Sponsored Content
Operating Systems Solaris Help needed to find out the disk controller for veritas disks Post 302437743 by kingston on Friday 16th of July 2010 04:25:00 AM
Old 07-16-2010
thanks...exactly this is what i want....

how can i mark this thread as solved?
 

10 More Discussions You Might Find Interesting

1. Solaris

Controller target disk?

Hi, I am a newbie to Solaris. I want to know how to find out the controller target and disk number on a SunFire V890 box that has 6X72GB disks. The probe-scsi output is as shown below: /pci@8,600000/SUNW,qlc@2 LiD HA LUN --- Port WWN --- ----- Disk description ----- 0 0 0 ... (1 Reply)
Discussion started by: sudhir_shet
1 Replies

2. SCO

driver needed for hp smartarry p200i sas raid controller

recently we have purchased hp proliant ml350 g5 server and configured raid 5 with hp smartarray p200i sas controller.but i could not found any sas raid controller hp smartarry p200i driver for sco unix 5.0.7 :(.i searched on hp support site,but no use.any one can help. (3 Replies)
Discussion started by: prakrithi
3 Replies

3. Solaris

RAID controller needed for SVM?

hi this may be a very stupid question, but im quite new to Solaris (gonna buid my first system, Solaris 10 on x86 system, connected to other windows systems in a home network) i wanna put a RAID 5 system in there to back up my other systems at home; iv read that its really so easy with SVM to... (4 Replies)
Discussion started by: Landser
4 Replies

4. SCO

Warning HD: no root disk controller was found

hi... i hav a problem to install sco unix while installing sco unix 5.0.5 in acer altos with hardware raid am getting error "Warning HD: no root disk controller was found system error 5: while getting fs type flushing controller: DAC960PRL cache done." i hav use the following... (18 Replies)
Discussion started by: mselvaprakash
18 Replies

5. SCO

Change Disk controller in SCO 6.0.0

So today I tried to upgrade a customer from a Proliant with an HPSAS controller to an Intel server with a MEGASAS controller. First, I downloaded the megasas driver from SCO and installed it on the old system. Then I created a new Microlite Edge emergency boot cd with the new driver on it. I... (2 Replies)
Discussion started by: jgt
2 Replies

6. AIX

SCSI PCI - X RAID Controller card RAID 5 AIX Disks disappeared

Hello, I have a scsi pci x raid controller card on which I had created a disk array of 3 disks when I type lspv ; I used to see 3 physical disks ( two local disks and one raid 5 disk ) suddenly the raid 5 disk array disappeared ; so the hardware engineer thought the problem was with SCSI... (0 Replies)
Discussion started by: filosophizer
0 Replies

7. Solaris

Changed disk controller -> drops into GRUB?!

I changed disk controller. Unplugged every disk, inserted another controller card, an IBM M1015. The disks are recognized in BIOS, and the controller card's BIOS shows up. But after that, I drop into GRUB and a prompt. That is all. How shall I solve this problem? I am thinking of booting from... (2 Replies)
Discussion started by: kebabbert
2 Replies

8. Solaris

Disk controller reassignment

Hi The scenario in the oracle t4-1 hardware with solaris 10 is as follows: 1. The initial install on the server was performed with an incorrect disk layout. 2. New disks were ordered and slot into the server. 3. The disks are allocated a controller and a disk number based on the disk or... (13 Replies)
Discussion started by: kerrygold
13 Replies

9. UNIX for Beginners Questions & Answers

How to extend a disk in veritas volume manager in veritas cluster?

Hi Experts, I wanted to extend a veritas file system which is running on veritas cluster and mounted on node2 system. #hastatus -sum -- System State Frozen A node1 running 0 A node2 running 0 -- Group State -- Group System Probed ... (1 Reply)
Discussion started by: Skmanojkum
1 Replies

10. Solaris

Disks are not visible in Veritas Volume manager

Hi I have created a new setup for VCS for doing some testing on virtual box. After creating 3 Solaris 10 machine (147148-26) with VCS. Here I have used one machine as ISCSI Storage. VCS Version is bash-3.2# /opt/VRTS/bin/haclus -value EngineVersion 6.0.10.0 bash-3.2# bash-3.2# pkginfo... (4 Replies)
Discussion started by: hb00
4 Replies
pfto(7) 						 Miscellaneous Information Manual						   pfto(7)

NAME
pfto - Powerfail Timeout DESCRIPTION
HP-UX SCSI disk device drivers have a timeout facility that detects non-responding disks. VxVM uses this mechanism in its Powerfail Time- out (pfto) feature. You can specify a timeout value for individual VxVM disks using the vxdisk command (see the EXAMPLES section below). If a disk fails to respond in the specified timeout period, the driver receives a timer interrupt. pfto values are persistent across reboots, that is, after the pfto value is set, it remains in effect until you explicitly change it. If dynamic multipathing is enabled, the pfto value set on a disk applies to each path of a multipath disk device. The pfto value is in seconds. If pfto is not specified, or is zero, the timeout period is 30 seconds. Both the vxdisk and vxprint commands display the current pfto value for a disk. EXAMPLES
Use the following command to set the value of pfto to 30 seconds on disk01: vxdisk -g rootdg set disk01 pfto=30 Use either of the following commands to display the pfto value on the VxVM disk disk01: vxdisk list disk01 vxprint -l disk01 EXIT CODES
Setting the pfto value on a non-VxVM disk returns an error. SEE ALSO
vxdisk(1M), vxprint(1M) VxVM 5.0.31.1 24 Mar 2008 pfto(7)
All times are GMT -4. The time now is 09:26 PM.
Unix & Linux Forums Content Copyright 1993-2022. All Rights Reserved.
Privacy Policy