVM) disk group name for the RAID-5 volume name for verification. If this option is not specified, the default disk group is determined using the rules given in the vxdg(1M) manual page. -i Verifies the RAID-5 volume incrementally per stripes. If a parity mismatch is found, that stripe location is displayed. -v Verbose output for the incremental vxr5check verification. The verbose option outputs each stripe number that is being verified. OUTPUT FORMAT
In verbose mode and incremental mode, summary reports for each stripe of the RAID-5 volume are printed in output records. If an error is returned for a stripe, then an error message and stripe number are displayed. In non-verbose mode, if an error is returned, an error mes- sage is displayed. If a parity mismatch error is determined on a stripe, vxr5check exits on that stripe and does not continue for the remaining stripes in the RAID-5 volume. FILES
/usr/lib/vxvm/bin/vxr5vrfy The utility that vxr5check calls to perform RAID-5 parity verification operations for the specified RAID-5 volume. EXIT CODES
The vxr5check utility exits with a non-zero status if the attempted operation fails. A non-zero exit code is not a complete indicator of the problems encountered, but rather denotes the first condition that prevented further execution of the utility. See vxintro(1M) for a list of standard exit codes. NOTES
Do not run vxr5check on a volume that is in degraded mode. SEE ALSO
vxevac(1M), vxintro(1M), vxmend(1M), vxvol(1M) VxVM 5.0.31.1 24 Mar 2008 vxr5check(1M)
All times are GMT -4. The time now is 03:41 AM.
Unix & Linux Forums Content Copyright 1993-2022. All Rights Reserved.
Privacy Policy