Sponsored Content
Operating Systems Solaris Help needed to find out the disk controller for veritas disks Post 302437743 by kingston on Friday 16th of July 2010 04:25:00 AM
Old 07-16-2010
thanks...exactly this is what i want....

how can i mark this thread as solved?
 

10 More Discussions You Might Find Interesting

1. Solaris

Controller target disk?

Hi, I am a newbie to Solaris. I want to know how to find out the controller target and disk number on a SunFire V890 box that has 6X72GB disks. The probe-scsi output is as shown below: /pci@8,600000/SUNW,qlc@2 LiD HA LUN --- Port WWN --- ----- Disk description ----- 0 0 0 ... (1 Reply)
Discussion started by: sudhir_shet
1 Replies

2. SCO

driver needed for hp smartarry p200i sas raid controller

recently we have purchased hp proliant ml350 g5 server and configured raid 5 with hp smartarray p200i sas controller.but i could not found any sas raid controller hp smartarry p200i driver for sco unix 5.0.7 :(.i searched on hp support site,but no use.any one can help. (3 Replies)
Discussion started by: prakrithi
3 Replies

3. Solaris

RAID controller needed for SVM?

hi this may be a very stupid question, but im quite new to Solaris (gonna buid my first system, Solaris 10 on x86 system, connected to other windows systems in a home network) i wanna put a RAID 5 system in there to back up my other systems at home; iv read that its really so easy with SVM to... (4 Replies)
Discussion started by: Landser
4 Replies

4. SCO

Warning HD: no root disk controller was found

hi... i hav a problem to install sco unix while installing sco unix 5.0.5 in acer altos with hardware raid am getting error "Warning HD: no root disk controller was found system error 5: while getting fs type flushing controller: DAC960PRL cache done." i hav use the following... (18 Replies)
Discussion started by: mselvaprakash
18 Replies

5. SCO

Change Disk controller in SCO 6.0.0

So today I tried to upgrade a customer from a Proliant with an HPSAS controller to an Intel server with a MEGASAS controller. First, I downloaded the megasas driver from SCO and installed it on the old system. Then I created a new Microlite Edge emergency boot cd with the new driver on it. I... (2 Replies)
Discussion started by: jgt
2 Replies

6. AIX

SCSI PCI - X RAID Controller card RAID 5 AIX Disks disappeared

Hello, I have a scsi pci x raid controller card on which I had created a disk array of 3 disks when I type lspv ; I used to see 3 physical disks ( two local disks and one raid 5 disk ) suddenly the raid 5 disk array disappeared ; so the hardware engineer thought the problem was with SCSI... (0 Replies)
Discussion started by: filosophizer
0 Replies

7. Solaris

Changed disk controller -> drops into GRUB?!

I changed disk controller. Unplugged every disk, inserted another controller card, an IBM M1015. The disks are recognized in BIOS, and the controller card's BIOS shows up. But after that, I drop into GRUB and a prompt. That is all. How shall I solve this problem? I am thinking of booting from... (2 Replies)
Discussion started by: kebabbert
2 Replies

8. Solaris

Disk controller reassignment

Hi The scenario in the oracle t4-1 hardware with solaris 10 is as follows: 1. The initial install on the server was performed with an incorrect disk layout. 2. New disks were ordered and slot into the server. 3. The disks are allocated a controller and a disk number based on the disk or... (13 Replies)
Discussion started by: kerrygold
13 Replies

9. UNIX for Beginners Questions & Answers

How to extend a disk in veritas volume manager in veritas cluster?

Hi Experts, I wanted to extend a veritas file system which is running on veritas cluster and mounted on node2 system. #hastatus -sum -- System State Frozen A node1 running 0 A node2 running 0 -- Group State -- Group System Probed ... (1 Reply)
Discussion started by: Skmanojkum
1 Replies

10. Solaris

Disks are not visible in Veritas Volume manager

Hi I have created a new setup for VCS for doing some testing on virtual box. After creating 3 Solaris 10 machine (147148-26) with VCS. Here I have used one machine as ISCSI Storage. VCS Version is bash-3.2# /opt/VRTS/bin/haclus -value EngineVersion 6.0.10.0 bash-3.2# bash-3.2# pkginfo... (4 Replies)
Discussion started by: hb00
4 Replies
PTHREAD_DETACH(3)					   BSD Library Functions Manual 					 PTHREAD_DETACH(3)

NAME
pthread_detach -- detach a thread LIBRARY
POSIX Threads Library (libpthread, -lpthread) SYNOPSIS
#include <pthread.h> int pthread_detach(pthread_t thread); DESCRIPTION
The pthread_detach() function is used to indicate to the implementation that storage for the thread thread can be reclaimed when the thread terminates. If thread has not terminated, pthread_detach() will not cause it to terminate. The effect of multiple pthread_detach() calls on the same target thread is unspecified. RETURN VALUES
If successful, the pthread_detach() function will return zero. Otherwise an error number will be returned to indicate the error. Note that the function does not change the value of errno as it did for some drafts of the standard. These early drafts also passed a pointer to pthread_t as the argument. Beware! ERRORS
The pthread_detach() function will fail if: [EINVAL] The implementation has detected that the value specified by thread does not refer to a joinable thread. [ESRCH] No thread could be found corresponding to that specified by the given thread ID, thread. SEE ALSO
pthread_join(3) STANDARDS
The pthread_detach() function conforms to ISO/IEC 9945-1:1996 (``POSIX.1''). BSD
April 4, 1996 BSD
All times are GMT -4. The time now is 05:31 AM.
Unix & Linux Forums Content Copyright 1993-2022. All Rights Reserved.